1,332 research outputs found

    Gravitational wave scintillation by a stellar cluster

    Get PDF
    The diffraction effects on gravitational waves propagating through a stellar cluster are analyzed in the relevant approximation of Fresnel diffraction limit. We find that a gravitational wave scintillation effect - similar to the radio source scintillation effect - comes out naturally, implying that the gravitational wave intensity changes in a characteristic way as the observer moves.Comment: 9 pages, in press in IJMP

    A new device hypothesis for water extraction from air and basic air condition system in developing countries

    Get PDF
    This work proposes a new device for air treatment with dehumidification and water recovery/storage, with possible mitigation of indoor environmental conditions. The system is based on Peltier cells coupled with a horizontal earth‐to‐air heat exchanger, it is proposed as an easy‐to-implement alternative to the heat pumps and air handling units currently used on the market, in terms of cost, ease of installation, and maintenance. The process provides the water collection from the cooling of warm‐humid air through a process that leads to condensation and water vapor separation. The airflow generated by a fan splits into two dual flows that lap the two surfaces of the Peltier cells, one flow laps the cold surfaces undergoing sensible, latent cooling with dehumidification; the other flow laps the hot surfaces and heats up. The airflow undergoes thermal pre‐treatment through the underground horizontal geothermal pipe that precedes the Peltier cells. In the water storage tank, which also works as a mixing chamber, the two air streams are mixed to regulate the outlet temperature. The system can be stand‐alone if equipped with a photovoltaic panel and a micro wind turbine, able to be used in places where electricity is absent. The system, with different configurations, is modeled in the African city Kigali, in Rwanda

    Experimental analysis of the rising damp by the comparison between different geometrical configurations: mono and multi-blocks of carparo and pietra leccese

    Get PDF
    The rising damp is the principal cause of the deterioration of the masonry in the existing constructions. Since carparo and pietra leccese are the most used materials in southern Italy, this study aims to underline the trend of the rising damp for the two building materials considering mono and multi- block configurations. All analyzes were developed with and without the influence of the Domodry® system

    Energy Independence of a Small Office Community Powered by Photovoltaic-Wind Hybrid Systems in Widely Different Climates

    Get PDF
    Hybrid renewable energy systems are an optimal solution for small energy communities’ energy supply. One of the critical issues is the strong correlation of these systems with outdoor climatic conditions. The goal is to make local communities increasingly energy independent. To this end, an in-depth analysis of the behaviour of hybrid photovoltaic (PV)–wind systems powering small office communities in 48 locations around the world characterized by widely varying climates was conducted. System sizes, assumed to be stand-alone or grid-connected, were varied, for a total of 343 system power configurations. Highest satisfied load fraction (SLF) values are obtained with a significant predominance of PV over wind; the trend is more pronounced in dry and continental climates (zones B and D according to the Köppen climate classification). The utilization factor (UF) values of 1 are rarely reached and never in the wind-only or PV-only configurations. In all climates, the grid energy interaction factor (GEIF) values of zero are never reached but come very close. The benefit-cost ratio (BCR) of grid-connected systems is significantly higher than stand-alone systems

    Definition of a Protocol for the Experimental Monitoring of Rising Damp in Three Different Masonry Models with Tuff, Carparo, and Lecce Stone

    Get PDF
    This work presents a new protocol for monitoring rising damp, which is applied to three masonry models made of tuff, carparo, and Lecce stone. First, the physical characteristics of each stone were derived in the laboratory, which included porosity, imbibition, drying index, permeability, capillarity, and sorptivity. In this case, the protocol provided three columns, one for each material, consisting of five blocks. A layer of cotton tissue was interposed between columned blocks to simulate the hygroscopic behavior of a mortar, allowing a quick disassembly and reassembly of the multiblock columns for a quick weighing. The bottoms of the columns were immersed in water to a level of about three centimeters, providing a constant replenishment for the phenomena of evaporation and rising in the stone. The maximum height achieved by the rising damp depends on the characteristics of the building materials, i.e., the amount and size of pores, pore connectivity, etc. Since these materials have different physical characteristics, the objective was to quantify the rising moisture level of the three materials tested, block by block, in a controlled indoor microclimate environment. The three columns were periodically weighed, the quantity of collected water was evaluated, and a thermographic survey was performed. The results show that at the end of the test, the highest level of rising damp is reached by tuff with a height of 43 cm, followed by Lecce stone and carparo with a height of 40 cm and 21 cm, respectively. The innovation of this study is the proposal of a new flexible and easy‐to‐apply method for monitoring this phenomenon. It gives clear and numerically comparable results. Moreover, it is applicable to any type of stone, allowing the user to evaluate both the existing state and different design solutions

    Thermal Modeling of a Historical Building Wall: Using Long-Term Monitoring Data to Understand the Reliability and the Robustness of Numerical Simulations

    Get PDF
    Thermal modeling of building components plays a crucial role in designing energy efficiency measures, assessing living comfort, and preventing building damages. The accuracy of the modeling process strongly depends on the reliability of the physical models and the correct selection of input parameters, especially for historic buildings where uncertainties on wall composition and material properties are higher. This work evaluates the reliability of building thermal modeling and identifies the input parameters that most affect the simulation results. A monitoring system is applied to a historic building wall to measure the temperature profile. The long-term dataset is compared with the result of a simulation model. A sensitivity analysis is applied for the determination of the influential input parameters. A two-step optimization is performed to calibrate the numerical model: the first optimization step is based on an optimized selection of the database materials, while the second optimization step uses a particle swarm algorithm. The results indicate that the output of the simulation model is largely influenced by the coefficients describing the coupling with the boundary conditions and by the thermal conductivities of the materials. Very good results are obtained already after the first optimization step ((Formula presented.) while the second optimization step improves further the agreement ((Formula presented.). The parameter values reported in the datasheets do not match those found through optimization. Even with extensive optimization using an algorithm, starting with monitoring data is insufficient to identify material parameter values

    Eco-Sustainable Energy Production in Healthcare: Trends and Challenges in Renewable Energy Systems

    Get PDF
    The shift from fossil fuels to renewable energy systems represents a pivotal step toward the realization of a sustainable society. This study aims to analyze representative scientific literature on eco-sustainable energy production in the healthcare sector, particularly in hospitals. Given hospitals’ substantial electricity consumption, the adoption of renewable energy offers a reliable, low-CO2 emission solution. The COVID-19 pandemic has underscored the urgency for energy-efficient and environmentally-responsible approaches. This brief review analyzes the development of experimental, simulation, and optimization projects for sustainable energy production in healthcare facilities. The analysis reveals trends and challenges in renewable energy systems, offering valuable insights into the potential of eco-sustainable solutions in the healthcare sector. The findings indicate that hydrogen storage systems are consistently coupled with photovoltaic panels or solar collectors, but only 14% of the analyzed studies explore this potential within hospital settings. Hybrid renewable energy systems (HRES) could be used to meet the energy demands of healthcare centers and hospitals. However, the integration of HRES in hospitals and medical buildings is understudied
    corecore