1,638 research outputs found
Auxiliary propulsion system flight package
Hughes Aircraft Company developed qualified and integrated flight, a flight test Ion Auxiliary Propulsion System (IAPS), on an Air Force technology satellite. The IAPS Flight Package consists of two identical Thruster Subsystems and a Diagnostic Subsystem. Each thruster subsystem (TSS) is comprised of an 8-cm ion Thruster-Gimbal-Beam Shield Unit (TGBSU); Power Electronics Unit; Digital Controller and Interface Unit (DCIU); and Propellant Tank, Valve and Feed Unit (PTVFU) plus the requisite cables. The Diagnostic Subsystem (DSS) includes four types of sensors for measuring the effect of the ion thrusters on the spacecraft and the surrounding plasma. Flight qualifications of IAPS, prior to installation on the spacecraft, consisted of performance, vibration and thermal-vacuum testing at the unit level, and thermal-vacuum testing at the subsystem level. Mutual compatibility between IAPS and the host spacecraft was demonstrated during a series of performance and environmental tests after the IAPS Flight Package was installed on the spacecraft. After a spacecraft acoustic test, performance of the ion thrusters was reverified by removing the TGBSUs for a thorough performance test at Hughes Research Laboratories (HRL). The TGBSUs were then reinstalled on the spacecraft. The IAPS Flight Package is ready for flight testing when Shuttle flights are resumed
Engineering model 8-cm thruster subsystem
An Engineering Model (EM) 8 cm Ion Thruster Propulsion Subsystem was developed for operation at a thrust level 5 mN (1.1 mlb) at a specific impulse 1 sub sp = 2667 sec with a total system input power P sub in = 165 W. The system dry mass is 15 kg with a mercury-propellant-reservoir capacity of 8.75 kg permitting uninterrupted operation for about 12,500 hr. The subsystem can be started from a dormant condition in a time less than or equal to 15 min. The thruster has a design lifetime of 20,000 hr with 10,000 startup cycles. A gimbal unit is included to provide a thrust vector deflection capability of + or - 10 degrees in any direction from the zero position. The EM subsystem development program included thruster optimization, power-supply circuit optimization and flight packaging, subsystem integration, and subsystem acceptance testing including a cyclic test of the total propulsion package
Narrowband frequency tunable light source of continuous quadrature entanglement
We report the observation of non-classical quantum correlations of continuous
light variables from a novel type of source. It is a frequency non-degenerate
optical parametric oscillator below threshold, where signal and idler fields
are separated by 740MHz corresponding to two free spectrum ranges of the
parametric oscillator cavity. The degree of entanglement observed, - 3.8 dB, is
the highest to-date for a narrowband tunable source suitable for atomic quantum
memory and other applications in atomic physics. Finally we use the latter to
visualize the Einstein-Podolsky-Rosen paradox.Comment: 11 pages, 9 figures, LaTe
Achromatizing a liquid-crystal spectropolarimeter: Retardance vs Stokes-based calibration of HiVIS
Astronomical spectropolarimeters can be subject to many sources of systematic
error which limit the precision and accuracy of the instrument. We present a
calibration method for observing high-resolution polarized spectra using
chromatic liquid-crystal variable retarders (LCVRs). These LCVRs allow for
polarimetric modulation of the incident light without any moving optics at
frequencies >10Hz. We demonstrate a calibration method using pure Stokes input
states that enables an achromatization of the system. This Stokes-based
deprojection method reproduces input polarization even though highly chromatic
instrument effects exist. This process is first demonstrated in a laboratory
spectropolarimeter where we characterize the LCVRs and show example
deprojections. The process is then implemented the a newly upgraded HiVIS
spectropolarimeter on the 3.67m AEOS telescope. The HiVIS spectropolarimeter
has also been expanded to include broad-band full-Stokes spectropolarimetry
using achromatic wave-plates in addition to the tunable full-Stokes
polarimetric mode using LCVRs. These two new polarimetric modes in combination
with a new polarimetric calibration unit provide a much more sensitive
polarimetric package with greatly reduced systematic error.Comment: Accepted in PAS
Variation between centres in access to renal transplantation in UK: longitudinal cohort study
Objective To assess whether equity exists in access to renal transplantation in the UK after adjustment for case mix in incident patients with end stage renal disease
Deriving Telescope Mueller Matrices Using Daytime Sky Polarization Observations
Telescopes often modify the input polarization of a source so that the
measured circular or linear output state of the optical signal can be
signficantly different from the input. This mixing, or polarization
"cross-talk", is defined by the optical system Mueller matrix. We describe here
an efficient method for recovering the input polarization state of the light
and the full 4 x 4 Mueller matrix of the telescope with an accuracy of a few
percent without external masks or telescope hardware modification. Observations
of the bright, highly polarized daytime sky using the Haleakala 3.7m AEOS
telescope and a coude spectropolarimeter demonstrate the technique.Comment: Accepted for publication in PAS
Problems and Aspects of Energy-Driven Wavefunction Collapse Models
Four problematic circumstances are considered, involving models which
describe dynamical wavefunction collapse toward energy eigenstates, for which
it is shown that wavefunction collapse of macroscopic objects does not work
properly. In one case, a common particle position measuring situation, the
apparatus evolves to a superposition of macroscopically distinguishable states
(does not collapse to one of them as it should) because each such
particle/apparatus/environment state has precisely the same energy spectrum.
Second, assuming an experiment takes place involving collapse to one of two
possible outcomes which is permanently recorded, it is shown in general that
this can only happen in the unlikely case that the two apparatus states
corresponding to the two outcomes have disjoint energy spectra. Next, the
progressive narrowing of the energy spectrum due to the collapse mechanism is
considered. This has the effect of broadening the time evolution of objects as
the universe evolves. Two examples, one involving a precessing spin, the other
involving creation of an excited state followed by its decay, are presented in
the form of paradoxes. In both examples, the microscopic behavior predicted by
standard quantum theory is significantly altered under energy-driven collapse,
but this alteration is not observed by an apparatus when it is included in the
quantum description. The resolution involves recognition that the statevector
describing the apparatus does not collapse, but evolves to a superposition of
macroscopically different states.Comment: 17 page
- …