112 research outputs found
Rheological properties of porcine organs: measurements and fractional viscoelastic model
The rheological properties of porcine heart, kidney, liver and brain were measured using dynamic oscillatory shear tests over a range of frequencies and shear strains. Frequency sweep tests were performed from 0.1 Hz to a maximum of 9.5 Hz at a shear strain of 0.1%, and strain sweep tests were carried out from 0.01% to 10% at 1 Hz. The effect of pre-compression of samples up to 10% axial strain was considered. The experimental measurements were fit to a Semi-Fractional Kelvin Voight (S-FKV) model. The model was then used to predict the stress relaxation in response to a step strain of 0.1%. The prediction was compared to experimental relaxation data for the porcine organ samples, and the results agreed to within 30%. In conclusion, this study measured the rheological properties of porcine organs and used a fractional viscoelastic model to describe the response in frequency and time domain
Biomechanical Modelling of Porcine Kidney
In this study, the viscoelastic properties of porcine kidney in the upper, middle and lower poles were investigated using oscillatory shear tests. The viscoelastic properties were extracted in the form of the storage modulus and loss modulus in the frequency and time domain. Measurements were taken as a function of frequency from 0.1 Hz to 6.5 Hz at a shear strain amplitude of 0.01 and as function of strain amplitude from 0.001 to 0.1 at a frequency of 1 Hz. Measurements were also taken in the time domain in response to a step shear strain. Both the frequency and time domain data were fitted to a conventional Standard Linear Solid (SLS) model and a semi-fractional Kelvin–Voigt (SFKV) model with a comparable number of parameters. The SFKV model fitted the frequency and time domain data with a correlation coefficient of 0.99. Although the SLS model well fitted the time domain data and the storage modulus data in the frequency domain, it was not able to capture the variation in loss modulus with frequency with a correlation coefficient of 0.53. A five parameter Maxwell–Wiechert model was able to capture the frequency dependence in storage modulus and loss modulus better than the SLS model with a correlation of 0.85
Time domain simulation of nonlinear acoustic beams generated by rectangular pistons with application to harmonic imaging
This is the published version. Copyright 2005 Acoustical Society of AmericaA time-domain numerical code (the so-called Texas code) that solves the Khokhlov–Zabolotskaya–Kuznetsov (KZK) equation has been extended from an axis-symmetric coordinate system to a three-dimensional (3D) Cartesian coordinate system. The code accounts for diffraction (in the parabolic approximation), nonlinearity and absorption and dispersion associated with thermoviscous and relaxation processes. The 3D time domain code was shown to be in agreement with benchmark solutions for circular and rectangular sources, focused and unfocused beams, and linear and nonlinear propagation. The 3D code was used to model the nonlinear propagation of diagnosticultrasound pulses through tissue. The prediction of the second-harmonic field was sensitive to the choice of frequency-dependent absorption: a frequency squared f2 dependence produced a second-harmonic field which peaked closer to the transducer and had a lower amplitude than that computed for an f1.1 dependence. In comparing spatial maps of the harmonics we found that the second harmonic had dramatically reduced amplitude in the near field and also lower amplitude side lobes in the focal region than the fundamental. These findings were consistent for both uniform and apodized sources and could be contributing factors in the improved imaging reported with clinical scanners using tissue harmonic imaging
The Application of Clinical Lithotripter Shock Waves to RNA Nucleotide Delivery to Cells
AbstractThe delivery of genes into cells through the transfer of ribonucleic acids (RNAs) has been found to cause a change in the level of target protein expression. RNA-based transfection is conceptually more efficient than commonly delivered plasmid DNA because it does not require division or damage of the nuclear envelope, thereby increasing the chances of the cell remaining viable. Shock waves (SWs) have been found to induce cellular uptake by transiently altering the permeability of the plasma membrane, thereby overcoming a critical step in gene therapy. However, accompanying SW bio-effects include dose-dependent irreversible cell injury and cytotoxicity. Here, the effect of SWs generated by a clinical lithotripter on the viability and permeabilisation of three different cell lines in vitro was investigated. Comparison of RNA stability before and after SW exposure revealed no statistically significant difference. Optimal SW exposure parameters were identified to minimise cell death and maximise permeabilisation, and applied to enhanced green fluorescent protein (eGFP) messenger RNA (mRNA) or anti-eGFP small interfering RNA delivery. As a result, eGFP mRNA expression levels increased up to 52-fold in CT26 cells, whereas a 2-fold decrease in GFP expression was achieved after anti-eGFP small interfering RNA delivery to MCF-7/GFP cells. These results indicate that SW parameters can be employed to achieve effective nucleotide delivery, laying the foundation for non-invasive and high-tolerability RNA-based gene therapy
On measuring the acoustic state changes in lipid membranes using fluorescent probes
Ultrasound is increasingly being used to modulate the properties of
biological membranes for applications in drug delivery and neuromodulation.
While various studies have investigated the mechanical aspect of the
interaction such as acoustic absorption and membrane deformation, it is not
clear how these effects transduce into biological functions, for example,
changes in the permeability or the enzymatic activity of the membrane. A
critical aspect of the activity of an enzyme is the thermal fluctuations of its
solvation or hydration shell. Thermal fluctuations are also known to be
directly related to membrane permeability. Here solvation shell changes of
lipid membranes subject to an acoustic impulse were investigated using a
fluorescence probe, Laurdan. Laurdan was embedded in multi-lamellar lipid
vesicles in water, which were exposed to broadband pressure impulses of the
order of 1MPa peak amplitude and 10{\mu}s pulse duration. An instrument was
developed to monitor changes in the emission spectrum of the dye at two
wavelengths with sub-microsecond temporal resolution. The experiments show that
changes in the emission spectrum, and hence the fluctuations of the solvation
shell, are related to the changes in the thermodynamic state of the membrane
and correlated with the compression and rarefaction of the incident sound wave.
The results suggest that acoustic fields affect the state of a lipid membrane
and therefore can potentially modulate the kinetics of channels and proteins
embedded in the membrane
Design and characterization of a research electrohydraulic lithotripter patterned after the Dornier HM3
An electrohydraulic lithotripter has been designed that mimics the behavior of the Dornier HM3 extracorporeal shock wave lithotripter. The key mechanical and electrical properties of a clinical HM3 were measured and a design implemented to replicate these parameters. Three research lithotripters have been constructed on this design and are being used in a multi-institutional, multidisciplinary research program to determine the physical mechanisms of stone fragmentation and tissue damage in shock wave lithotripsy. The acoustic fields of the three research lithotripters and of two clinical Dornier HM3 lithotripters were measured with a PVDF membrane hydrophone. The peak positive pressure, peak negative pressure, pulse duration, and shock rise time of the focal waveforms were compared. Peak positive pressures varied from 25 MPa at a voltage setting of 12 kV to 40 MPa at 24 kV. The magnitude of the peak negative pressure varied from -7 to -12 MPa over the same voltage range. The spatial variations of the peak positive pressure and peak negative pressure were also compared. The focal region, as defined by the full width half maximum of the peak positive pressure, was 60 mm long in the axial direction and 10 mm wide in the lateral direction. The performance of the research lithotripters was found to be consistent at clinical firing rates (up to 3 Hz). The results indicated that pressure fields in the research lithotripters are equivalent to those generated by a clinical HM3 lithotripter
Effect of stratification and geometrical spreading on sonic boom rise time
The purpose of our investigation is to determine the effect of unsteadiness (not associated with turbulence) on rise time. The unsteadiness considered here is due to (1) geometrical spreading, (2) stratification, which includes variation in density, temperature, and relative humidity, and (3) N shaped waveform. A very general Burgers equation, which includes all these effects, is the propagation model for our study. The equation is solved by a new computational algorithm in which all the calculations are done in the time domain. The present paper is a progress report in which some of the factors contributing to unsteadiness are studied, namely geometrical spreading and variation in relative humidity. The work of Pierce and Kang, which motivated our study, is first reviewed. We proceed with a discussion of the Burgers equation model and the algorithm for solving the equation. Some comparison tests to establish the validity of the algorithm are presented. The algorithm is then used to determine the distance required for a steady-state shock, on encountering an abrupt change in relative humidity, to reach a new steady state based on the new humidity. It is found that the transition distance for plane shocks of amplitude 70 Pa is about 4 km when the change in relative humidity is 10 percent. Shocks of amplitude 140 Pa require less distance. The effect of spherical and cylindrical spreading is also considered. We demonstrate that a spreading shock wave never reaches steady state and that its rise time will be less than the equivalent steady state shock. Finally we show that an N wave has a slightly shorter rise time than a step shock of the same amplitude
Sparsity driven ultrasound imaging
An image formation framework for ultrasound imaging from synthetic transducer arrays based on sparsity-driven regularization functionals using single-frequency Fourier domain data is proposed. The framework involves the use of a physics-based forward model of the ultrasound observation process, the formulation of image formation as the solution of an associated optimization problem, and the solution of that problem through efficient numerical algorithms. The sparsity-driven, model-based approach estimates a complex-valued reflectivity field and preserves physical features in the scene while suppressing spurious artifacts. It also provides robust reconstructions in the case of sparse and reduced observation apertures. The effectiveness of the proposed imaging strategy is demonstrated using experimental data
- …