230 research outputs found

    A Large-Diameter Hollow-Shaft Cryogenic Motor Based on a Superconducting Magnetic Bearing for Millimeter-Wave Polarimetry

    Full text link
    In this paper we present the design and measured performance of a novel cryogenic motor based on a superconducting magnetic bearing (SMB). The motor is tailored for use in millimeter-wave half-wave plate (HWP) polarimeters, where a HWP is rapidly rotated in front of a polarization analyzer or polarization-sensitive detector. This polarimetry technique is commonly used in cosmic microwave background (CMB) polarization studies. The SMB we use is composed of fourteen yttrium barium copper oxide (YBCO) disks and a contiguous neodymium iron boron (NdFeB) ring magnet. The motor is a hollow-shaft motor because the HWP is ultimately installed in the rotor. The motor presented here has a 100 mm diameter rotor aperture. However, the design can be scaled up to rotor aperture diameters of approximately 500 mm. Our motor system is composed of four primary subsystems: (i) the rotor assembly, which includes the NdFeB ring magnet, (ii) the stator assembly, which includes the YBCO disks, (iii) an incremental encoder, and (iv) the drive electronics. While the YBCO is cooling through its superconducting transition, the rotor is held above the stator by a novel hold and release mechanism (HRM). The encoder subsystem consists of a custom-built encoder disk read out by two fiber optic readout sensors. For the demonstration described in this paper, we ran the motor at 50 K and tested rotation frequencies up to approximately 10 Hz. The feedback system was able to stabilize the the rotation speed to approximately 0.4%, and the measured rotor orientation angle uncertainty is less than 0.15 deg. Lower temperature operation will require additional development activities, which we will discuss

    Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization

    Get PDF
    We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 \:GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 \:mK. The measured average resonator QQs are 1.7×104\times{10^4}, 7.0×104\times{10^4}, 1.0×104\times{10^4}, and 1.0×104\times{10^4} for the 150, 250, 350, and 460 \:GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 \:rad/pW, 1.5 \:rad/pW, 2.1 \:rad/pW, and 2.1 \:rad/pW; the electrical noise equivalent powers are 45 aW/Hz\:\rm{aW/\sqrt{Hz}}, 160 aW/Hz\:\rm{aW/\sqrt{Hz}}, 80 aW/Hz\:\rm{aW/\sqrt{Hz}}, and 140 aW/Hz\:\rm{aW/\sqrt{Hz}}, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NETRJ_{\rm RJ}s are 200 μKs200\:\mu\rm{K\sqrt{s}}, 240 μKs240\:\mu\rm{K\sqrt{s}}, 240 μKs240\:\mu\rm{K\sqrt{s}}, and  340μKs\:340\mu\rm{K\sqrt{s}}, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.Comment: Published on JCA

    The long duration cryogenic system of the OLIMPO balloon--borne experiment: design and in--flight performance

    Get PDF
    We describe the design and in--flight performance of the cryostat and the self-contained 3^{3}He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies. The 3^{3}He refrigerator provides the 0.3 K operation temperature for the four arrays of kinetic inductance detectors working in 4 bands centered at 150, 250, 350 and 460 GHz. The cryostat provides the 1.65 K base temperature for the 3^{3}He refrigerator, and cools down the reimaging optics and the filters chain at about 2 K. The integrated system was designed for a hold time of about 15 days, to achieve the sensitivity required by the planned OLIMPO observations, and successfully operated during the first long-duration stratospheric flight of OLIMPO in July 2018. The cryostat features two tanks, one for liquid nitrogen and the other one for liquid helium. The long hold time has been achieved by means of custom stiff G10 fiberglass tubes support, which ensures low thermal conductivity and remarkable structural stiffness; multi--layer superinsulation, and a vapour cooled shield, all reducing the heat load on the liquid helium tank. The system was tested in the lab, with more than 15 days of unmanned operations, and then in the long duration balloon flight in the stratosphere. In both cases, the detector temperature was below 300 mK, with thermal stability better than ±\pm 0.5 mK. The system also operated successfully in the long duration stratospheric balloon flight

    Measuring CMB spectral distortions from Antarctica with COSMO: blackbody calibrator design and performance forecast

    Get PDF
    COSMO is a ground-based instrument to measure the spectral distortions (SD) of the Cosmic Microwave Background (CMB). In this paper, we present preliminary results of electromagnetic simulations of its reference blackbody calibrator. HFSS simulations provide a calibrator reflection coefficient of R∼ 10 - 6, corresponding to an emissivity ϵ= 1 - R= 0.999999. We also provide a forecast for the instrument performance by using an ILC-based simulation. We show that COSMO can extract the isotropic Comptonization parameter (modeled as | y| = 1.77 · 10 - 6) as | y| = (1.79 ± 0.19) · 10 - 6, in the presence of the main Galactic foreground (thermal dust) and of CMB anisotropies, and assuming perfect atmospheric emission removal

    QUBIC: The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background

    Get PDF
    In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.Fil: Mennella, Aniello. University of Milan; ItaliaFil: Ade, P. A. R.. Cardiff University; Reino UnidoFil: Aumont, J.. Institut d'Astrophysique Spatiale; FranciaFil: Banfie, S.. Istituto Nazionale Di Fisica Nucleare; ItaliaFil: Battaglia, P.. Università degli Studi di Trieste; ItaliaFil: Battistelli, E. S.. Università degli Studi di Roma "La Sapienza"; ItaliaFil: Baùe, F.. Istituto Nazionale Di Fisica Nucleare; ItaliaFil: Buzi, D.. Università degli Studi di Roma "La Sapienza"; ItaliaFil: Columbro, F.. Università degli Studi di Roma "La Sapienza"; ItaliaFil: Bélie, B.. Institute of Fundamental Electronics; FranciaFil: Bennett, D.. Maynooth University; IrlandaFil: Bergé, L.. Centre de Sciences Nucléaires et de Sciences de la Matière; FranciaFil: Bernard, J. Ph.. Institut de Recherche en Astrophysique et Planétologie; FranciaFil: Bersanelli, M.. University of Milan; ItaliaFil: Bigot Sazy, M. A.. APC; FranciaFil: Bleurvacq, N.. APC; FranciaFil: Bordier, G.. APC; FranciaFil: Brossard, J.. APC; FranciaFil: Bunn, E. F.. Richmond University; Estados UnidosFil: Burke, D. P.. Maynooth University; IrlandaFil: Buzi, D.. Università degli Studi di Roma "La Sapienza"; ItaliaFil: Buzzelli, A.. Universita Tor Vergata; ItaliaFil: Cammilleri, D.. APC; FranciaFil: Cavaliere, F.. University of Milan; ItaliaFil: Chanial, P.. APC; FranciaFil: Etchegoyen, Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Tecnología en Detección y Astropartículas. Comisión Nacional de Energía Atómica. Instituto de Tecnología en Detección y Astropartículas. Universidad Nacional de San Martín. Instituto de Tecnología en Detección y Astropartículas; ArgentinaFil: Harari, Diego Dario. Comisión Nacional de Energía Atómica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Medina, Maria Clementina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Instituto Argentino de Radioastronomía. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto Argentino de Radioastronomía; ArgentinaFil: Romero, Gustavo Esteban. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Instituto Argentino de Radioastronomía. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto Argentino de Radioastronomía; ArgentinaFil: Suarez, Federico. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Tecnología en Detección y Astropartículas. Comisión Nacional de Energía Atómica. Instituto de Tecnología en Detección y Astropartículas. Universidad Nacional de San Martín. Instituto de Tecnología en Detección y Astropartículas; ArgentinaThe European Physical Society Conference on High Energy PhysicsVeneciaItaliaEuropean Physical Societ

    Observing galaxy clusters and the cosmic web through the Sunyaev Zel'dovich effect with MISTRAL

    Full text link
    Galaxy clusters and surrounding medium, can be studied using X-ray bremsstrahlung emission and Sunyaev Zel'dovich (SZ) effect. Both astrophysical probes, sample the same environment with different parameters dependance. The SZ effect is relatively more sensitive in low density environments and thus is useful to study the filamentary structures of the cosmic web. In addition, observations of the matter distribution require high angular resolution in order to be able to map the matter distribution within and around galaxy clusters. MISTRAL is a camera working at 90GHz which, once coupled to the Sardinia Radio Telescope, can reach 12′′12'' angular resolution over 4′4' field of view (f.o.v.). The forecasted sensitivity is NEFD≃10−15mJysNEFD \simeq 10-15mJy \sqrt{s} and the mapping speed is MS=380′2/mJy2/hMS= 380'^{2}/mJy^{2}/h. MISTRAL was recently installed at the focus of the SRT and soon will take its first photons.Comment: To appear in Proc. of the mm Universe 2023 conference, Grenoble (France), June 2023, published by F. Mayet et al. (Eds), EPJ Web of conferences, EDP Science

    The optical design of the Litebird middle and high frequency telescope

    Get PDF
    LiteBIRD is a JAXA strategic L-class mission devoted to the measurement of polarization of the Cosmic Microwave Background, searching for the signature of primordial gravitational waves in the B-modes pattern of the polarization. The onboard instrumentation includes a Middle and High Frequency Telescope (MHFT), based on a pair of cryogenically cooled refractive telescopes covering, respectively, the 89-224 GHz and the 166-448 GHz bands. Given the high target sensitivity and the careful systematics control needed to achieve the scientific goals of the mission, optical modeling and characterization are performed with the aim to capture most of the physical effects potentially affecting the real performance of the two refractors. We describe the main features of the MHFT, its design drivers and the major challenges in system optimization and characterization. We provide the current status of the development of the optical system and we describe the current plan of activities related to optical performance simulation and validation
    • …
    corecore