    Colorimetric Phosphate Detection Using Organic DFB Laser Based Absorption Spectroscopy

    No full text
    A novel compact laser absorption spectrometer is developed for colorimetric detection. We demonstrate the realization of the system as well as example measurements of phosphate in water samples based on the malachite green (MG) method. A phosphate concentration range of 1 mg/L to 31.25 μg/L (which corresponds to a molar concentration range of 10.5 μmol/L to 329 nmol/L) is investigated. This photometer demonstrates the ease of integration of organic distributed feedback (DFB) lasers and their miniaturizability, leading the way toward optofluidic on-chip absorption spectrometers. We constructed an optically pumped organic second-order DFB laser on a transparent substrate, including a transparent encapsulation layer, to have access to both emission directions of the surface-emitting laser. Using the two different surface emission directions of the laser resonator allows monitoring of the emitted light intensity without using additional optical elements. Based on these advances, it is possible to miniaturize the measurement setup of a laser absorption spectrometer and to measure analytes, such as phosphate

    Water jacket systems for temperature control of Petri dish cell culture chambers

    No full text
    Water jacket systems are routinely used to control the temperature of Petri dish cell culture chambers. Despite their widespread use, the thermal characteristics of such systems have not been fully investigated. In this study, we conducted a comprehensive set of theoretical, numerical and experimental analyses to investigate the thermal characteristics of Petri dish chambers under stable and transient conditions. In particular, we investigated the temperature gradient along the radial axis of the Petri dish under stable conditions, and the transition period under transient conditions. Our studies indicate a radial temperature gradient of 3.3 °C along with a transition period of 27.5 min when increasing the sample temperature from 37 to 45 °C for a standard 35 mm diameter Petri dish. We characterized the temperature gradient and transition period under various operational, geometric, and environmental conditions. Under stable conditions, reducing the diameter of the Petri dish and incorporating a heater underneath the Petri dish can effectively reduce the temperature gradient across the sample. In comparison, under transient conditions, reducing the diameter of the Petri dish, reducing sample volume, and using glass Petri dish chambers can reduce the transition period
    corecore