79 research outputs found

    Regional contrast agent quantification in a mouse model of myocardial infarction using 3D cardiac T1 mapping

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Quantitative relaxation time measurements by cardiovascular magnetic resonance (CMR) are of paramount importance in contrast-enhanced studies of experimental myocardial infarction. First, compared to qualitative measurements based on signal intensity changes, they are less sensitive to specific parameter choices, thereby allowing for better comparison between different studies or during longitudinal studies. Secondly, T<sub>1 </sub>measurements may allow for quantification of local contrast agent concentrations. In this study, a recently developed 3D T<sub>1 </sub>mapping technique was applied in a mouse model of myocardial infarction to measure differences in myocardial T<sub>1 </sub>before and after injection of a liposomal contrast agent. This was then used to assess the concentration of accumulated contrast agent.</p> <p>Materials and methods</p> <p>Myocardial ischemia/reperfusion injury was induced in 8 mice by transient ligation of the LAD coronary artery. Baseline quantitative T<sub>1 </sub>maps were made at day 1 after surgery, followed by injection of a Gd-based liposomal contrast agent. Five mice served as control group, which followed the same protocol without initial surgery. Twenty-four hours post-injection, a second T<sub>1 </sub>measurement was performed. Local ΔR<sub>1 </sub>values were compared with regional wall thickening determined by functional cine CMR and correlated to <it>ex vivo </it>Gd concentrations determined by ICP-MS.</p> <p>Results</p> <p>Compared to control values, pre-contrast T<sub>1 </sub>of infarcted myocardium was slightly elevated, whereas T<sub>1 </sub>of remote myocardium did not significantly differ. Twenty-four hours post-contrast injection, high ΔR<sub>1 </sub>values were found in regions with low wall thickening values. However, compared to remote tissue (wall thickening > 45%), ΔR<sub>1 </sub>was only significantly higher in severe infarcted tissue (wall thickening < 15%). A substantial correlation (<it>r </it>= 0.81) was found between CMR-based ΔR<sub>1 </sub>values and Gd concentrations from <it>ex vivo </it>ICP-MS measurements. Furthermore, regression analysis revealed that the effective relaxivity of the liposomal contrast agent was only about half the value determined <it>in vitro</it>.</p> <p>Conclusions</p> <p>3D cardiac T<sub>1 </sub>mapping by CMR can be used to monitor the accumulation of contrast agents in contrast-enhanced studies of murine myocardial infarction. The contrast agent relaxivity was decreased under <it>in vivo </it>conditions compared to <it>in vitro </it>measurements, which needs consideration when quantifying local contrast agent concentrations.</p

    Novel strategies for mouse cardiac MRI - Better Stronger Faster

    No full text
    Mouse models of cardiac disease are an important tool to gain understanding of the pathophysiological processes related to the heart, as well as for the development of new treatment strategies. In this respect, Magnetic Resonance Imaging (MRI) has become the gold standard imaging modality, because it combines high spatial resolution imaging with a large variety of soft tissue contrast weightings that can be related to the presence of diseased tissue. In addition, (targeted) MRI contrast agents can be employed to visualize different processes on the molecular level, for example in relation to myocardial infarction and the subsequent cardiac remodeling process. The specificity to discriminate healthy from diseased tissue as well as the sensitivity for detection of MR contrast agents is strongly affected by the specific MRI protocol design. Moreover, the challenging physiology of the mouse heart, especially with respect to its small size and high heart rate, often limits the direct translation of imaging protocols already available from clinical studies. Finally, the growing knowledge on cardiac pathology continuously pushes the development of sophisticated mouse cardiac MRI protocols that allow more detailed measurements of a variety of physiologically relevant cardiac parameters. The overall goal of this thesis was therefore to design and investigate novel imaging strategies in the field of mouse cardiac MRI and their application in models of cardiac disease. Chapter 2 of this thesis contains an extensive overview of currently available protocols for mouse cardiac MRI and more specifically those related to contrast enhanced imaging of myocardial infarction. The remainder of the thesis contains the experimental chapters describing all details on our newly developed mouse cardiac MRI techniques. This chapter shortly summarizes the aims and results with respect to each of these techniques, categorized based on the parameter of interest for which each measurement was specifically designed. Diastolic function Measurement of murine diastolic function requires Cine imaging with an extremely high frame rate ¿ more than 60 frames within a cardiac cycle of 100-120 ms ¿ to be able to discriminate between the two separate filling phases of the heart. In chapter 3, it was shown that using a retrospectively triggered MRI sequence, reconstruction of 80 Cine images was feasible, corresponding to a temporal resolution of around 1.5 ms. This was achieved without using any form of data interpolation. With retrospective triggering, the MRI measurements are not synchronized with the ECG, thereby in theory sampling an infinite number of time points during the cardiac cycle. Correct assignment of each k-line to a specific cardiac frame could be done retrospectively by measuring an additional navigator signal prior to image acquisition, whose signal amplitude varies with cardiac as well as respiratory movements. Because in this case, filling of k-space for each cardiac frame is a stochastic process, simulations were performed to investigate the efficiency of the method with respect to signal averaging, which was found to be almost equal compared to regular prospective triggering. Diabetic cardiomyopathy has a high prevalence in type 2 diabetes patients and is characterized by diastolic dysfunction. With the current technique, we were indeed able to measure a subtle reduction is several diastolic function parameters, which are the E/A-ratio and the E-contribution to total left ventricular filling. Therefore, this technique is a promising tool in experimental studies of diabetic cardiomyopathy and for evaluation of emerging treatment strategies for diastolic dysfunction. Myocardial perfusion Chapter 4 describes the application of first-pass perfusion measurements in a mouse model of myocardial infarction to allow the assessment of the myocardial perfusion status. A first-pass perfusion measurement is performed by venous injection of an MRI contrast agent and monitoring its passage through the left ventricle and myocardial wall. From the signal intensity changes upon passage of the contrast agent, myocardial perfusion values can be determined. The application of this technique in mice requires ultra-fast MRI sequences that can sample the signal intensity-time curves with sufficient temporal resolution. Because this concerns imaging of non-periodic signal changes this is a much different problem compared to the diastolic function experiments described in chapter 3. We showed that using a saturation recovery MRI sequence with segmented k-space read-out in combination with parallel imaging acceleration techniques, a time-series of images could be acquired with a temporal resolution of 1 image for each 3 heart beats. The use of parallel imaging was crucial, since this requires less k-lines for image reconstruction compared to conventional imaging. Furthermore, the use of saturation pulses enhanced the contrast between contrast-enhanced and non-enhanced blood and myocardium. Using this technique, semi-quantitative perfusion values could be determined based on the upslope of the signal intensity-time curves. Experiments in mice with permanent occlusion of the LAD showed a significant decrease of perfusion values in the infarcted myocardium as compared to remote myocardium. In future experiments, this technique will be extended to provide quantitative perfusion values (in mg/l/min), requiring determination of the true arterial input function from a pre-bolus measurement with a smaller contrast agent bolus volume. T1 and T2 relaxation times Pathology is often accompanied by a change in the magnetic properties of the tissue, in particular the T1 and T2 relaxation times. This directly affects the signal intensity on the MR image. Diseased and healthy tissue can therefore be discriminated on MR images, which is one of the main applications of MRI in clinical diagnostics. However, there is much interest in quantitative assesment of T1 and T2 relaxation times, as this improves repeatibility of results in longitudinal studies and reproducibility between research groups. In this thesis, we aimed at developing protocols for both T1 and T2 mapping of the complete mouse heart for application in mouse models of myocardial infarction. Whole-heart coverage is important considering that a priori, the extent of the infarct is unknown. Currently available protocols for T1 mapping are relatvively time-consuming. In chapter 5, a 3D T1 mapping sequence is presented which allows myocardial T1 quantification of the mouse heart within 20 minutes. The retrospective triggering sequence used in chapter 3 proved also useful in this study, because it allows steady-state acqusition with very short repetition times, enabling whole heart coverage. T1 values were derived from measuring a variable flip angle data set and using available MRI signal models. Variable flip angle data showed excellent agreement in cardiac anatomy, allowing pixel-wise determination of T1. In healthy mice, no substantial differences in T1 were found for different heart regions in the 3D volume. Coefficents of repeatibility were determined from measurements at different days, which varied as function of the number of flip angles used in data analysis. In contrast to T1, T2 values could not be acquired using 3D acquisitons or retrospective triggering. Alternatively, chapter 6 describes a multi-slice T2 mapping protocol for the mouse heart based on a ECG-triggered T2 magnetization preparation module with variable TE. Because the preparation module consisted of many consecutive RF pulses, the effect of these pulses on T2 relxation had to be taken into account. Additionally, simulations were used to calculate the effect of T1 relaxation on T2 estimation, which was small as long as the repetition time was kept sufficiently long. Homogeneous T2 maps of healthy mouse heart were obtained, with no substantial differences between different heart regions or slices. In a ischemia/reperfusion model, elevated T2 values were found in the infarcted area, probably as result of edema formation. The extent of the infarction was also measured using late gadolinium enhanced imaging. The degree of correlation of T2 and LGE enhanced regions strongly depended on the signal intensity thresholds derived from remote tissue. Contrast agent accumulation Another application of quantitative T1 and T2¬ mapping is the assessment of the concentration of a contrast agent, which has been targeted to a specific disease site. This is especially valuable in molecular imaging applications where contrast agents report on the presence of specific disease markers related to various cardiac remodeling processes after myocardial infarction. Chapter 7 describes the application of the T1 mapping protocol from chapter 5 to quantify the accumulation of a Gd-based liposomal contrast agent in a model of myocardial infarction. Functional imaging and assessment of wall thickening values were used to determine which regions could be identified as being infarcted. Statistical analysis showed that before contrast agent administration, T¬1¬ values were already elevated in the infarcted regions as compared to remote myocardium, however, a more pronounced change in T1 values was found 24h post-contrast, with significantly lower T1 values in the infarcted areas. Pre-contrast T1 values in control mice were very similar to the study described in chapter 5, proving good reproducibility of T1 quantification using our methods. After the MRI measurement, the hearts were cut into slices, from which the Gd-content was determined in different sections of the heart using inductively coupled plasma mass spectrometry. T1 changes measured using in vivo MRI correlated well with ex vivo measurements of Gd concentration. These are promising results for quantification of contrast agent concentrations in contrast-enhanced MRI of mouse models of cardiac disease. More research has to be performed with regard to changes in contrast agent efficiency as a result of different cellular environments. Our results already indicate that the relaxivity values of liposomal contrast agents are significantly lower in vivo as compared to values obtained from measurements in phantom solutions. Conclusion This thesis has shown that mouse cardiac MRI is capable of assessing a large variety of parameters related to cardiac physiology in the in vivo mouse heart in a non-invasive way. This makes this technique an attractive platform for experimental studies on cardiac disease, as well as developing new treatment strategies

    Hymenophore configuration of the oak mazegill (Daedalea quercina)

    No full text
    The complex hymenophore configuration of the oak mazegill (Daedalea quercina, Polyporales) is rarely quantified, although quantifications are important analytical tools to assess form and growth. We quantified the hymenophore configuration of the oak mazegill by manual counting of tubes and tubular branches and ends. Complementary measurements were made with the software AngioTool. We found that the number of tubular branches and ends varied substantially between specimens, with a positive correlation with hymenophore area (5–51 cm2). We then measured complexity as tubular branches and ends per area, and complexity was not correlated with the size of the basidiocarps. Basidiocarps from two locations were compared (Hald ege, N = 11; Hvidding krat, N = 7), and the prevalence of branches and that of ends were greater in the Hvidding krat hymenophores (P < 0.001 and P = 0.029, respectively). Additionally, lacunarity, a measure of complexity (“gappiness”), gave a higher score for the Hald ege hymenophores (P = 0.002). Lacunarity analysis of multiple species of Polyporales showed that the oak mazegill hymenophore is comparatively complex. Concerning factors that affect hymenophore complexity of the oak mazegill, we observed that greater hymenophore complexity was associated with abrupt boundaries between growth zones on the pileus surface. Several years of monitoring documented that basidiocarps can remodel to gravitational changes and heal from damage. In conclusion, intra- and interspecies differences of hymenophore configuration can be quantified. In oak mazegill, hymenophore complexity is not dependent on size per se, although abrupt borders between growth zones are associated with increased complexity. Some of the variation between basidiocarps may reflect aspects of the ecology of the individual fungus

    Three-dimensional Diffusion Imaging with SPiral Encoded Navigators from Stimulated Echoes (3D-DISPENSE)

    No full text
    Purpose: To introduce a new method for motion-insensitive 3D multishot diffusion imaging using 3D spiral-encoded navigators from stimulated echoes (3D-DISPENSE). Methods: The 3D-DISPENSE sequence contains a 3D stack-of-spiral navigator generated between the diffusion preparation and the turbo spin-echo image acquisition from the twin pathway of a stimulated echo. Unlike normal navigator methods, 3D-DISPENSE separates the navigator acquisition from the imaging readout without compromising the image SNR. Phase information from the navigators was included in an iterative image reconstruction algorithm to correct for intershot phase incoherence caused by motion. Results: In a phantom experiment, 3D-DISPENSE correctly estimated deliberately introduced phase errors. In a moving phantom, motion-induced artifacts in the DWI were greatly mitigated by 3D-DISPENSE. The ADC after 3D-DISPENSE correction was identical to the reference. In a brain diffusion tensor experiment, phase-incoherence artifacts from breathing, cardiac, and subject motion were removed almost perfectly in all view angles, resulting in distortion-free DWI and color-coded fractional anisotropy maps with 1.5-mm isotropic resolution and nearly full brain coverage. Conclusion: Three-dimensional DISPENSE corrects motion-induced phase-incoherence artifacts in 3D multishot diffusion imaging and produces high-quality 3D DWI and DTI

    Compressed sensing MRI with variable density averaging (CS-VDA) outperforms full sampling at low SNR

    No full text
    We investigated whether a combination of k-space undersampling and variable density averaging enhances image quality for low-SNR MRI acquisitions. We implemented 3D Cartesian k-space prospective undersampling with a variable number of averages for each k-line. The performance of this compressed sensing with variable-density averaging (CS-VDA) method was evaluated in retrospective analysis of fully sampled phantom MRI measurements, as well as for prospectively accelerated in vivo 3D brain and knee MRI scans. Both phantom and in vivo results showed that acquisitions using the CS-VDA approach resulted in better image quality as compared to full sampling of k-space in the same scan time. Specifically, CS-VDA with a higher number of averages in the center of k-space resulted in the best image quality, apparent from increased anatomical detail with preserved soft-tissue contrast. This novel approach will facilitate improved image quality of inherently low SNR data, such as those with high-resolution or specific contrast-weightings with low SNR efficiency

    Laterality defect of the heart in non-teleost fish

    No full text
    Dextrocardia is a rare congenital malformation in humans in which most of the heart mass is positioned in the right hemithorax rather than on the left. The heart itself may be normal and dextrocardia is sometimes diagnosed during non-related explorations. A few reports have documented atypical positions of the cardiac chambers in farmed teleost fish. Here, we report the casual finding of a left-right mirrored heart in an 85 cm long wild-caught spiny dogfish (Squalus acanthias) with several organ malformations. Macroscopic observations showed an outflow tract originating from the left side of the ventricular mass, rather than from the right. Internal inspection revealed the expected structures and a looped cavity. The inner curvature of the loop comprised a large trabeculation, the bulboventricular fold, as expected. The junction between the sinus venosus and the atrium appeared normal, only mirrored. MRI data acquired at 0.7 mm isotropic resolution and subsequent 3D-modeling revealed the atrioventricular canal was to the right of the bulboventricular fold, rather than on the left. Spurred by the finding of dextrocardia in the shark, we revisit our previously published material on farmed Adriatic sturgeon (Acipenser naccarii), a non-teleost bony fish. We found several alevins with inverted (left-loop) hearts, amounting to an approximate incidence of 1%-2%. Additionally, an adult sturgeon measuring 90 cm in length showed abnormal topology of the cardiac chambers, but normal position of the abdominal organs. In conclusion, left-right mirrored hearts, a setting that resembles human dextrocardia, can occur in both farmed and wild non-teleost fish.ACKNOWLEDGMENTS. The authors wish to thank A. Domezain, from the Sierra Nevada Fishery at Riofrío, Granada, Spain, for generous access to the sturgeon material. Jaco Hagoort's help in generating the 3D model is much appreciate

    Three-dimensional T1 mapping of the mouse heart using variable flip angle steady-state MR imaging

    No full text
    Cardiac MR T(1) mapping is a promising quantitative imaging tool for the diagnosis and evaluation of cardiomyopathy. Here, we present a new preclinical cardiac MRI method enabling three-dimensional T(1) mapping of the mouse heart. The method is based on a variable flip angle analysis of steady-state MR imaging data. A retrospectively triggered three-dimensional FLASH (fast low-angle shot) sequence (3D IntraGate) enables a constant repetition time and maintains steady-state conditions. 3D T(1) mapping of the complete mouse heart could be achieved in 20 min. High-quality, bright-blood T(1) maps were obtained with homogeneous T(1) values (1764 ± 172 ms) throughout the myocardium. The repeatability coefficient of R(1) (1/T(1) ) in a specific region of the mouse heart was between 0.14 and 0.20 s(-1) , depending on the number of flip angles. The feasibility for detecting regional differences in ΔR(1) was shown with pre- and post-contrast T(1) mapping in mice with surgically induced myocardial infarction, for which ΔR(1) values up to 0.83 s(-1) were found in the infarct zone. The sequence was also investigated in black-blood mode, which, interestingly, showed a strong decrease in the apparent mean T(1) of healthy myocardium (905 ± 110 ms). This study shows that 3D T(1) mapping in the mouse heart is feasible and can be used to monitor regional changes in myocardial T(1), particularly in relation to pathology and in contrast-enhanced experiments to estimate local concentrations of (targeted) contrast agen

    Vessel wall characterization using quantitative MRI: what's in a number?

    No full text
    The past decade has witnessed the rapid development of new MRI technology for vessel wall imaging. Today, with advances in MRI hardware and pulse sequences, quantitative MRI of the vessel wall represents a real alternative to conventional qualitative imaging, which is hindered by significant intra- and inter-observer variability. Quantitative MRI can measure several important morphological and functional characteristics of the vessel wall. This review provides a detailed introduction to novel quantitative MRI methods for measuring vessel wall dimensions, plaque composition and permeability, endothelial shear stress and wall stiffness. Together, these methods show the versatility of non-invasive quantitative MRI for probing vascular disease at several stages. These quantitative MRI biomarkers can play an important role in the context of both treatment response monitoring and risk prediction. Given the rapid developments in scan acceleration techniques and novel image reconstruction, we foresee the possibility of integrating the acquisition of multiple quantitative vessel wall parameters within a single scan sessio
    corecore