60 research outputs found

    Development and validation of a novel non-contact monitor of nocturnal respiration for identifying sleep-disordered breathing in patients with heart failure

    Full text link
    © 2016 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology. Aims: At least 50% of patients with heart failure (HF) may have sleep-disordered breathing (SDB). Overnight in-hospital polysomnography (PSG) is considered the gold standard for diagnosis, but a lack of access to such testing contributes to under-diagnosis of SDB. Therefore, there is a need for simple and reliable validated methods to aid diagnosis in patients with HF. The aim of this study was to investigate the accuracy of a non-contact type IV screening device, SleepMinderTM (SM), compared with in-hospital PSG for detecting SDB in patients with HF. Methods and results: The study included 75 adult patients with systolic HF and suspected SDB who underwent simultaneous PSG and SM recordings. An algorithm was developed from the SM signals, using digital signal processing and pattern recognition techniques to calculate the SM apnoea-hypopnoea index (AHI). This was then compared with expert-scored PSGAHI. The SM algorithm had 70% sensitivity and 89% specificity for identifying patients with clinically significant SDB (AHI ≥ 15/h). At this threshold, it had a positive likelihood ratio of 6.3 and a negative likelihood ratio of 0.16. The overall accuracy of the SMAHI algorithm was 85.8% as shown by the area under a receiver operator characteristic curve. The mean AHI with SM was 3.8/h (95% confidence interval 0.5–7.1) lower than that with PSG. Conclusions: The accuracy of the non-contact type IV screening device SM is good for clinically significant SDB in patients with systolic HF and could be considered as a simple first step in the diagnostic pathway

    New information on the corroboree frog (Pseudophryne corroboree Moore)

    No full text
    Volume: 80Start Page: 258End Page: 26

    A preliminary investigation of the natural history of the tiger flathead (Neoplatycephalus macrodon) on the south-eastern Australian coast. I

    No full text
    Volume: 59Start Page: 71End Page: 9

    The marine plankton of the coastal waters of New South Wales. I. The chief planktonic forms and their seasonal distribution

    No full text
    Volume: 58Start Page: 186End Page: 22

    Ueber die Flüchtigkeit der Schwefelsäure bei gewöhnlicher Temperatur

    No full text

    Feasibility of Using Small UAVs to Derive Morphometric Measurements of Australian Snubfin (Orcaella heinsohni) and Humpback (Sousa sahulensis) Dolphins

    No full text
    Analysis of animal morphometrics can provide vital information regarding population dynamics, structure, and body condition of cetaceans. Unmanned aerial vehicles (UAVs) have become the primary tool to collect morphometric measurements on whales, whereas on free ranging small dolphins, have not yet been applied. This study assesses the feasibility of obtaining reliable body morphometrics from Australian snubfin (Orcaella heinsohni) and humpback dolphins (Sousa sahulensis) using images collected from UAVs. Specifically, using a dolphin replica of known size, we tested the effect of the altitude of the UAV and the position of the animal within the image frame on the accuracy of length estimates. Using linear mixed models, we further assessed the precision of the total length estimates of humpback and snubfin dolphins. The precision of length estimates on the replica increased by ~2% when images were sampled at 45–60 m compared with 15–30 m. However, the precision of total length estimates on dolphins was significantly influenced only by the degree of arch and edge certainty. Overall, we obtained total length estimates with a precision of ~3% and consistent with published data. This study demonstrates the reliability of using UAV based images to obtain morphometrics of small dolphin species, such as snubfin and humpback dolphins
    corecore