3 research outputs found

    Availability Performances of Ground-Coupled Heat Pump Systems

    No full text
    The paper presents aspects regarding the reliability and availability of ground-coupled heat pump systems (GCHP). Basic concepts of predictive reliability are introduced and the two modes of reliability analyses (quantitative and qualitative) are shown specifically for PCSS. In order to be able to model the availability of GCHP systems, global reliability indicators must be determined. Furthermore, failure manners and their effects on system reliability, as well as the graphical-analytical methods that could be applied to GCHP systems are analyzed. Finally, a case study for the experimental system installed in Thermodynamics Laboratory belonging to Energy Engineering Faculty is shown

    Energy Performance Analysis of the first Research-only Ground Coupled Heat Pump in Romania

    No full text
    One laboratory belonging to Energy Engineering Faculty is heated with a ground-coupled heat pump (GCHP) system having two types of ground heat exchangers: a vertical one and a horizontal one. This paper presents, at first, several coefficients of performance that can be defined for heat pumps together with their usability. Then, an energy efficiency model is set specially for CGHP systems. In this paper the simulation of energy performances is done only for the vertical heat exchanger (borehole heat exchanger) having two configurations: single-U and double-U. All simulation results range between normal values and can be considered realistic

    Energy Performance Analysis of a Heat Supply System of a University Campus

    No full text
    The energy efficiency of a system and the performance level of its equipment and installations are the two key elements based on which the investment decision in its modernization is made. They are also very important for setting up optimal operation strategies. The energy audit is a well-known and worldwide recognized tool for calculating energy performance indicators and developing improvement measures. This paper is a synthesis of the energy audit results performed for a district heating network that uses geothermal energy as its primary source of energy. The location of the heating system is inside a university campus. The first part explains the necessity of a comprehensive study on district heating networks and introduces the defining elements that characterize the analyzed equipment and installations. The complex energy balance methodology that has been developed and applied to this district heating system is presented in the second part of the paper. Next, the methodology for collecting the input data for the energy and mass balance is explained. In the final part, the numerical values of the performance indicators and the technical measures that must be applied to improve energy efficiency are shown, and conclusions are drawn
    corecore