8 research outputs found

    Dynamic frictional behaviour of orthodontic archwires and brackets

    No full text

    Dynamic frictional behaviour of orthodontic archwires and brackets

    No full text
    The aim of this study was to evaluate the frictional behaviour of 15 different archwires and 16 different brackets using small oscillating displacements when opposed to a standard stainless steel bracket or a standard stainless steel wire. Tests were run according to a pilot study at a frequency of 1 Hz and with a reciprocating tangential displacement of 200 microm, while the wire remained centred in the bracket slot under a load of 2 N. The results indicated a significant difference between the evaluated wires and brackets. The mean coefficient of friction (COF) of the wires varied from 0.16 for Imagination NiTi tooth-coloured wire to 0.69 for the True Chrome Resilient Purple wire, while for the brackets it ranged from 0.39 for Ultratrimm to 0.72 for the Master Series. The fact that in this study, a large number of different commercially available archwires and brackets were evaluated with the same apparatus according to the same protocol, allows a direct comparison of the different archwire and bracket combinations, and can assist in the choice of the optimal bracket-wire combination with regard to friction.status: publishe

    Frictional behavior of stainless steel bracket-wire combinations subjected to small oscillating displacements

    No full text
    In orthodontic treatment, sliding is frequently used to cause tooth movement. Inherent to this technique is the generation of a counteracting frictional force. In this pilot study, a fretting test consisting of reciprocating tangential displacements was used to investigate test parameters influencing frictional forces during sliding processes. Tests were run at a normal load of 2 N and a frequency of 1 Hz for tangential displacement strokes of 200 microm. Stainless steel orthodontic wires with cross-sections of .017 x .025 in (W17) and .018 x .025 in (W18), and brackets with slot sizes of .018 in (B18) and .022 in (B22) were used. A specific centered positioning method was developed to achieve a parallel alignment of the wire and the bracket slot. The experimental results indicated the significant role of the centered positioning method on the friction value. Implementation of the centered positioning method resulted in a friction force ranging from 0.89 N to 0.97 N at a 200 microm displacement amplitude and 1 Hz frequency, corresponding to a coefficient of friction ranging from 0.45 to 0.49 for the B18-W17 and the B22-W17 bracket-wire combinations, respectively. When the centered positioning method was not used, significantly higher values for the coefficient of friction were found for both bracket-wire combinations. The slot-filling, bracket-wire combinations (B18-W18 and B22-W22) resulted in an increased coefficient of friction and therefore are not recommended as sliding systems.status: publishe
    corecore