7 research outputs found

    Three-dimensional evaluation of bracket placement accuracy and excess bonding adhesive depending on indirect bonding technique and bracket geometry: an in-vitro study

    No full text
    Abstract Background This study aimed at comparing bracket placement and excess bonding adhesive depending on different indirect bonding (IDB) techniques and bracket geometries. Methods Four hundred eighty brackets without hook (WOH) and 360 with hook (WH) were placed on 60 plaster models. Three IDB techniques were tested: polyvinyl-siloxane vacuum-form (PVS-VF), polyvinyl-siloxane putty (PVS-putty), and translucence double-polyvinyl-siloxane (double-PVS). PVS-VF and PVS-putty were combined with chemically, and double-PVS was combined with light cured bonding adhesive. Virtual images of models before and after bracket transfer were generated, and computerized images were compared. Linear, angular deviations, and excess bonding adhesive were measured. Results Linear differences between the three groups were obtained for PVS-VF (WH: 1.08, SD 0.50 mm; WOH: 0.86, SD 0.25 mm), PVS-putty (WH: 0.73, SD 0.51 mm; WOH: 0.58, SD 0.28 mm), and double-PVS (WH: 0.65, SD 0.45 mm; WOH: 0.59, SD 0.33 mm) (P &lt; 0.001). Hooks affected bracket placement accuracy in PVS-VF (P &lt; 0.001) and PVS-putty (P = 0.029). Angular differences were observed for brackets WOH between the PVS-VF (0.64, SD 0.48°) and double-PVS group (0.92, SD 0.76°) (P &lt; 0.001) and within double-PVS group (WH: 0.66, SD 0.51° vs. WOH: 0.92, SD 0.76°, P &lt; 0.001). Highest amount of excess adhesive was obtained for PVS-putty group (WH: 6.54, SD 5.31 mm 2). Conclusions The double-PVS group revealed promising results with respect to transfer accuracy, whereas the PVS-VF group provided least excess bonding adhesive. Basically, hooks lead to lower precision and higher excess bonding adhesive. PVS trays for IDB generate high bracket placement accuracy. PVS-putty is the easiest to handle with and also the cheapest, but leads to large excess bonding adhesive, especially in combination with hooked brackets or tubes. </jats:sec

    Three-dimensional evaluation of bracket placement accuracy and excess bonding adhesive depending on indirect bonding technique and bracket geometry: an in-vitro study

    No full text
    Background!#!This study aimed at comparing bracket placement and excess bonding adhesive depending on different indirect bonding (IDB) techniques and bracket geometries.!##!Methods!#!Four hundred eighty brackets without hook (WOH) and 360 with hook (WH) were placed on 60 plaster models. Three IDB techniques were tested: polyvinyl-siloxane vacuum-form (PVS-VF), polyvinyl-siloxane putty (PVS-putty), and translucence double-polyvinyl-siloxane (double-PVS). PVS-VF and PVS-putty were combined with chemically, and double-PVS was combined with light cured bonding adhesive. Virtual images of models before and after bracket transfer were generated, and computerized images were compared. Linear, angular deviations, and excess bonding adhesive were measured.!##!Results!#!Linear differences between the three groups were obtained for PVS-VF (WH: 1.08, SD 0.50 mm; WOH: 0.86, SD 0.25 mm), PVS-putty (WH: 0.73, SD 0.51 mm; WOH: 0.58, SD 0.28 mm), and double-PVS (WH: 0.65, SD 0.45 mm; WOH: 0.59, SD 0.33 mm) (P &amp;lt; 0.001). Hooks affected bracket placement accuracy in PVS-VF (P &amp;lt; 0.001) and PVS-putty (P = 0.029). Angular differences were observed for brackets WOH between the PVS-VF (0.64, SD 0.48°) and double-PVS group (0.92, SD 0.76°) (P &amp;lt; 0.001) and within double-PVS group (WH: 0.66, SD 0.51° vs. WOH: 0.92, SD 0.76°, P &amp;lt; 0.001). Highest amount of excess adhesive was obtained for PVS-putty group (WH: 6.54, SD 5.31 mm !##!Conclusions!#!The double-PVS group revealed promising results with respect to transfer accuracy, whereas the PVS-VF group provided least excess bonding adhesive. Basically, hooks lead to lower precision and higher excess bonding adhesive. PVS trays for IDB generate high bracket placement accuracy. PVS-putty is the easiest to handle with and also the cheapest, but leads to large excess bonding adhesive, especially in combination with hooked brackets or tubes

    Long-Living Intermediates during a Lamellar to a Diamond-Cubic Lipid Phase Transition: A Small-Angle X-Ray Scattering Investigation

    No full text
    To generate nanostructured vehicles with tunable internal organization, the structural phase behavior of a self-assembled amphiphilic mixture involving poly(ethylene glycol) monooleate (MO-PEG) and glycerol monooleate (MO) is studied in excess aqueous medium by time-resolved small-angle X-ray scattering (SAXS) in the temperature range from 1 to 68 degrees C. The SAXS data indicate miscibility of the two components in lamellar and nonlamellar soft-matter nanostructures. The functionalization of the MO assemblies by a MO-PEG amphiphile, which has a flexible large hydrophilic moiety, appears to hinder the epitaxial growth of a double diamond (D) cubic lattice from the lamellar (L) bilayer structure during the thermal phase transition. The incorporated MO-PEG additive is found to facilitate the formation of structural intermediates. They exhibit greater characteristic spacings and large diffusive scattering in broad temperature and time intervals. Their features are compared with those of swollen long-living intermediates in MO/octylglucoside assemblies. A conclusion can be drawn that long-living intermediate states can be equilibrium stabilized in two- or multicomponent amphiphilic systems. Their role as cubic phase precursors is to smooth the structural distortions arising from curvature mismatch between flat and curved regions. The considered MO-PEG functionalized assemblies may be useful for preparation of sterically stabilized liquid-crystalline nanovehicles for confinement of therapeutic biomolecules