871 research outputs found
Recommended from our members
An integrated approach for the in vitro dosimetry of engineered nanomaterials
Background: There is a great need for screening tools capable of rapidly assessing nanomaterial toxicity. One impediment to the development of reliable in vitro screening methods is the need for accurate measures of cellular dose. We present here a methodology that enables accurate determination of delivered to cell dose metrics. This methodology includes (1) standardization of engineered nanomaterial (ENM) suspension preparation; (2) measurement of ENM characteristics controlling delivery to cells in culture; and (3) calculation of delivered dose as a function of exposure time using the ISDD model. The approach is validated against experimentally measured doses, and simplified analytical expressions for the delivered dose (Relevant In Vitro Dose (RID)f function) are derived for 20 ENMs. These functions can be used by nanotoxicologists to accurately calculate the total mass (RIDM), surface area (RIDSA), or particle number (RIDN) delivered to cells as a function of exposure time. Results: The proposed methodology was used to derive the effective density, agglomerate diameter and RID functions for 17 industrially-relevant metal and metal oxide ENMs, two carbonaceous nanoparticles, and non-agglomerating gold nanospheres, for two well plate configurations (96 and 384 well plates). For agglomerating ENMs, the measured effective density was on average 60% below the material density. We report great variability in delivered dose metrics, with some materials depositing within 24 hours while others require over 100 hours for delivery to cells. A neutron-activated tracer particle system was employed to validate the proposed in vitro dosimetry methodology for a number of ENMs (measured delivered to cell dose within 9% of estimated). Conclusions: Our findings confirm and extend experimental and computational evidence that agglomerate characteristics affect the dose delivered to cells. Therefore measurement of these characteristics is critical for effective use of in vitro systems for nanotoxicology. The mixed experimental/computational approach to cellular dosimetry proposed and validated here can be used by nanotoxicologists to accurately calculate the delivered to cell dose metrics for various ENMs and in vitro conditions as a function of exposure time. The RID functions and characterization data for widely used ENMs presented here can together be used by experimentalists to design and interpret toxicity studies
Pulsed excitation dynamics of an optomechanical crystal resonator near its quantum ground-state of motion
Using pulsed optical excitation and read-out along with single phonon
counting techniques, we measure the transient back-action, heating, and damping
dynamics of a nanoscale silicon optomechanical crystal cavity mounted in a
dilution refrigerator at a base temperature of 11mK. In addition to observing a
slow (~740ns) turn-on time for the optical-absorption-induced hot phonon bath,
we measure for the 5.6GHz `breathing' acoustic mode of the cavity an initial
phonon occupancy as low as 0.021 +- 0.007 (mode temperature = 70mK) and an
intrinsic mechanical decay rate of 328 +- 14 Hz (mechanical Q-factor =
1.7x10^7). These measurements demonstrate the feasibility of using short pulsed
measurements for a variety of quantum optomechanical applications despite the
presence of steady-state optical heating.Comment: 16 pages, 6 figure
Optical coupling to nanoscale optomechanical cavities for near quantum-limited motion transduction
A significant challenge in the development of chip-scale cavity-optomechanical devices as testbeds for quantum experiments and classical metrology lies in the coupling of light from nanoscale optical mode volumes to conventional optical components such as lenses and fibers. In this work we demonstrate a high-efficiency, single-sided fiber-optic coupling platform for optomechanical cavities. By utilizing an adiabatic waveguide taper to transform a single optical mode between a photonic crystal zipper cavity and a permanently mounted fiber, we achieve a collection efficiency for intracavity photons of 52% at the cavity resonance wavelength of λ ≈ 1538 nm. An optical balanced homodyne measurement of the displacement fluctuations of the fundamental in-plane mechanical resonance at 3.3 MHz reveals that the imprecision noise floor lies a factor of 2.8 above the standard quantum limit (SQL) for continuous position measurement, with a predicted total added noise of 1.4 phonons at the optimal probe power. The combination of extremely low measurement noise and robust fiber alignment presents significant progress towards single-phonon sensitivity for these sorts of integrated micro-optomechanical cavities
Social Exclusion Modifies Climate and Deforestation Impacts on a Vector-Borne Disease
American Cutaneous Leishmaniasis emergence has been associated with changes in the interaction between people and forests. The association between outbreaks and forest clearance, higher risk for populations living close to forests, and the absence of this disease from urban settings has led to the proposal that it will disappear with the destruction of primary forests. This view ignores the complex nature of deforestation as a product of socioeconomic inequities. Our study shows that such inequities, as measured by a marginalization index, may ultimately determine risk within the country, with socially excluded populations most affected by the disease. Contrary to the established view, living close to the forest edge can diminish the risk provided other factors are taken into account. Additionally, differences in vulnerability to climatic variability appear to interact with forest cover to influence risk across counties where the disease has its largest burden. Incidence exacerbation associated with El Niño Southern Oscillation is observed in counties with larger proportions of deforestation. Our study calls for control efforts targeted to socially excluded populations and for more localized ecological studies of transmission in vectors and reservoirs in order to understand the role of biodiversity changes in driving the emergence of this disease
Utilizing Dynamic Tensiometry to Quantify Contact Angle Hysteresis and Wetting State Transitions on Nonwetting Surfaces
Goniometric techniques traditionally quantify two parameters, the advancing and receding contact angles, that are useful for characterizing the wetting properties of a solid surface; however, dynamic tensiometry, which measures changes in the net force on a surface during the repeated immersion and emersion of a solid into a probe liquid, can provide further insight into the wetting properties of a surface. We detail a framework for analyzing tensiometric results that allows for the determination of wetting hysteresis, wetting state transitions, and characteristic topographical length scales on textured, nonwetting surfaces, in addition to the more traditional measurement of apparent advancing and receding contact angles. Fluorodecyl POSS, a low-surface-energy material, was blended with commercially available poly(methyl methacrylate) (PMMA) and then dip- or spray-coated onto glass substrates. These surfaces were probed with a variety of liquids to illustrate the effects of probe liquid surface tension, solid surface chemistry, and surface texture on the apparent contact angles and wetting hysteresis of nonwetting surfaces. Woven meshes were then used as model structured substrates to add a second, larger length scale for the surface texture. When immersed into a probe liquid, these spray-coated mesh surfaces can form a metastable, solid–liquid–air interface on the largest length scale of surface texture. The increasing hydrostatic pressure associated with progressively greater immersion depths disrupts this metastable, composite interface and forces penetration of the probe liquid into the mesh structure. This transition is marked by a sudden change in the wetting hysteresis, which can be systematically probed using spray-coated, woven meshes of varying wire radius and spacing. We also show that dynamic tensiometry can accurately and quantitatively characterize topographical length scales that are present on microtextured surfaces.United States. Air Force Office of Scientific Research (W 911NF-07-D-0004
Generation of phase-matched circularly-polarized extreme ultraviolet high harmonics for magnetic circular dichroism spectroscopy
Circularly-polarized extreme UV and X-ray radiation provides valuable access
to the structural, electronic and magnetic properties of materials. To date,
this capability was available only at large-scale X-ray facilities such as
synchrotrons. Here we demonstrate the first bright, phase-matched, extreme UV
circularly-polarized high harmonics and use this new light source for magnetic
circular dichroism measurements at the M-shell absorption edges of Co. We show
that phase matching of circularly-polarized harmonics is unique and robust,
producing a photon flux comparable to the linearly polarized high harmonic
sources that have been used very successfully for ultrafast element-selective
magneto-optic experiments. This work thus represents a critical advance that
makes possible element-specific imaging and spectroscopy of multiple elements
simultaneously in magnetic and other chiral media with very high spatial and
temporal resolution, using tabletop-scale setups.Comment: 12 text pages, 4 figures, supplamentary information 6 page
Generation of bright phase-matched circularly-polarized extreme ultraviolet high harmonics
Circularly-polarized extreme ultraviolet and X-ray radiation is useful for analysing the structural, electronic and magnetic properties of materials. To date, such radiation has only been available at large-scale X-ray facilities such as synchrotrons. Here, we demonstrate the first bright, phase-matched, extreme ultraviolet circularly-polarized high harmonics source. The harmonics are emitted when bi-chromatic counter-rotating circularly-polarized laser pulses field-ionize a gas in a hollow-core waveguide. We use this new light source for magnetic circular dichroism measurements at the M-shell absorption edges of Co. We show that phase-matching of circularly-polarized harmonics is unique and robust, producing a photon flux comparable to linearly polarized high harmonic sources. This work represents a critical advance towards the development of table-top systems for element-specific imaging and spectroscopy of multiple elements simultaneously in magnetic and other chiral media with very high spatial and temporal resolution. Circularly-polarized radiation in the extreme ultraviolet (EUV)and soft X-ray spectral regions has proven to be extremelyuseful for investigating chirality-sensitive light–matter inter-actions. It enables studies of chiral molecules using photoelectron circular dichroism1, ultrafast molecular decay dynamics2, the direct measurement of quantum phases (for example, Berry’s phase and pseudo-spin) in graphene and topological insulators3,4 and reconstruction of band structure and modal phases in solids5
Multiplicities of Periodic Orbit Lengths for Non-Arithmetic Models
Multiplicities of periodic orbit lengths for non-arithmetic Hecke triangle
groups are discussed. It is demonstrated both numerically and analytically that
at least for certain groups the mean multiplicity of periodic orbits with
exactly the same length increases exponentially with the length. The main
ingredient used is the construction of joint distribution of periodic orbits
when group matrices are transformed by field isomorphisms. The method can be
generalized to other groups for which traces of group matrices are integers of
an algebraic field of finite degree
Measuring Stellar Radial Velocities with a Dispersed Fixed-Delay Interferometer
We demonstrate the ability to measure precise stellar barycentric radial
velocities with the dispersed fixed-delay interferometer technique using the
Exoplanet Tracker (ET), an instrument primarily designed for precision
differential Doppler velocity measurements using this technique. Our
barycentric radial velocities, derived from observations taken at the KPNO 2.1
meter telescope, differ from those of Nidever et al. by 0.047 km/s (rms) when
simultaneous iodine calibration is used, and by 0.120 km/s (rms) without
simultaneous iodine calibration. Our results effectively show that a Michelson
interferometer coupled to a spectrograph allows precise measurements of
barycentric radial velocities even at a modest spectral resolution of R ~ 5100.
A multi-object version of the ET instrument capable of observing ~500 stars per
night is being used at the Sloan 2.5 m telescope at Apache Point Observatory
for the Multi-object APO Radial Velocity Exoplanet Large-area Survey (MARVELS),
a wide-field radial velocity survey for extrasolar planets around TYCHO-2 stars
in the magnitude range 7.6<V<12. In addition to precise differential
velocities, this survey will also yield precise barycentric radial velocities
for many thousands of stars using the data analysis techniques reported here.
Such a large kinematic survey at high velocity precision will be useful in
identifying the signature of accretion events in the Milky Way and
understanding local stellar kinematics in addition to discovering exoplanets,
brown dwarfs and spectroscopic binaries.Comment: 9 pages, 4 figures. Accepted for publication in Ap
- …