12 research outputs found

    Validation of the Dutch-language version of Nurses' Moral Courage Scale

    Get PDF
    Background:Moral courage as a part of nurses' moral competence has gained increasing interest as a means to strengthen nurses acting on their moral decisions and offering alleviation to their moral distress. To measure and assess nurses' moral courage, the development of culturally and internationally validated instruments is needed.Objective:The objective of this study was to validate the Dutch-language version of the four-component Nurses' Moral Courage Scale originally developed and validated in Finnish data.Research design:This methodological study used non-experimental, cross-sectional exploratory design.Participants and research context:A total of 559 nurses from two hospitals in Flanders, Belgium, completed the Dutch-language version of the Nurses' Moral Courage Scale.Ethical considerations:Good scientific inquiry guidelines were followed throughout the study. Permission to translate the Nurses' Moral Courage Scale was obtained from the copyright holder, and the ethical approval and permissions to conduct the study were obtained from the participating university and hospitals, respectively.Findings:The four-component 21-item, Dutch-language version of the Nurses' Moral Courage Scale proved to be valid and reliable as the original Finnish Nurses' Moral Courage Scale. The scale's internal consistency reliability was high (0.91) corresponding with the original Nurses' Moral Courage Scale validation study (0.93). The principal component analysis confirmed the four-component structure of the original Nurses' Moral Courage Scale to be valid also in the Belgian data explaining 58.1% of the variance. Confirmatory factor analysis based on goodness-of-fit indices provided evidence of the scale's construct validity. The use of a comparable sample of Belgian nurses working in speciality care settings as in the Finnish study supported the stability of the structure.Discussion and conclusion:The Dutch-language version of the Nurses' Moral Courage Scale is a reliable and valid instrument to measure nurses' self-assessed moral courage in speciality care nursing environments. Further validation studies in other countries, languages and nurse samples representing different healthcare environments would provide additional evidence of the scale's validity and initiatives for its further development.</div

    A monocentric retrospective study of 138 therapy-related myeloid neoplasms

    No full text
    As diagnosing therapy-related myeloid neoplasms (t-MN) is often challenging, we reviewed clinicopathological features of t-MN patients. Medical records of 138 patients, diagnosed with t-MN between 1995 and 2017, were reviewed. Of 138 patients, 80 had t-MDS, 53 t-AML, and 5 t-MDS/MPN (age, 22-88 years; median 64 years; male/female ratio, 0.8). The median latency time was 6 years and 5 months. Of 115 patients, 56 patients received cytotoxic-/radiotherapy for a solid tumor, 56 for hematological malignancy, and 3 for an auto-immune disorder, respectively. Another 21 patients had a combination of 2 disorders. Moreover, 2 patients had 3 previous malignancies. Breast cancer was the most prevalent tumor, followed by low-grade B non-Hodgkin lymphoma. Immunophenotyping and immunohistochemistry showed aberrant expression of B-, T-, or NK-cell markers in 21% and 6%, respectively. In 90% of the patients, dysplasia in ≥ 1 lineage was found. KMT2A fusion gene transcripts were seen in 5%. Cytogenetic analysis showed complex karyotypes (31%) and chromosome 5 and/or 7 abnormalities (40%). Almost 82% of the patients died and the median overall survival was about 1 year. Our study confirms that previous therapy for breast cancer is the most important cause of t-MN. KMT2A fusion genes are prevalent and complex karyotypes and/or chromosomes 5 and/or 7 abnormalities are common.status: publishe

    The integration of Sysmex XN-9100' WPC channel reflex testing in the detection of reactive versus malignant blood samples

    No full text
    INTRODUCTION: Sysmex XN-9100™ (Sysmex, Kobe, Japan) system has an optional White Progenitor Cell (WPC) channel. While the White Differentiation (WDF) channel reports a combined flag for blasts/abnormal lymphocytes, WPC channel specifies flagging into a separate flag for each cell type or removes the flag entirely. Aim of this study was to evaluate the added value of this WPC channel in the detection of malignant samples. METHODS: Routine blood samples analyzed on Sysmex XE-5000 with flagging for either blasts, abnormal lymphocytes, or atypical lymphocytes (n = 630) were selected for testing on Sysmex XN-9100, resulting in a reflex WPC analysis in 420 samples. All samples were microscopically evaluated with DI-60 digital cell imaging analyzer. RESULTS: WPC reflex testing resulted in a suspect flag ("blasts" and/or "abnormal lymphocytes") in 334 samples, which was confirmed microscopically in 38% (128/334). In all true positive samples, WPC correctly classified the initial WDF flag in either "blasts" flag or "abnormal lymphocytes?" flag in 75%. Only 12% (50/420) of WDF "blasts/abnormal lymphocytes" positive samples became negative after WPC reflex testing. Subgroup analysis showed differences between the "pediatric" versus "adult" groups and the "hematological/chemotherapy" versus "nonhematological/nonchemotherapy" groups in specificity and smear reduction. CONCLUSION: Overall, WPC reflex testing showed good sensitivity (99%); however, the specificity remains poor (29%). Using reflex WPC to the WDF channel resulted in a 12% reduction of the smear review rate. Although the WPC channel offers different interesting advantages, additional topics and a specific workflow should be applied to optimize the use of this channel.status: publishe

    Evaluation of the Sebia Minicap Flex Piercing capillary electrophoresis for hemoglobinopathy testing

    No full text
    INTRODUCTION: Capillary zone electrophoresis (CZE) at alkaline pH is one of the techniques used for hemoglobinopathy screening. In this study, an evaluation of the performance of a lower throughput CZE instrument, the Sebia Minicap Flex Piercing system, for this purpose is reported for the first time. METHODS: The analytical performance of the Sebia Minicap Flex Piercing system was evaluated. Furthermore, a method comparison between the Sebia Minicap Flex Piercing and two HPLC methods, that is, the Bio-Rad Variant Classic(™) and the Bio-Rad D-10(™) systems was performed by measuring samples with and without clinically relevant hemoglobin disorders. RESULTS: The analytical performance was acceptable for the determination of HbA, HbA2, HbS, and HbF, with an imprecision ≤2.0%. Method comparison showed a linear correlation for HbA2, HbF, and HbS measurements. Clinical concordance was acceptable when comparing CZE and HPLC. CONCLUSIONS: Lower throughput CZE using the Sebia Minicap Flex Piercing can be used for precise and accurate first line screening and follow-up of hemoglobinopathies.published_online: 2014-10-13status: publishe

    Isolated sulfite oxidase deficiency

    No full text
    Isolated sulfite oxidase deficiency (ISOD) is a life-threatening, autosomal recessive disease characterized by severe neurological impairment. As no long-term effective treatment is available, distinction from other treatable diseases, such as molybdenum cofactor deficiency (MoCD) type A, should be made. We reviewed 47 patients (45 previously reported in the literature). Cases were reviewed for consanguinity, sex, age at onset, death, clinical findings (including spasticity, seizures, psychomotor retardation, feeding difficulties, ectopia lentis, microcephaly), laboratory findings [urinary sulfite, S-sulfocysteine (in plasma and urine), plasma cystine, total homocysteine, uric acid, and oxypurines in urine] and radiological findings (including cerebral/cerebellar atrophy, cystic white matter changes, ventriculomegaly). We also aligned the published SUOX gene mutations to the reference sequence NM_000456.2. Onset occurred mostly during the first 72 h of life (57%) and within the first year of life in all but two patients (96%). All patients presented with neurological abnormalities, such as neonatal axial hypotonia and/or peripheral hypertonia (100%), (pharmacoresistant) seizures (84%), or developmental delay (97%). Feeding problems were also common. As found in our review, measurement of homocysteine in plasma, amino acids in plasma/urine, and sulfite in fresh urine supports the diagnosis of ISOD. Analysis of uric acid (plasma) and oxypurines (urine) is useful to rule out MoCD. In all patients in whom brain magnetic resonance imaging/computed tomography (MRI/CT) was performed, brain abnormalities were found. The purpose of this literature review is to provide a thorough overview of clinical, neuroimaging, biochemical, and genetic findings of patients with ISOD.status: publishe

    Clinicopathological characteristics of de novo and secondary myeloid sarcoma: a monocentric retrospective study

    No full text
    Diagnosing myeloid sarcoma remains challenging and we aimed to provide clinicopathological features to facilitate diagnosis.status: accepte

    Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting

    No full text
    BACKGROUND: We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU). METHODS: Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform II (Roche) were evaluated for recovery/linearity, imprecision/repeatability. The GMs and the ABL90 (Radiometer) blood gas analyzer (BGA) were tested for relative accuracy vs. the comparator hexokinase glucose-6-phosphate-dehydrogenase (HK/G6PDH) assay on a Cobas c702 analyzer (Roche). RESULTS: Recovery of spiked glucose was linear up to 19.3 mmol/L (347 mg/dL) with a slope of 0.91-0.94 for all GMs. Repeatability estimated by pooling duplicate measurements on samples below (n=9), in (n=51) or above (n=80) the 4.2-5.9 mM (74-106 mg/dL) range were for Freestyle Precision Pro: 4.2%, 4.0%, 3.6%; StatStrip Connectivity Meter: 4.0%, 4.3%, 4.5%; and ACCU-CHEK Inform II: 1.4%, 2.5%, 3.5%. GMs were in agreement with the comparator method. The BGA outperformed the GMs, with a MARD of 3.9% compared to 6.5%, 5.8% and 4.4% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. Zero % of the BGA results deviated more than the FDA 10% criterion as compared to 9.4%, 3.7% and 2.2% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. For all GMs, icodextrin did not interfere. Variation in the putative influence factors hematocrit and O2 tension could not explain observed differences with the comparator method. CONCLUSIONS: GMs quantified blood glucose in whole blood at about the 10% total error criterion, proposed by the FDA for prescription use.status: publishe