258 research outputs found

    Non-invasive estimation of QLV from the standard 12-lead ECG in patients with left bundle branch block

    Get PDF
    Background: Cardiac resynchronization therapy (CRT) is a treatment for patients with heart failure and electrical dyssynchrony, i.e., left bundle branch block (LBBB) ECG pattern. CRT resynchronizes ventricular contraction with a right ventricle (RV) and a left ventricle (LV) pacemaker lead. Positioning the LV lead in the latest electrically activated region (measured from Q wave onset in the ECG to LV sensing by the left pacemaker electrode [QLV]) is associated with favorable outcome. However, optimal LV lead placement is limited by coronary venous anatomy and the inability to measure QLV non-invasively before implantation. We propose a novel non-invasive method for estimating QLV in sinus-rhythm from the standard 12-lead ECG. Methods: We obtained 12-lead ECG, LV electrograms and LV lead position in a standard LV 17-segment model from procedural recordings from 135 standard CRT recipients. QLV duration was measured post-operatively. Using a generic heart geometry and corresponding forward model for ECG computation, the electrical activation pattern of the heart was fitted to best match the 12-lead ECG in an iterative optimization procedure. This procedure initialized six activation sites associated with the His-Purkinje system. The initial timing of each site was based on the directions of the vectorcardiogram (VCG). Timing and position of the sites were then changed iteratively to improve the match between simulated and measured ECG. Noninvasive estimation of QLV was done by calculating the time difference between Q-onset on the computed ECG and the activation time corresponding to centroidal epicardial activation time of the segment where the LV electrode is positioned. The estimated QLV was compared to the measured QLV. Further, the distance between the actual LV position and the estimated LV position was computed from the generic ventricular model. Results: On average there was no difference between QLV measured from procedural recordings and non-invasive estimation of QLV ( [Formula: see text] ). Median distance between actual LV pacing site and the estimated pacing site was 18.6 mm (IQR 17.3 mm). Conclusion: Using the standard 12-lead ECG and a generic heart model it is possible to accurately estimate QLV. This method may potentially be used to support patient selection, optimize implant procedures, and to simulate optimal stimulation parameters prior to pacemaker implantation

    Radiofrequency Ablation as Initial Therapy in Paroxysmal Atrial Fibrillation

    Get PDF
    Background There are limited data comparing radiofrequency catheter ablation with antiarrhythmic drug therapy as first-line treatment in patients with paroxysmal atrial fibrillation. Methods We randomly assigned 294 patients with paroxysmal atrial fibrillation and no history of antiarrhythmic drug use to an initial treatment strategy of either radiofrequency catheter ablation (146 patients) or therapy with class IC or class III antiarrhythmic agents (148 patients). Follow-up included 7-day Holter-monitor recording at 3, 6, 12, 18, and 24 months. Primary end points were the cumulative and per-visit burden of atrial fibrillation (i.e., percentage of time in atrial fibrillation on Holter-monitor recordings). Analyses were performed on an intention-to-treat basis. Results There was no significant difference between the ablation and drug-therapy groups in the cumulative burden of atrial fibrillation (90th percentile of arrhythmia burden, 13% and 19%, respectively; P = 0.10) or the burden at 3, 6, 12, or 18 months. At 24 months, the burden of atrial fibrillation was significantly lower in the ablation group than in the drug-therapy group (90th percentile, 9% vs. 18%; P = 0.007), and more patients in the ablation group were free from any atrial fibrillation (85% vs. 71%, P = 0.004) and from symptomatic atrial fibrillation (93% vs. 84%, P = 0.01). One death in the ablation group was due to a procedure-related stroke; there were three cases of cardiac tamponade in the ablation group. In the drug-therapy group, 54 patients (36%) underwent supplementary ablation. Conclusions In comparing radiofrequency ablation with antiarrhythmic drug therapy as first-line treatment in patients with paroxysmal atrial fibrillation, we found no significant difference between the treatment groups in the cumulative burden of atrial fibrillation over a period of 2 years. (Funded by the Danish Heart Foundation and others; MANTRA-PAF ClinicalTrials.gov number, NCT00133211.
    • …
    corecore