46 research outputs found

    Numerical simulation of strain-adaptive bone remodelling in the ankle joint

    Get PDF
    Background: The use of artificial endoprostheses has become a routine procedure for knee and hip joints while ankle arthritis has traditionally been treated by means of arthrodesis. Due to its advantages, the implantation of endoprostheses is constantly increasing. While finite element analyses (FEA) of strain-adaptive bone remodelling have been carried out for the hip joint in previous studies, to our knowledge there are no investigations that have considered remodelling processes of the ankle joint. In order to evaluate and optimise new generation implants of the ankle joint, as well as to gain additional knowledge regarding the biomechanics, strain-adaptive bone remodelling has been calculated separately for the tibia and the talus after providing them with an implant. Methods: FE models of the bone-implant assembly for both the tibia and the talus have been developed. Bone characteristics such as the density distribution have been applied corresponding to CT scans. A force of 5,200 N, which corresponds to the compression force during normal walking of a person with a weight of 100 kg according to Stauffer et al., has been used in the simulation. The bone adaptation law, previously developed by our research team, has been used for the calculation of the remodelling processes. Results: A total bone mass loss of 2% in the tibia and 13% in the talus was calculated. The greater decline of density in the talus is due to its smaller size compared to the relatively large implant dimensions causing remodelling processes in the whole bone tissue. In the tibia, bone remodelling processes are only calculated in areas adjacent to the implant. Thus, a smaller bone mass loss than in the talus can be expected. There is a high agreement between the simulation results in the distal tibia and the literature regarding. Conclusions: In this study, strain-adaptive bone remodelling processes are simulated using the FE method. The results contribute to a better understanding of the biomechanical behaviour of the ankle joint and hence are useful for the optimisation of the implant geometry in the future

    Comparison between simulation results and DEXA investigation of the bone remodelling after implanting a cementless long stem hip prosthesis

    Get PDF
    Bone remodelling around a femoral prosthesis is one of the main reasons of aseptic loosening of the implant’s stem. The difference in stiffness between the bone tissue and the prosthesis leads to unload the periprosthetic bone and thus to decrease the bone mineral density (BMD), which is known as stress shielding. This paper represents a comparison between measured changes in (BMD) in a periprosthetic Femur with a cementless Bicontact stem by prospective dualenergy X-ray absorptiometry study (DEXA)and calculated changes of the (BMD) using a finite element method (FEM). As a result, it is determined that the total deviation between the two investigations is about 18%.DF

    Patient-individual hip cups: simulation-based design and sheet metal forming manufacturing

    Get PDF
    The revision of an hip prosthesis can have different reasons. One frequent cause, especialley after implantation of a conventional cup, is the so called stress-shielding effect which can lead to a migration or loosening. Patientspecific hip cups can be used to counteract this. However, individual hip cups are only implanted for the treatment of great deformations or tumours because of the cost-intensive manufacturing. Within this project a patient-specific hip cup prosthesis has to be developed and manufactured. Besides the numerical design by means of a coupling between multi-body simulation (MBS) and finite element method (FEM), an inovative concept for the production of patientindividual hip prosthesis out of titanium sheets is introduced in this study.DF

    Dynamic in vitro measurement of patellar movement after total knee arthroplasty: an in vitro study

    Get PDF
    BACKGROUND: Changing the kinematic behaviour of patellar movement could be one of the reasons for anterior knee pain after implantation of a total knee arthroplasty (TKA). The aim of the current study was to measure the potential influence on patellar kinematics of patellar resurfacing during TKA. METHODS: Patellar movement before and after TKA with and without patellar resurfacing was measured under dynamic conditions in an in vitro cadaver simulation. Physiologic Musculus quadriceps forces were applied to five physiologic human knee specimens undergoing simulated isokinetic extension motions, patellar movement was measured using an ultrasonic measurement system. Thereafter, the Interax(® )I.S.A.-prosthesis system was implanted without and with resurfacing the patella, and patellar movement was again measured. RESULTS: The physiologic patella center moved on a semilunar path up to 6.4 mm (SD 6.4 mm) medially during extension. After TKA, the unresurfaced patella showed significantly less medial translation (p = 0.04) than the resurfaced patella. Subsequent resurfacing of the patella then resulted in a return to mediolateral positioning of the patella similar to the physiological case, whereas the resurfaced patella tilted up to twice as much as physiologic. CONCLUSION: The results of this study suggest that resurfacing of the patella during TKA can result in a restoration of the physiologic mediolateral shift of the patellofemoral joint while angulation of the patella remains unphysiologic

    The effect of functional splinting on mild dysplastic hips after walking onset

    Get PDF
    BACKGROUND: For treatment of Graf class IIb dysplastic hips at walking onset a treatment concept with abduction splints allowing patterns as walking and crawling under constant abduction control was investigated. However, as the splint still incapacitates child movements the research question remains whether the physiologically progressing maturation of hips can be significantly altered using such abduction splints for walking children. METHODS: Of 106 children showing late hip dysplasia, 68 children treated with the Hoffman-Daimler (HD-splint) abduction splint were compared with 38 children with neglect of the abduction treatment in this retrospective study. Radiographic analyses were performed measuring the development of the age dependent acetabular angle. RESULTS: The regression analysis for splint treatment showed a significant linear regression for both splint treatment and no splint treatment group (r(2 )= 0,31 respectively r(2 )= 0,33). No statistical difference between both treatment groups was apparent. CONCLUSION: Considering the characteristics of this study, there seems to be no strong rationale supporting the use of an abduction device in growing children. As no significant difference between treatment groups is apparent, a future controlled prospective study on splinting effects can be considered ethically allowed

    Dynamische In-vitro-Druck- und Bewegungsmessung des LCS-Prothesensystems.

    No full text

    Dynamic in vitro measurement of patellar movement after total knee arthroplasty: an in vitro study

    No full text
    Abstract Background Changing the kinematic behaviour of patellar movement could be one of the reasons for anterior knee pain after implantation of a total knee arthroplasty (TKA). The aim of the current study was to measure the potential influence on patellar kinematics of patellar resurfacing during TKA. Methods Patellar movement before and after TKA with and without patellar resurfacing was measured under dynamic conditions in an in vitro cadaver simulation. Physiologic Musculus quadriceps forces were applied to five physiologic human knee specimens undergoing simulated isokinetic extension motions, patellar movement was measured using an ultrasonic measurement system. Thereafter, the Interax® I.S.A.-prosthesis system was implanted without and with resurfacing the patella, and patellar movement was again measured. Results The physiologic patella center moved on a semilunar path up to 6.4 mm (SD 6.4 mm) medially during extension. After TKA, the unresurfaced patella showed significantly less medial translation (p = 0.04) than the resurfaced patella. Subsequent resurfacing of the patella then resulted in a return to mediolateral positioning of the patella similar to the physiological case, whereas the resurfaced patella tilted up to twice as much as physiologic. Conclusion The results of this study suggest that resurfacing of the patella during TKA can result in a restoration of the physiologic mediolateral shift of the patellofemoral joint while angulation of the patella remains unphysiologic.</p