7 research outputs found

    Current Status and Future Challenges for Teacher Training for ESD

    Get PDF
    STEM micrographs of 99% <sup>13</sup>C graphene imaged with electrons accelerated by a voltage of 100 kV. Each item in the fileset is a ZIP archive containing a single time series of consecutive frames recorded with a medium angle annular dark field detector until an ejection was observed

    12C graphene, 85 kV

    No full text
    STEM micrographs of 99% <sup>12</sup>C graphene imaged with electrons accelerated by a voltage of 85 kV. Each item in the fileset is a ZIP archive containing a single time series of consecutive frames recorded with a medium angle annular dark field detector until an ejection was observed.<br

    12C graphene, 95 kV

    No full text
    STEM micrographs of 99% <sup>12</sup>C graphene imaged with electrons accelerated by a voltage of 95 kV. Each item in the fileset is a ZIP archive containing a single time series of consecutive frames recorded with a medium angle annular dark field detector until an ejection was observed.<br

    12C graphene, 100 kV

    No full text
    STEM micrographs of 99% <sup>12</sup>C graphene imaged with electrons accelerated by a voltage of 100 kV. Each item in the fileset is a ZIP archive containing a single time series of consecutive frames recorded with a medium angle annular dark field detector until an ejection was observed.<br

    13C graphene, 90 kV

    No full text
    STEM micrographs of 99% <sup>13</sup>C graphene imaged with electrons accelerated by a voltage of 90 kV. Each item in the fileset is a ZIP archive containing a single time series of consecutive frames recorded with a medium angle annular dark field detector until an ejection was observed

    12C graphene, 90 kV

    No full text
    STEM micrographs of 99% <sup>12</sup>C graphene imaged with electrons accelerated by a voltage of 90 kV. Each item in the fileset is a ZIP archive containing a single time series of consecutive frames recorded with a medium angle annular dark field detector until an ejection was observed.<br

    Additional file 1: of Variation in haemodynamic monitoring for major surgery in European nations: secondary analysis of the EuSOS dataset

    No full text
    Supplemental digital content. Patient flow diagram (supplementary Figure 1), variation in the use of different types of cardiac output monitoring in European nations (supplementary Figure 2) and types of haemodynamic monitoring used in European nations (supplementary Table). (PDF 333 kb
    corecore