712 research outputs found

    The role of cardiac troponin T quantity and function in cardiac development and dilated cardiomyopathy

    Get PDF
    Background: Hypertrophic (HCM) and dilated (DCM) cardiomyopathies results from sarcomeric protein mutations, including cardiac troponin T (cTnT, TNNT2). We determined whether TNNT2 mutations cause cardiomyopathies by altering cTnT function or quantity; whether the severity of DCM is related to the ratio of mutant to wildtype cTnT; whether Ca2+ desensitization occurs in DCM; and whether absence of cTnT impairs early embryonic cardiogenesis. Methods and Findings: We ablated Tnnt2 to produce heterozygous Tnnt2+/ mice, and crossbreeding produced homozygous null Tnnt2-/-embryos. We also generated transgenic mice overexpressing wildtype (TGWT) or DCM mutant (TGK210Δ) Tnnt2. Crossbreeding produced mice lacking one allele of Tnnt2, but carrying wildtype (Tnnt2+/-/TGWT) or mutant (Tnnt2+/-/TGK210Δ) transgenes. Tnnt2+/-mice relative to wildtype had significantly reduced transcript (0.82 ± 0.06 [SD] vs. 1.00 ± 0.12 arbitrary units; p = 0.025), but not protein (1.01 ± 0.20 vs. 1.00 ± 0.13 arbitrary units; p = 0.44). Tnnt2+/-mice had normal hearts (histology, mass, left ventricular end diastolic diameter [LVEDD], fractional shortening [FS]). Moreover, whereas Tnnt2+/-/ TGK210Δ mice had severe DCM, TGK210Δ mice had only mild DCM (FS 18 ± 4 vs. 29 ± 7%; p < 0.01). The difference in severity of DCM may be attributable to a greater ratio of mutant to wildtype Tnnt2 transcript in Tnnt2+/-/TGK210Δ relative to TGK210Δ mice (2.42±0.08, p = 0.03). Tnnt2+/-/TGK210Δ muscle showed Ca2+ desensitization (pCa50 = 5.34 ± 0.08 vs. 5.58 ± 0.03 at sarcomere length 1.9 μm. p<0.01), but no difference in maximum force generation. Day 9.5 Tnnt2-/-embryos had normally looped hearts, but thin ventricular walls, large pericardial effusions, noncontractile hearts, and severely disorganized sarcomeres. Conclusions: Absence of one Tnnt2 allele leads to a mild deficit in transcript but not protein, leading to a normal cardiac phenotype. DCM results from abnormal function of a mutant protein, which is associated with myocyte Ca2+ desensitization. The severity of DCM depends on the ratio of mutant to wildtype Tnnt2 transcript. cTnT is essential for sarcomere formation, but normal embryonic heart looping occurs without contractile activity. © 2008 Ahmad et al

    Factors influencing the use of public dental services: An application of the Theory of Planned Behaviour

    Get PDF
    Background There is limited evidence of the influence of psychosocial factors and health beliefs on public dental patient's patterns of service use in Australia. The research aims were to examine associations between dental attitudes and beliefs of public dental service users and dental visiting intention and behaviour using the Theory of Planned Behaviour. Methods 517 randomly selected adult public dental patients completed a questionnaire assessing dental attitudes and beliefs which was matched with electronic records for past and future dental service use. A questionnaire measured intentions, attitudes, subjective norms and perceptions of behavioural control and self-efficacy in relation to visiting public dentists. A measure of dental attendance at public dental clinics was obtained retrospectively (over 3 1/2 years) and prospectively (over a one year period following the return of the questionnaire) by accessing electronic patient clinical records. Results Participants had positive attitudes, subjective norms and self-efficacy beliefs towards dental visiting but perceived a lack of control over visiting the dentist. Attitudes, subjective norms, self-efficacy and perceived control were significant predictors of intention (P &lt; 0.05). Intentions, self-efficacy and past dental attendance were significant predictors of actual dental attendance (P &lt; 0.05). Conclusion Public dental patients held favourable attitudes and beliefs but perceived a lack of control towards dental visiting. Reducing structural barriers may therefore improve access to public dental services.Liana Luzzi and A John Spence

    Triage for coronary artery bypass graft surgery in Canada: Do patients agree on who should come first?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The extent to which clinical and non-clinical factors impact on the waiting-list prioritization preferences of patients in the queue is unknown. Using a series of hypothetical scenarios, the objective of this study was to examine the extent to which clinical and non-clinical factors impacted on how patients would prioritize others relative to themselves in the coronary artery bypass surgical queue.</p> <p>Methods</p> <p>Ninety-one consecutive eligible patients awaiting coronary artery bypass grafting surgery at Sunnybrook Health Sciences Centre (median waiting-time duration prior to survey of 8 weeks) were given a self-administered survey consisting of nine scenarios in which clinical and non-clinical characteristic profiles of hypothetical patients (also awaiting coronary artery bypass surgery) were varied. For each scenario, patients were asked where in the queue such hypothetical patients should be placed relative to themselves.</p> <p>Results</p> <p>The eligible response rate was 65% (59/91). Most respondents put themselves marginally ahead of a hypothetical patient with identical clinical and non-clinical characteristics as themselves. There was a strong tendency for respondents to place patients of higher clinical acuity ahead of themselves in the queue (P < 0.0001). Social independence among young individuals was a positively valued attribute (P < 0.0001), but neither age per se nor financial status, directly impacted on patients waiting-list priority preferences.</p> <p>Conclusion</p> <p>While patient perceptions generally reaffirmed a bypass surgical triage process based on principals of equity and clinical acuity, the valuation of social independence may justify further debate with regard to the inclusion of non-clinical factors in waiting-list prioritization management systems in Canada, as elsewhere.</p

    The effects of publishing emergency department wait time on patient utilization patterns in a community with two emergency department sites: a retrospective, quasi-experiment design

    Get PDF
    BACKGROUND: Providing emergency department (ED) wait time information to the public has been suggested as a mechanism to reduce lengthy ED wait times (by enabling patients to select the ED site with shorter wait time), but the effects of such a program have not been evaluated. We evaluated the effects of such a program in a community with two ED sites. METHODS: Descriptive statistics for wait times of the two sites before and after the publication of wait time information were used to evaluate the effects of the publication of wait time information on wait times. Multivariate logistical regression was used to test whether or not individual patients used published wait time to decide which site to visit. RESULTS: We found that the rates of wait times exceeding 4 h, and the 95th percentile of wait times in the two sites decreased after the publication of wait time information, even though the average wait times experienced a slight increase. We also found that after controlling for other factors, the site with shorter wait time had a higher likelihood of being selected after the publication of wait time information, but there was no such relationship before the publication. CONCLUSIONS: These findings were consistent with the hypothesis that the publication of wait time information leads to patients selecting the site with shorter wait time. While publishing ED wait time information did not improve average wait time, it reduced the rates of lengthy wait times

    How Do Physical Therapists Treat People with Knee Osteoarthritis, and What Drives Their Clinical Decisions? A Population-Based Cross-Sectional Survey.

    Get PDF
    Purpose: It is unclear how physical therapists in Florida currently treat people with knee osteoarthritis and whether current best evidence is used in clinical decision making. Methods: We conducted a survey of physical therapists in Florida. We assessed the perceived effectiveness and actual use of physical therapy (PT) interventions and quantified the association between the actual use of interventions and different characteristics of physical therapists. Results: A total of 413 physical therapists completed the survey. Most respondents perceived therapeutic exercise (94%) and education (93%) as being effective or very effective. Interventions least perceived as effective or very effective were electrotherapy (28%), wedged insole (20%), and ultrasound (19%). Physical therapists who followed the principles of evidence-based practice were more likely to use therapeutic exercise (OR 3.89; 95% CI: 1.21, 12.54) and education (OR 3.63; 95% CI: 1.40, 9.43) and less likely to use ultrasound (OR 0.32; 95% CI: 0.16, 0.63) and electrotherapy (OR 0.32; 95% CI: 0.17, 0.58). Results also indicated that older physical therapists were more likely to use ultrasound (OR 3.57; 95% CI: 1.60, 7.96), electrotherapy (OR 2.53; 95% CI: 1.17, 5.47), kinesiology tape (OR 3.82; 95% CI: 1.59, 9.18), and ice (OR 1.95; 95% CI: 1.02, 3.73). Conclusions: In line with clinical guidelines, most physical therapists use therapeutic exercise and education to treat people with knee osteoarthritis. However, interventions that lack scientific support, such as electrotherapy and ultrasound, are still used. A modifiable therapist characteristic, adherence to evidence-based practice, is positively associated with the use of interventions supported by scientific evidence

    Metastatic breast carcinoma mimicking a sebaceous gland neoplasm: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Breast cancer is common in women and its metastases involve the skin in approximately one quarter of patients. Accordingly, metastatic breast cancer shown to be cutaneous through histology must be distinguished from a wide variety of other neoplasms as well as the diverse morphologic variants of breast cancer itself.</p> <p>Case presentation</p> <p>We report the case of a 61-year-old Caucasian woman with cutaneous metastases of a bilateral ductal breast carcinoma that in histopathological examination mimicked an adnexal neoplasm with sebaceous differentiation.</p> <p>Conclusion</p> <p>Against the background of metastatic breast carcinoma, dermatopathological considerations of sebaceous differentiation of skin lesions are presented and discussed focusing on the rare differential diagnosis of sebaceous carcinoma of the breast.</p

    Movement and habitat use of the snapping turtle in an urban landscape

    Get PDF
    In order to effectively manage urban habitats, it is important to incorporate the spatial ecology and habitat use of the species utilizing them. Our previous studies have shown that the distribution of upland habitats surrounding a highly urbanized wetland habitat, the Central Canal (Indianapolis, IN, USA) influences the distribution of map turtles (Graptemys geographica) and red-eared sliders (Trachemys scripta) during both the active season and hibernation. In this study we detail the movements and habitat use of another prominent member of the Central Canal turtle assemblage, the common snapping turtle, Chelydra serpentina. We find the same major upland habitat associations for C. serpentina as for G. geographica and T. scripta, despite major differences in their activity (e.g., C. serpentina do not regularly engage in aerial basking). These results reinforce the importance of recognizing the connection between aquatic and surrounding terrestrial habitats, especially in urban ecosystems

    Suicide among adults aged 30–49: A psychological autopsy study in Hong Kong

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A surge in suicide rates in middle age people in Hong Kong and many Asian countries was recently observed. However, there is a paucity of suicide research on this subgroup of people in Asia.</p> <p>Methods</p> <p>The next-of-kin of 85 suicide cases and 85 community subjects aged 30–49 years were interviewed by a psychological autopsy approach. Information was triangulated by interview notes, coroner's court files, and police investigation reports.</p> <p>Results</p> <p>A multiple logistic regression analysis identified the following risk factors for suicide among the middle age people in Hong Kong: the presence of at least one psychiatric disorder (OR = 37.5, 95% CI 11.5–121.9, p < 0.001), indebtedness (OR = 9.4, 95% CI 2.2–40.8, p < 0.01), unemployment (OR = 4.8, 95% CI 1.3–17.5, p < 0.05), never married (OR = 4.2, 95% CI 1.1–16.3, p < 0.05), and lived alone (OR = 3.9, 95% CI 1.2–13.4, p < 0.05).</p> <p>Conclusion</p> <p>The data show that socio-economical factors had a strong impact on suicide in the target group. Further research is needed to explore any positive qualities that protect the middle-aged from suicide. The prevention of suicide in the middle-aged requires multiple strategies.</p

    Biomechanical testing of fixed and adjustable femoral cortical suspension devices for ACL reconstruction under high loads and extended cyclic loading

    Get PDF
    Purpose: To compare loop elongation after 5000 cycles, loop-elongation at failure, and load at failure of the fixed-loop G-Lok device and three adjustable-loop devices (UltraButton, RigidLoop Adjustable and ProCinch RT), during testing over extended cycles under high loading. Methods: Five devices of each type were tested on a custom-built rig fixed to an Instron machine. The testing protocol had four stages: preloading, cyclic preconditioning, incremental cyclic loading and pull-to-failure. Outcome measures were loop elongation after 5000 cycles, loop-elongation at failure, and load at failure. Results: The loop elongation after 5000 cycles for G-Lok was 1.46 ± 0.25 mm, which was comparable to that of RigidLoop (1.51 ± 0.16 mm, p = 1.000) and ProCinch (1.60 ± 0.09 mm, p = 1.000). In comparison, the loop elongation for UltraButton was 2.66 ± 0.28 mm, which was significantly larger than all other devices (p = 0.048). The failure load for all devices ranged between 1455 and 2178 N. G-Lok was significantly stronger than all adjustable-loop devices (p = 0.048). The elongation at failure was largest for UltraButton (4.20 ± 0.33 mm), which was significantly greater than G-Lok (3.17 ± 0.33 mm, p = 0.048), RigidLoop (2.88 ± 0.20 mm, p = 0.048) and ProCinch (2.78 ± 0.08 mm, p = 0.048). There was no significant difference in elongation at failure for the rest of the devices. Conclusions: Our study has shown that the G-Lok fixed-loop device and the three adjustable-loop devices (UltraButton, RigidLoop Adjustable and ProCinch RT) all elongated less than 3 mm during testing over an extended number of cycles at high loads, nonetheless, the fixed loop device performed best in terms of least elongation and highest load at failure.This article is freely available via Open Access. Click on the Publisher URL to access it via the publisher's site.published version, accepted versio
    • …
    corecore