62 research outputs found
Release of Palladium from Biomechanical Prostheses in Body Fluids Can Induce or Support PD-Specific IFNγ T Cell Responses and the Clinical Setting of a Palladium Hypersensitivity:
The increased use of Palladium (Pd) for biomedical applications, which has more than doubled in the last ten years, appears to be associated with an increased frequency of adverse reactions to Pd. The aim of this study is to investigate the relationship between the implant of a biomechanical apparatus containing Pd and the setting of a hypersensitivity to Pd by determining the levels of the metal released in biological fluids, assessing the effects of Pd on peripheral blood mononuclear cell (PBMC) cytokine production and exploring the clinical setting of skin sensitization. Of a total of 3,093 subjects examined in 2006, sensitization to Pd alone or in association with nickel (Ni) was observed in 1.6% and 13.03% of the individuals, respectively. Of these, a group of six subjects positive to Pd and negative to Ni at patch testing were selected on the basis of the oral clinical symptoms in order to measure both the levels of Pd in biological fluids and the degradation of the dental prostheses. Specific Pd measurements were carried out on salivary fluid, urine and serum samples by High Resolution Inductively Coupled Plasma-Mass Spectrometry. In addition, the degradation of the dental prostheses was assessed by both a "leaching test" and an analysis of the micro morphology of orthodontic prostheses. The induction of IFN-γ production by Pd was assessed in PBMC by the ELISpot assay. Skin sensitization to Pd was evaluated by patch testing and clinical examination. Ten healthy subjects were comparatively tested as controls. We found a specific induction of an IFN-γ response by Pd in PBMC collected from all the subjects positive to Pd at patch testing. On the contrary, control subjects did not show any response to Pd as assessed by IFN-γ ELISpot assay or by skin testing. Remarkably, the levels of Pd in all biological samples (saliva, sera, urine) were significantly higher in Pd-sensitized patients than in those collected from controls, reaching the highest concentrations in the urine. The leaching studies gave additional evidence that the dental appliances can release measurable levels of Pd in saliva. Oral clinical symptoms in patients with Pd dental prostheses were associated with measurable levels of Pd in the biological fluids, the induction of Pd-specific IFN-γ responses in PBMC and the clinical evidence of skin sensitization to Pd. These data suggest that dental appliances may represent an active source of Pd in the body, and this, in turn, can favour the clinical setting of a hypersensitivity to this metal
Nickel, palladium and rhodium induced IFN-gamma and IL-10 production as assessed by in vitro ELISpot-analysis in contact dermatitis patients
http://deepblue.lib.umich.edu/bitstream/2027.42/61297/1/Bordignonetal,Nickel,palladiaumandrhodiuminduced.pd
AIDS-Kaposi Sarcoma and Classic Kaposi Sarcoma: are different ultrasound patterns related to different variants?
<p>Abstract</p> <p>Background</p> <p>Kaposi Sarcoma (KS) is a malignancy of endothelial skin cells with multifocal localization on the skin, lymph nodes and visceral organs. Although all clinical variants are associated with HHV-8 infection, specific differences in the clinical onset and in the natural history of AIDS-KS and Classic-KS have been described. The present randomised prospective-observational study aimed to investigate whether the ultrasound pattern and color Doppler flow imaging of vascularisation of skin lesions of patients with Classic KS (CKS) or AIDS-KS could provide useful information to the evaluation of clinical activity of the disease.</p> <p>Methods</p> <p>Cutaneous lesions of 24 patients with histologically confirmed KS were investigated using very high frequency ultrasound probes; 16 patients had CKS and 8 had AIDS-KS. HHV-8 infection was confirmed in all patients by investigating the specific humoral response to viral antigens. Immunological and virological parameters were also assessed to monitor HIV or HHV-8 viral infection. For each patient, a target skin lesion was selected on the basis of size (diameter from 0.4 to 2 cm). Each lesion was analyzed in terms of size, depth and color Doppler pattern.</p> <p>Results</p> <p>The B-mode ultrasound patterns of skin lesions did not differ when comparing CKS patients to AIDS-KS patients, whereas the color Doppler signal, which is associated with vascular activity, was detected in the KS lesions of 6/8 AIDS-KS patients (75.0%) and in 2/16 CKS (16,7%); the latter two patients showed a clinically progressive and extensive disease stage (IV B).</p> <p>Conclusions</p> <p>Our preliminary results suggest that small cutaneous KS lesions - in both CKS and AIDS-KS patients- display similar B-mode ultrasound patterns ( hypoechoic, well defined, superficial lesions). However, the color Doppler signal, which is associated with endothelial activity and angiogenesis, which play a substantial role in KS progression, could constitute a useful tool for evaluating disease activity.</p
HIV and decreased risk of multiple sclerosis: role of low CD4+ lymphocyte count and male prevalence
In this retrospective case-control study, we compared the number of circulating lymphocyte subsets among 31 healthy controls, 18 naïve and 40 antiretroviral-treated HIV patients, 28 untreated and 18 treated relapsing-remitting multiple sclerosis (MS) patients. Lymphocyte subsets were no different between untreated MS patients and controls. Untreated and treated MS had a lower CD8+ count and a higher CD4+ number compared to untreated and treated HIV patients except similar CD4+ number between treated MS and HIV patients. CD4/CD8 ratio was lower in female HIV non-responders and in relapsing MS women compared, respectively, to female HIV responders and remitting MS women, and there were no differences in men
Evaluation of Recombinant Antigen-Based Assays for Diagnosis of Bullous Autoimmune Diseases
The diagnosis of autoimmune bullous diseases is based on clinical observation and on the presence of autoantibodies directed to molecules involved in the adhesion systems of the skin. Immunofluorescence assays are the currently accepted method for detection of autoantibodies; such assays depend greatly on the skill of operators and are difficult to standardize. Recombinant desmoglein-1 (Dsg1), Dsg3, and BP180 peptides, the main autoantigens in pemphigus or bullous pemphigoid, have been used to develop new quantitative enzyme immunoassays (EIA) for the detection of specific antibodies. The present study was undertaken to evaluate the sensitivity and specificity of these immunoassays and to determine the correlation between the results and the clinical aspects of diseases. Serum samples from patients with pemphigus vulgaris, pemphigus foliaceus, bullous pemphigoid, or mucous membrane pemphigoid, from healthy individuals, and from patients with unrelated autoimmune conditions were tested. Anti-desmoglein reactivity was detected in all the patients with pemphigus and in none of the controls. Patients with the more benign form of cutaneous disease had anti-Dsg1 antibodies, while patients with deeper cutaneous lesions or with mucosal involvement had anti-Dsg3 reactivity also, or exclusively. The BP180-based assay was positive for 66.6% of patients with bullous pemphigoid and for none of the patients with mucous membrane pemphigoid, and no reactivity was detected in the control sera. In conclusion, the anti-Dsg1 and anti-Dsg3 assays are useful in the diagnosis of pemphigus and provide information on the clinical phenotype of the disease. However, the sensitivity of EIA for detection of autoantibodies in bullous pemphigoid should be improved by the use of additional antigens or epitopes
Long term follow up of peripheral lymphocyte subsets in a cohort of multiple sclerosis patients treated with natalizumab.
Natalizumab, an anti-alpha4 integrin monoclonal antibody inhibiting the adhesion of lymphocytes to the endothelium, is a widely accepted drug treatment for relapsing–remitting multiple sclerosis (RRMS). A peripheral increase of T and B lymphocytes has already been observed as an early treatment effect. This retrospective observational study was aimed to evaluate the peripheral lymphocyte subsets during a long-term treatment follow-up. We included 23 RRMS patients treated with natalizumab for at least 24–48 months who had pretreatment lymphocyte evaluation. Baseline values of lymphocyte subsets and CD4/CD8 ratio did not differ significantly from the 23 matched healthy subjects. The periodic (every 3–6 months) assessment of immune cell subsets was performed by flow cytometry on peripheral blood collected before drug injection. Therapy with natalizumab was confirmed to be effective during the observational period. For all patients, the increase in lymphocytes during natalizumab therapy compared to baseline at every assessment was significantly higher compared to that of overall white blood cells (2·1-and 1·3-fold, respectively, P < 0·0001). Both T cell subsets were proportionally modified and the CD4/CD8 ratio did not change significantly, while B cells increased significantly compared to T and NK cells (3·2-, 1·88-and 1·92-fold, respectively, P < 0·0001). These changes remained constant throughout the 25–48-month period of therapy. In conclusion, effective natalizumab treatment of RRMS patients was associated with the persistence of its biological effects through a stable increase of peripheral lymphocytes, mainly B cells, and an unchanged proportion of T cell subsets in long-term follow-up
- …