27 research outputs found
Recommended from our members
Observations of the morning development of the urban boundary layer over London, UK, taken during the ACTUAL project
The study of the boundary layer can be most difficult when it is in transition and forced by a complex surface, such as an urban area. Here, a novel combination of ground-based remote sensing and in situ instrumentation in central London, UK, is deployed, aiming to capture the full evolution of the urban boundary layer (UBL) from night-time until the fully-developed convective phase. In contrast with the night-time stable boundary layer observed over rural areas, the night-time UBL is weakly convective. Therefore, a new approach for the detection of the morning-transition and rapid-growth phases is introduced, based on the sharp, quasi-linear increase of the mixing height. The urban morning-transition phase varied in duration between 0.5 and 4 h and the growth rate of the mixing layer during the rapid-growth phase had a strong positive relationship with the convective velocity scale, and a weaker, negative relationship with wind speed. Wind shear was found to be higher during the night-time and morning-transition phases than the rapid-growth phase and the shear production of turbulent kinetic energy near the mixing-layer top was around six times larger than surface shear production in summer, and around 1.5 times larger in winter. In summer under low winds, low-level jets dominated the UBL, and shear production was greater than buoyant production during the night-time and the morning-transition phase near the mixing-layer top. Within the rapid-growth phase, buoyant production dominated at the surface, but shear production dominated in the upper half of the UBL. These results imply that regional flows such as low-level jets play an important role alongside surface forcing in determining UBL structure and growth
Recommended from our members
A sodar for profiling in a spatially inhomogeneous urban environment
The urban boundary layer, above the canopy, is still poorly understood. One of the challenges is obtaining data by sampling more than a few meters above the rooftops, given the spatial and temporal inhomogeneities in both horizontal and vertical. Sodars are generally useful tools for ground-based remote sensing of winds and turbulence, but rely on horizontal homogeneity (as do lidars) in building up 3-component wind vectors from sampling three or more spatially separated volumes. The time taken for sound to travel to a typical range of 200âm and back is also a limitation. A sodar of radically different design is investigated, aimed at addressing these problems. It has a single vertical transmitted sound pulse. Doppler shifted signals are received from a number of volumes around the periphery of the transmitted beam with microphones which each having tight angular sensitivity at zenith angles slightly off-vertical. The spatial spread of sampled volumes is therefore smaller. By having more receiver microphones than a conventional sodar, the effect of smaller zenith angle is offset. More rapid profiling is also possible with a single vertical transmitted beam, instead of the usual multiple beams.A prototype design is described, together with initial field measurements. It is found that the beam forming using a single dish antenna and the drift of the sound pulse downwind both give rise to reduced performance compared with expectations. It is concluded that, while the new sodar works in principle, the compromises arising in the design mean that the expected advantages have not been realize
Recommended from our members
Observations of urban boundary layer structure during a strong urban heat island event
It has long been known that the urban surface energy balance is different to that of a rural surface, and that heating of the urban surface after sunset gives rise to the Urban Heat Island (UHI). Less well known is how flow and turbulence structure above the urban surface are changed during different phases of the urban boundary layer (UBL). This paper presents new observations above both an urban and rural surface and investigates how much UBL structure deviates from classical behaviour. A 5-day, low wind, cloudless, high pressure period over London, UK, was chosen for analysis, during which there was a strong UHI. Boundary layer evolution for both sites was determined by the diurnal cycle in sensible heat flux, with an extended decay period of approximately 4 h for the convective UBL. This is referred to as the âUrban Convective Islandâ as the surrounding rural area was already stable at this time. Mixing height magnitude depended on the combination of regional temperature profiles and surface temperature. Given the daytime UHI intensity of 1.5âC, combined with multiple inversions in the temperature profile, urban and rural mixing heights underwent opposite trends over the period, resulting in a factor of three height difference by the fifth day. Nocturnal jets undergoing inertial oscillations were observed aloft in the urban wind profile as soon as the rural boundary layer became stable: clear jet maxima over the urban surface only emerged once the UBL had become stable. This was due to mixing during the Urban Convective Island reducing shear. Analysis of turbulent moments (variance, skewness and kurtosis) showed âupside-downâ boundary layer characteristics on some mornings during initial rapid growth of the convective UBL. During the âUrban Convective Islandâ phase, turbulence structure still resembled a classical convective boundary layer but with some influence from shear aloft, depending on jet strength. These results demonstrate that appropriate choice of Doppler lidar scan patterns can give detailed profiles of UBL flow. Insights drawn from the observations have implications for accuracy of boundary conditions when simulating urban flow and dispersion, as the UBL is clearly the result of processes driven not only by local surface conditions but also regional atmospheric structure
30 minute averaged overview data from the Silsoe Refresh Cube Campaign (RCC)
All 30 minute averaged data taken during the Refresh Cube Campaign (RCC) at Silsoe using the 6 m^3 test structure at the site and eight other 6 m^3 straw cubes undertaken as part of the PhD work of Gough (2017) and forms the full-scale experiments of the REFRESH project.
The data-set is split into two sections: an isolated cube and the array case with three different opening set-ups being undertaken for both array and isolated.
The array was in place October 2014 to April 2015, and the cube was isolated from May 2015 to July 2015.
Details of the experimental set-ups are available in publications.
The data contained within this document are 30 minute averaged and quality controlled using code previously used for the ACTUAL project.
The data set contains wind speeds, wind directions, internal and external temperatures, surface pressures, CO_2 concentrations and ventilation rates calculated from the pressure difference methods. Internal and external measurements are included for the flow
Recommended from our members
Ground-based aerosol optical depth trends at three high-altitude sites in Switzerland and Southern Germany from 1995â2010
Ground-based aerosol optical depth (AOD) climatologies at three high-altitude sites in Switzerland (Jungfraujoch and Davos) and Southern Germany (Hohenpeissenberg) are updated and re-calibrated for the period 1995 â 2010. In addition, AOD time-series are augmented with previously unreported data, and are homogenized for the first time. Trend analysis revealed weak AOD trends (λ = 500 nm) at Jungfraujoch (JFJ; +0.007 decade-1), Davos (DAV; +0.002 decade-1) and Hohenpeissenberg
(HPB; -0.011 decade-1) where the JFJ and HPB trends were statistically significant at the 95% and 90% confidence levels. However, a linear trend for the JFJ 1995 â 2005 period was found to be more appropriate than for 1995 â 2010 due to the influence of stratospheric AOD which gave a trend -0.003 decade-1 (significant at 95% level). When correcting for a recently available stratospheric AOD time-series, accounting for Pinatubo (1991) and more recent volcanic eruptions, the
1995 â 2010 AOD trends decreased slightly at DAV and HPB but remained weak at +0.000 decade-1 and -0.013 decade-1 (significant at 95% level). The JFJ 1995 â 2005 AOD time-series similarly decreased to -0.003 decade-1 (significant at 95% level). We conclude that despite a more detailed re40
analysis of these three time-series, which have been extended by five years to the end of 2010, a significant decrease in AOD at these three high-altitude sites has still not been observed
Recommended from our members
Concept and methodology of characterising infrared radiative performance of urban trees using tree crown spectroscopy
Urban trees play an important role in cooling urban microclimates and regulating outdoor thermal comfort. To better understand their contribution to these processes, it is crucial to elucidate urban treesâ radiative thermal performance, especially in the infrared (IR) region (approximately 50% of solar radiation). Yet, owing to significant conceptual and methodological challenges, studies on the radiative performance of trees have mainly focused on individual leaves rather than crown-level characteristics. Here we applied a novel conceptual and methodological framework to characterise the crown-level IR radiative performance of 10 lime trees (Tilia cordata), a common urban tree in the UK and Europe. Our results show that reflected and transmitted solar energy from leaves is dominated (>70%) by IR radiation. At the leaf level, transmission and reflection spectra are similar between trees (differences typically 40% in IR region) were found between trees. These variations were largely due to crown structural differences (leaf number, density, angles), rather than leaf solar interaction character (leaf-level transmittance or reflectance, leaf colour). Crown transflectance measured from the four cardinal directions was significantly different in the IR region (maximum differences circa 30%), and changed substantially with solar time. Hence, a treeâs surroundings received very different, and time dependent, levels of solar IR radiation. These findings have significant implications for species selection and control of environmental stress factors in urban microclimates
Recommended from our members
Spatial and temporal variability of urban fluxes of methane, carbon monoxide and carbon dioxide above London, UK
We report on more than 3 years of measurements of fluxes of methane (CH4), carbon monoxide (CO) and carbon dioxide (CO2) taken by eddy-covariance in central London, UK. Mean annual emissions of CO2 in the period 2012â2014 (39.1 ± 2.4 ktons kmâ2 yrâ1) and CO (89 ± 16 tons kmâ2 yrâ1 ) were consistent (within 1 and 5% respectively) with values from the London Atmospheric Emissions Inventory, but measured CH4 emissions (72 ± 3 tons kmâ2 yrâ1) were over two-fold larger than the inventory value. Seasonal variability was large for CO with a winter to summer reduction of 69 %, and monthly fluxes were strongly anti-correlated with mean air temperature. The winter increment in CO emissions was attributed mainly to vehicle cold starts and reduced fuel combustion efficiency. CO2 fluxes were 33 % higher in winter than in summer and anti-correlated with mean air temperature, albeit to a lesser extent than for CO. This was attributed to an increased demand for natural gas for heating during the winter. CH4 fluxes exhibited moderate seasonality (21 % larger in winter), and a spatially variable linear anti-correlation with air temperature. Differences in resident population within the flux footprint explained up to 90 % of the spatial variability of the annual CO2 fluxes and up to 99 % for CH4. Furthermore, we suggest that biogenic sources of CH4, such as wastewater, which is unaccounted for by the atmospheric emissions inventories, make a substantial contribution to the overall bud- get and that commuting dynamics in and out of central business districts could explain some of the spatial and temporal variability of CO2 and CH4 emissions. To our knowledge,this study is unique given the length of the data sets presented, especially for CO and CH4 fluxes. This study offers an independent assessment of âbottom-upâ emissions inventories and demonstrates that the urban sources of CO and CO2 are well characterized in London. This is however not the case for CH4 emissions which are heavily underestimated by the inventory approach. Our results and others point to opportunities in the UK and abroad to identify and quantify the âmissingâ sources of urban methane, revise the methodologies of the emission inventories and devise emission reduction strategies for this potent greenhouse gas
Recommended from our members
Effects of variability of local winds on cross ventilation for a simplified building within a full-scale asymmetric array: overview of the Silsoe field campaign
The large body of natural ventilation research, rarely addresses the effects of the urban area on ventilation rates. A novel contribution to this gap is made by the REFRESH cube campaign (RCC). During 9 months of observations, the Silsoe cube was both isolated and surrounded by a limited asymmetrical staggered array. A wide range of variables were measured continuously, including: local, reference and internal flow, stability, background meteorological conditions, internal temperature, and ventilation rates (pressure difference techniques for cross ventilated cases). This paper tests the impact of the array on the relation between local and reference wind speeds as modified by wind direction and on cross ventilation rates. The presence of the array causes a 50% to 90% reduction in normalised ventilation rate when the reference wind direction is normal to the cube. The decrease in natural ventilation varies with wind direction with large amounts of scatter for both setups. The relation between local and reference wind speeds for the array case had two characteristic responses, not explained by reference wind (speed or direction) nor sensitive to averaging period, turbulence intensity or temperature differences. Given the singular response of the CIBSE approach, it is unable to capture these conditions
Recommended from our members
Field measurement of natural ventilation rate in an idealised full-scale building located in a staggered urban array: comparison between tracer gas and pressure-based methods
Currently, no clear standards exist for determining urban building natural ventilation rates, especially under varying realistic meteorological conditions. In this study, ventilation rates are determined using tracer gas decay and pressure-based measurements for a full-scale (6 m tall) cube. The cube was either isolated (2 months of observations) or sheltered within a staggered array (7 months), for both single-sided and cross ventilation (openings 0.4 x 1 m). Wind speeds at cube height ranged between 0.04 m s-1 and 13.1 m s-1. Errors for both ventilation methods are carefully assessed. There is no discernible linear relation between normalised ventilation rates from the two methods, except for cross ventilation in the array case. The ratio of tracer gas and pressure derived ventilation rates is assessed with wind direction. For single-sided (leeward opening) cases it approached 1. For cross ventilation the ratio was closer to 1 but with more scatter. One explanation is that agreement is better when internal mixing is less jet-dominated, i.e. for oblique directions in the isolated case and for all directions for unsteady array flows. Sheltering may reduce the flushing rate of the tracer gas from the cube relative to internal mixing rate. This new dataset provides an extensive range of conditions for numerical model evaluation and for understanding uncertainty of ventilation rates. Knowledge of the latter is critical in buildin