5 research outputs found

    Enhanced response of the fricke solution doped with hematoporphyrin under X-rays irradiation

    Get PDF
    The vials filled with Fricke solutions were doped with increasing concentrations of Photogem®, used in photodynamic therapy. These vials were then irradiated with low-energy X-rays with doses ranging from 5 to 20 Gy. The conventional Fricke solution was also irradiated with the same doses. The concentration of ferric ions for the Fricke and doped-Fricke irradiated solutions were measured in a spectrophotometer at 220 to 340 nm. The results showed that there was an enhancement in the response of the doped-Fricke solution, which was proportional to the concentration of the photosensitizer. The use of such procedure for studying the radiosensitizing property of photosensitizers based on the production of free radicals is also discussed.Tubos de ensaio foram preenchidos com a solução Fricke dopada com Fotogem® em concentrações crescentes; essa hemotoporfirina é utilizada na terapia fotodinâmica. Esses tubos foram irradiados com doses de 5 a 20 Gy. A solução Fricke convencional também foi irradiada com as mesmas doses. As concentrações de íons férricos nas soluções Fricke convencional e dopadas irradiadas foram medidas num espectrofotômetro com comprimento de onda entre 220 e 340 nm. Os resultados mostraram que quando comparado o Fricke convencional com o Fricke dopado irradiado, as amostras dopadas demonstraram um aumento na resposta da dose absorvida que é proporcional a concentração do Photogem® na solução Fricke. Concluímos que esse procedimento pode ser utilizado para propósitos de dosimetria na terapia com radiossensibilizadores

    Recomendações para se evitar grandes erros de dose em tratamentos radioterapêuticos Recommendations to avoid gross errors of dose in radiotherapeutic treatments

    No full text
    Erros humanos são uma importante fonte de falhas em todos os passos do planejamento e do tratamento radioterapêutico. Com o objetivo de reduzir este grau de incerteza, várias organizações especializadas recomendam minuciosos programas de garantia da qualidade. No Brasil, programas deste tipo vêm tendo sua exigência intensificada, e a maioria dos serviços de radioterapia vem se orientando neste sentido, tanto em relação aos equipamentos de radiação e dosimetria, quanto em relação à verificação dos cálculos de dose em pacientes e das revisões das fichas de planejamento. Como uma contribuição a este esforço de qualidade, apresentam-se algumas recomendações para se evitar falhas de tratamento devidas a erros na dose de radiação recebida pelo paciente, como redundância nas verificações dos cálculos feitos manualmente ou por computador, e, também, a verificação da dose acumulada para cada paciente sob tratamento, semanalmente, além de se evitar a possibilidade de acesso a qualquer sistema de segurança do equipamento ao pessoal técnico treinado para apenas o operar. Além disso, deve-se considerar a possibilidade de se empregar um sistema computadorizado de verificação e registro do tratamento, dessa maneira prevenindo-se erros durante a aplicação diária devidos à seleção indevida dos diferentes parâmetros do tratamento. Reportam-se quatro incidentes radioativos recentes ocorridos no mundo, com injúrias em pacientes, e algumas ocorrências de erros grandes de dose.<br>Human mistakes are an important source of errors in radiotherapy and may occur at every step of the radiotherapeutic planning and treatment. To reduce this level of uncertainties, several specialized organizations have recommended a comprehensive quality assurance program. In Brazil, the requirement for these programs has been strongly stressed, and most radiotherapy services have pursued this goal regarding radiation units and dosimetry equipment, as well as the verification of the calculations of the patient's dose and the revision of the plan charts. As a contribution to the improvement of quality control, we present some recommendations to avoid failure of treatment due to error in the delivered dose, such as redundant check of the manual or computer calculations, weekly check of the total dose for each patient, and prevention of inadvertent access to any safety system of the equipment by any staff member that is only supposed to operate the machine. Moreover, the use of a computerized treatment record and verification system should be considered in order to eliminate errors due to incorrect selection of the treatment parameters, in a daily basis. We report four radioactive incidents with patient injuries occurred throughout the world and some gross errors of dose

    Terapia fotodinâmica com ftalocianina de zinco tópica: avaliação da intensidade de fluorescência, absorção cutânea, alterações histológicas e imuno-histoquímicas na pele do modelo animal Topical photodynamic therapy with zinc phthalocyanine: evaluation of fluorescence intensity, skin absorption, skin histological and immunohistochemical changes in animal model

    No full text
    FUNDAMENTOS - Ftalocianinas são promissores agentes fotossensibilizadores na terapia fotodinâmica (TFD). OBJETIVOS - Avaliar intervalos, veículos e a incorporação de promotor de absorção na formulação tópica da ftalocianina de zinco (FC-Zn). Avaliar alterações macro e micromorfológicas e a expressão de Fas promovidas pela TFD com FC-Zn tópica no modelo murino. MÉTODOS - Por meio da espectrometria de fluorescência, foram avaliadas combinações de diferentes períodos de oclusão tópica das formulações gel ou emulsão de FC-Zn (1mg/dl), com ou sem monoleína 5%, no dorso do camundongo hairless. Após oito horas das diferentes formulações, os camundongos foram expostos ao laser de diodo de 670nm, dose de 50J/cm-². RESULTADOS - A fluorescência foi discretamente superior após oito horas e com a emulsão nos intervalos de uma, duas e quatro horas de oclusão. A intensidade do edema e da erosão correspondeu à necrose da epiderme e à imunoexpressão de Fas nos cortes histológicos de pele. CONCLUSÕES - Os achados indicam a ação fotodinâmica promovida pela interação entre FC-Zn e fonte de luz de 670nm. As alterações macro e micromorfológicas foram correspondentes e mais substanciais com a emulsão FC-Zn e monoleína, sugerindo a acentuação dos efeitos com essa formulação. A imunoexpressão de Fas e as alterações histológicas sugeriram a apoptose como mecanismo de morte celular na TFD com FC-Zn tópica.<br>BACKGROUND - Phthalocyanines are promising photosensitizers used in photodynamic therapy (PDT). OBJECTIVES - To evaluate the following parameters: intervals, vehicles and enhancer using topical zinc-phthalocyanine (Zn-PC) formulation. To examine macro and micromorphological changes and Fas expression induced by topical Zn-PC-PDT on murine skin. MATERIAL AND METHODS - Using fluorescence spectrometry, different intervals of topical occlusion employing Zn-PC gel or emulsion, with or without monolein 5% were studied. After an 8-hour occlusion of different formulations, the mice were exposed to 670 nm laser, at a 50 J.cm-² dose. RESULTS - Fluorescence was slightly higher after 8 hours, and also with emulsion formulation at one-, two- and four-hour occlusion periods. The intensity of edema and erosion were correlated to epidermal necrosis and to Fas immunoexpression in skin histological specimens. CONCLUSIONS - The results show the effects of photodynamic action promoted by the interaction between Zn-PC formulation and a 670-nm light source. Macro and micromorphological alterations were correlated and more substantial with monolein and Zn-PC emulsion, suggesting more marked effects with this formulation. The Fas immunoexpression and histological changes suggested that apoptosis plays a role in the mechanism of cell death caused by PDT based in Zn-PC