4,804 research outputs found
ATLAS physics performance and commissioning
ATLAS, one of the two multi-purpose detectors at the proton-proton collider LHC, is scheduled to start taking data in 2007. This paper presents the physics performance of this experiment in studying one of the main topics of the LHC physics : the Higgs search. The use of the first data for the detector commissioning and the physics measurements that can be done in the early phase of the LHC operation are also reviewed
Uniformity of the 2000 test beam module with the new optimal filtering coefficients
An original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the electrical description of the read-out electronics in the reconstruction of the physics pulses. Results on improvements in the LARG response and in particular on the energy uniformity of the calorimeter are shown
Uniformity Of The 2000 Test Beam Module With The New Optimal Filtering Coefficients
An original method to reconstruct electron and pion signals in the Liquid ARGon barrel calorimeter (LARG) is applied to test beam data collected at the H8 line of the CERN North Area in July and August 2000. The method is based on the use of optimal filtering coefficients and takes into account the electrical description of the read-out electronics in the reconstruction of the physics pulses. Results on improvements in the LARG response and in particular on the energy uniformity of the calorimeter are shown
Independent validation of sepsis index for sepsis screening in the emergency department
(1) Background: The early detection of sepsis is still challenging, and there is an urgent need for biomarkers that could identify patients at a high risk of developing it. We recently developed an index, namely the Sepsis Index (SI), based on the combination of two CBC parameters: monocyte distribution width (MDW) and mean monocyte volume (MMV). In this study, we sought to independently validate the performance of SI as a tool for the early detection of patients at a high risk of sepsis in the Emergency Department (ED). (2) Methods: We enrolled all consecutive patients attending the ED with a request of the CBC. MDW and MMV were measured on samples collected in K3-EDTA tubes on the UniCel DxH 900 haematology analyser. SI was calculated based on the MDW and MMV. (3) Results: We enrolled a total of 703 patients stratified into four subgroups according to the Sepsis-2 criteria: control (498), infection (105), SIRS (52) and sepsis (48). The sepsis subgroup displayed the highest MDW (median 27.5, IQR 24.6–32.9) and SI (median 1.15, IQR 1.05–1.29) values. The ROC curve analysis for the prediction of sepsis showed a good and comparable diagnostic accuracy of the MDW and SI. However, the SI displayed an increased specificity, positive predictive value and positive likelihood ratio in comparison to MDW alone. (4) Conclusions: SI improves the diagnostic accuracy of MDW for sepsis screening
Procalcitonin and community-acquired pneumonia (CAP) in children
The role of procalcitonin (PCT) as a biomarker for sepsis in
adults is well documented, while its role in infections affecting
neonatal children remains controversial. Among these infections,
Community-Acquired pneumonia (CAP) has been studied extensively, because
it's the second cause of death in children in developing countries, and
one of the most frequent causes of hospitalization in industrialized
countries.
The PubMed database and the Cochrane Library were used to search for the
following keywords: CAP, procalcitonin, children. Thirteen articles were
studied to determine the role of PCT in CAP management, specifically its
usefulness for distinguishing pneumococcal infections from viral and
unknown infections, for predicting severity and the correct antibiotic
treatment. This paper focuses on the studies performed to identify the
best inflammatory biomarker for CAP management.
Although there is an increase in studies confirming the usefulness of PCT
in CAP management in children, further studies are needed to have better
understanding of its role for pediatric CAP management
Evaluation of anti-sars-cov-2 s-rbd igg antibodies after covid-19 mrna bnt162b2 vaccine
(1) Background: The evaluation of anti-spike protein receptor-binding domain (S-RBD) antibodies represents a useful tool to estimate the individual protection against Severe Acute Respiratory Syndrome CoronaVirus 2 (SARS-CoV-2) infection; (2) Methods: We evaluated anti S-RBD IgG levels by indirect chemiluminescence immunoassay on Maglumi 800 (SNIBE, California) in 2248 vaccinated subjects without previous SARS-CoV-2 infection, 91 vaccinated individuals recovered from COVID-19, and 268 individuals recovered from COVID-19 who had not been vaccinated. Among those who were healthy and vaccinated, 352 subjects performed a re-dosing after about 72 days from the first measurement. (3) Results: Anti S-RBD IgG levels were lower in subjects with previous infection than vaccinated subjects, with or without previous infection (p < 0.001). No difference was observed between vaccinated subjects, with and without previous SARS-CoV-2 infection. Overall, anti-RBD IgG levels were higher in females than males (2110 vs. 1341 BAU/mL; p < 0.001) as well as in subjects with symptoms after vaccination than asymptomatic ones (2085 vs. 1332 BAU/mL; p = 0.001) and lower in older than younger subjects. Finally, a significant decrease in anti-RBD IgG levels was observed within a short period from a complete two-dose cycle vaccination. (4) Conclusions: Our results show an efficacy antibody response after vaccination with age-, timeand sex-related differences
The Met80Ala and Tyr67His/Met80Ala mutants of human cytochrome cshed light on the reciprocal role of Met80 and Tyr67 in regulating ligand access into the heme pocket.
The spectroscopic and functional properties of the single Met80Ala and double Tyr67His/Met80Ala mutants of human cytochrome c have been investigated in their ferric and ferrous forms, and in the presence of different ligands, in order to clarify the reciprocal effect of these two residues in regulating the access of exogenous molecules into the heme pocket. In the ferric state, both mutants display an aquo high spin and a low spin species. The latter corresponds to an OH- ligand in Met80Ala but to a His in the double mutant. The existence of these two species is also reflected in the functional behavior of the mutants. The observation that (i) a significant peroxidase activity is present in the Met80Ala mutants, (ii) the substitution of the Tyr67 by His leads to only a slight increase of the peroxidase activity in the Tyr67His/Met80Ala double mutant with respect to wild type, while the Tyr67His mutant behaves as wild type, as previously reported, suggests that the peroxidase activity of cytochrome c is linked to an overall conformational change of the heme pocket and not only to the disappearance of the Fe-Met80 bond. Therefore, in human cytochrome c there is an interplay between the two residues at positions 67 and 80 that affects the conformation of the distal side of the heme pocket, and thus the sixth coordination of the hem
Emerging cross-disciplinary profiles: The Geomatic Epidemiologist
Abstract
Issue
Geographic information systems (GIS) and remote sensing technologies are increasingly used in Public Health epidemiology, showing a great potential in anticipating and responding to actual and future challenges for the public health system and in improving health services' excellence. According to the evidences collected within a wide meta-research carried on of relevant literature ("GIS geographic information system" and "GIS geographic information system and training" on Pubmed; "epidemiologist use of GIS and training" and "epidemiologist use of gis" on Google Scholar),GIS and new sensing technologies are mostly used to: map air and water pollution, map diseases prevalence, predict infection diseases and vector-spread diseases in big areas, study health service coverage and preparedness in emergencies, map cities and study urban health, study climate changes for decision making.
Description of the Problem
Specific skills and training are required to address the use of GIS and new sensing technologies.The specific aim of our study is to identify the professional profile of a new figure, called 'Geomatic Epidemiologist' and to define its professional and educational standards, as well as the relevant training programs.
Results
Data collection and analysis of INAPP and ESCO databases about existing professional profiles (starting from 2016) has allowed drafting a first qualification schema and profile. The profile has been defined according to the 4C model (elaborated by Univaq) distinguishing between Hard Skills (technical knowledge and skills),Soft Skills (cognitive, individual and social) and interpersonal behaviors.
Conclusions
Profile will be validated with relevant stakeholders and Public Health professionals in order to deepen the understanding of the main competences required to study health issues with GIS and related technologies; to this extent, a questionnaire has been elaborated to evaluate relevance, frequency and complexity of each component of the profile
Key messages
Developing cross-disciplinary profiles, (i.e. the Geomatic Epidemiologist) integrating clusters of competences (holistic approach). Public health research challenges and excellence
A new tool for sepsis screening in the Emergency Department
In this study, we developed and evaluated the diagnostic accuracy of the Sepsis Index for early sepsis screening in the Emergency Department (ED). Sepsis Index is based on the combination of monocyte distribution width (MDW) and mean monocyte volume (MMV). Sepsis Index≥1 was selected to define sepsis. We tested its diagnostic accuracy in an ED population stratified in four groups: Controls, Systemic Inflammatory Response Syndrome (SIRS), infection, and sepsis, according to Sepsis-2 criteria. Patients with sepsis displayed higher median Sepsis Index value than patients without sepsis. At the receiver operating characterictis (ROC) curve analysis for the prediction of sepsis, the area under the curve (AUC) of MDW and Sepsis Index were similar: 0.966 (95%CI 0.947-0.984), and 0.964 (95%CI 0.942-0.985), respectively. Sepsis Index showed increased specificity than MDW (94.7 vs. 90.6%), without any decrease in sensitivity (92.0%). Additionally, LR+ increased from 9.8 (MDW) to 17.4 (Sepsis Index), without any substantial change in LR-(respectively 0.09 vs. 0.08). Finally, PPV increased from 0.286 (MDW) to 0.420 (Sepsis Index). Sepsis Index improves the diagnostic accuracy of MDW alone for sepsis screening
Optimization of RPCs read-out panel with electromagnetic simulation
With the upgrade of the RPCs [1]-[2] and the increase of its performances,
the study and the optimization of the read-out panel is necessary in order to
maintain the signal integrity and to reduce the intrinsic crosstalk. Through
Electromagnetic Simulation, performed with CST Studio Suite, new panels design
are tested and their crosstalk property are studied. The behavior of different
type of panel is shown, in particular a panel with the decoupling strip
connected through their characteristic impedance to the ground plane is
simulated
- …