886 research outputs found

    The Rise and Fall of Qigong

    Get PDF
    This capstone engages the history qigong, a Chinese method of spiritual and bodily cultivation. Although similar Daoist practices have existed for thousands of years, the term qigong was invented by the Chinese military in the 1950s. Qigong exploded in popularity in China from the early 1980s to the late 90s. The Chinese state promoted, appropriated, regulated, and ultimately suppressed qigong. On one hand, the Chinese Communist Party wanted to measure and order qigong according to orthodox scientific and political principles, thus processing and controlling the explosion of spirituality known as “Qigong Fever.” Yet on the other hand, both within and outside the state, many people witnessed the miraculous power of qigong, came to believe in it deeply, and wanted its spiritual and religious elements to thrive. The interplay of these two approaches—to measure and control vs. to experience and believe—drove the state’s interaction with qigong, fueling qigong’s rise yet causing its fall. Ultimately, the religious elements of qigong operated on their own terms and proved impossible to control

    Engineering parameters of an induced draft aerator with foam recycle

    Get PDF

    The Application of Principal Component Analysis Using Fixed Eigenvectors to the Infrared Thermographic Inspection of the Space Shuttle Thermal Protection System

    Get PDF
    The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the good material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued when a fixed set of eigenvectors is used to process the thermal data from the RCC materials. These eigen vectors can be generated either from an analytic model of the thermal response of the material under examination, or from a large cross section of experimental data. This paper will provide the details of the analytic model; an overview of the PCA process; as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens. Details of a system that has been developed to allow insitu inspection of a majority of shuttle RCC components will be presented along with the acceptance test results for this system. Additionally, the results of applying this technology to the Space Shuttle Discovery after its return from flight will be presented

    Thermal method for depth of damage determination in insulating materials

    Get PDF
    Impact damage often may produce little visible surface damage, yet extensive subsurface delaminations, greatly reducing the load carrying capacity of the composite part [1]. For large composite structures typical of aerospace applications, thermal NDE techniques have been shown to provide quantitative information regarding the area and depth of hidden damage in composite samples [2] [3]. For a quantitative assessment of damage, where a noncontacting method capable of imaging large areas at a time is required, thermal techniques have some advantages

    Wire Crimp Termination Verification Using Ultrasonic Inspection

    Get PDF
    The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed

    Marking Electrical Wiring With Condition Indicators

    Get PDF
    A method is provided for marking electrical Wiring with condition indicators. One or more markers are added to one or both of the insulative material and a surface of an electrical conductor such that it bonds thereto. Each marker is capable of emanating into a surrounding atmospheric environment as a gaseous effluent in response to a specific condition experienced by the electrical conductor

    Ultrasonic Inspection to Quantify Failure Pathologies of Crimped Electrical Connections

    Get PDF
    Previous work has shown that ultrasonic inspection provides a means of assessing electrical crimp quality that ensures the electrical and mechanical integrity of an initial crimp before the installation process is completed. The amplitude change of a compressional ultrasonic wave propagating at right angles to the wire axis and through the junction of a crimp termination was shown to correlate with the results of destructive pull tests, which is a standard for assessing crimp wire junction quality. Of additional concern are crimps made at high speed assembly lines for wiring harnesses, which are used for critical applications, such as in aircraft. During high-speed assembly it is possible that many faulty crimps go undetected until long after assembly, and fail in service. The position and speed of the crimping jaw become factors as the high-speed crimp is formed. The work presented in this paper is designed to cover the more difficult and more subtle area of high-speed crimps by taking into account the rate change of the measurements. Building on the previous work, we present an analysis methodology, based on transmitted ultrasonic energy and timing of the first received pulse that is shown to correlate to the gauge of the crimp/ferrule combination and the position of the crimping jaw. Results demonstrating the detectability of a number of the crimp failure pathologies, such as missing strands, partially inserted wires and incomplete crimp compression, are presented. The ability of this technique to estimate crimp height, a mechanical measure of crimp quality, is discussed

    Wind-tunnel evaluation of an advanced main-rotor blade design for a utility-class helicopter

    Get PDF
    An investigation was conducted in the Langley Transonic Dynamics Tunnel to evaluate differences between an existing utility-class main-rotor blade and an advanced-design main-rotor blade. The two rotor blade designs were compared with regard to rotor performance oscillatory pitch-link loads, and 4-per-rev vertical fixed-system loads. Tests were conducted in hover and over a range of simulated full-scale gross weights and density altitude conditions at advance ratios from 0.15 to 0.40. Results indicate that the advanced blade design offers performance improvements over the baseline blade in both hover and forward flight. Pitch-link oscillatory loads for the baseline rotor were more sensitive to the test conditions than those of the advanced rotor. The 4-per-rev vertical fixed-system load produced by the advanced blade was larger than that produced by the baseline blade at all test conditions
    • …
    corecore