68 research outputs found

    Minimalist's Linux Cluster

    Full text link
    Using barebone PC components and NIC's, we construct a linux cluster which has 2-dimensional mesh structure. This cluster has smaller footprint, is less expensive, and use less power compared to conventional linux cluster. Here, we report our experience in building such a machine and discuss our current lattice project on the machine.Comment: 3 pages, 2 figures, Proceedings of the Lattice 03 Conference (Tsukuba, Japan

    Evaluation of persistent-mode operation in a superconducting MgB2 coil in solid nitrogen

    Get PDF
    We report the fabrication of a magnesium diboride (MgB2) coil and evaluate its persistent-mode operation in a system cooled by a cryocooler with solid nitrogen (SN2) as a cooling medium. The main purpose of SN2 was to increase enthalpy of the cold mass. For this work, an in situ processed carbon-doped MgB2 wire was used. The coil was wound on a stainless steel former in a single layer (22 turns), with an inner diameter of 109 mm and height of 20 mm without any insulation. The two ends of the coil were then joined to make a persistent-current switch to obtain the persistent-current mode. After a heat treatment, the whole coil was installed in the SN2 chamber. During operation, the resultant total circuit resistance was estimated to be \u3c7.4x10−14 Ω at 19.5 K±1.5 K, which meets the technical requirement for magnetic resonance imaging application

    Effect of FIXed-dose combination of ARb and statin on adherence and risk factor control: The randomized FIXAR study

    Get PDF
    Background: The efficacy of fixed-dose combinations (FDCs) in improving adherence and risk factor control for cardiovascular disease has not been reported consistently. Here, we compared adherence and efficacy between an olmesartan/rosuvastatin FDC and the usual regimen. Methods: In this 6-month, open-label, randomized, active-control study, we screened 154 patients; of these, 150 were randomly assigned to receive either olmesartan/rosuvastatin FDC or the usual regimen with separate angiotensin receptor blockers and statins. In total, 135 patients completed the study (median age: 68 years; male: 68.9%). The primary outcome was patients’ adherence; the secondary outcomes were changes in blood pressure (BP) and lipid parameters. Results: During follow-up, adherence in both groups was high and similar between the groups (98.9% and 98.3% in the FDC and usual regimen groups, respectively, p = 0.328). Changes in systolic (–8 and –5 mmHg, respectively, p = 0.084) and diastolic BP (–5 and –2 mmHg, p = 0.092) did not differ significantly, although they were numerically greater in the FDC group. Changes in low-density lipoprotein cholesterol (LDL-C) were greater in the FDC group (–13 and –4 mg/dL, respectively, p = 0.019), whereas changes in other lipid parameters were similar between the groups. The test drugs were well tolerated, showing no difference in safety between the groups. Conclusions: Patients’ adherence was excellent and similar in the groups, whereas the reduction in the LDL-C level was greater in the FDC group. We provide comprehensive information on the adherence and efficacy of an FDC compared to the usual regimen in Korean patients with high cardiovascular risk

    Representative levels of blood lead, mercury, and urinary cadmium in youth: Korean Environmental Health Survey in Children and Adolescents (KorEHS-C), 2012–2014

    Get PDF
    AbstractBackgroundThis study examined levels of blood lead and mercury, and urinary cadmium, and associated sociodemographic factors in 3–18 year-old Korean children and adolescents.Materials and methodsWe used the nationally representative Korean Environmental Health Survey in Children and Adolescents data for 2012–2014 and identified 2388 children and adolescents aged 3–18 years. The median and 95th percentile exposure biomarker levels with 95% confidence intervals (CIs) were calculated. Multivariate regression analyses were performed on log transformed exposure biomarker levels adjusted for age, sex, area, household income, and father’s education level. The median exposure biomarker levels were compared with data from Germany, the US, and Canada, as well as the levels of Korean children measured at different times.ResultsThe median levels of blood lead and mercury, as well as urinary cadmium were 1.23ÎŒg/dL, 1.80ÎŒg/L, and 0.40ÎŒg/L (95% CIs, 1.21–1.25, 1.77–1.83, and 0.39–0.41, respectively). The blood lead levels were significantly higher in boys and younger children (p<0.0001) and children with less educated fathers (p=0.004) after adjusting for covariates. Urinary cadmium level increased with age (p<0.0001). The median levels of blood mercury and urinary cadmium were much higher in Korean children and adolescents than those in their peers in Germany, the US, and Canada. Blood lead levels tended to decrease with increasing age and divergence between the sexes, particularly in the early teen years. Median levels of blood lead and urinary cadmium decreased since 2010.ConclusionSociodemographic factors, including age, sex, and father’s education level were associated with environmental exposure to heavy metals in Korean children and adolescents. These biomonitoring data are valuable for ongoing surveillance of environmental exposure in this vulnerable population

    Evaluation of a solid nitrogen impregnated MgB2 racetrack coil

    Get PDF
    To develop powerful wind turbine generators using superconducting technology, high-performance superconducting racetrack coils are essential. Herein, we report an evaluation of a multifilamentary magnesium diboride (MgB2) conductor-based racetrack coil cooled and impregnated simultaneously by solid nitrogen (SN2). The coil was wound on a copper former with 13 mm winding width, an inner diameter of 124 mm at the curvature, and 130 mm length of the straight section. An in situ processed S-glass-insulated 36-filament MgB2 wire was wound on the former in two layers with 19.5 turns, and heat treated via the wind and react method without any epoxy resin. The coil was evaluated for critical temperature and transport critical current in the SN2 environment at different temperatures up to 31.3 K in self-field. The coil was able to carry 200 A transport current at 28.8 K in self-field. During coil charging and operation, SN2 effectively acted as an impregnation material. The test results demonstrate the viability to use MgB2 racetrack coil potentially with SN2 impregnation in advanced rotating machine applications

    Safety and Efficacy of the Nit-Occlud&reg; Coil for Percutaneous Closure of Various Sizes of PDA

    No full text
    Most interventionalists use the Amplatzer Duct Occluder (ADO) or the Nit-Occlud&reg; Coils (NOC) to close patent ductus arteriosus (PDA). Data regarding the success and effect of NOCs in the occlusion of large PDAs are insufficient. We aimed to investigate whether the PDA occlusion of large PDAs using NOC is safe and efficient for all ages. This was a retrospective study involving 361 pediatric and adult patients who underwent the transcatheter closure of PDA using NOC over the past 21 years for all PDA sizes and ages. The sizes of PDA were classified as small, moderate, and large. A comparison of the aortic pressure before and after PDA occlusion using NOC showed significant differences in terms of systolic and pulse pressures for all age groups (p &lt; 0.05). The rate of the residual shunts of NOC was 2%, while the rate of complete occlusions of NOC was 98% at 12 months after occlusion regardless of the shape of PDA. The complication rate with PDA occlusion using NOC was 5%. PDA occlusion using NOC is as effective and safe as ADO for the occlusion of PDA of all sizes. Therefore, PDA occlusion using NOC can be a safe and feasible procedure to close various sizes and types of PDA without complications

    The characteristics of Bi-2223/Ag conductor for high field application

    Get PDF
    For the development of high magnetic field application using high temperature superconductor (HTS), Bi-2223/Ag tape is one of the promising materials because of its high current capacity and upper critical field. However, Bi-2223/Ag tape shows very strong anisotropy and significant deterioration of critical current in the magnetic field. To explore the possibility of HTS in high field applications, we evaluated the critical current and index value of Bi-2223/Ag conductor in high magnetic field. The Bi-2223/Ag tape was characterized as a function of increasing and decreasing field. The temperature dependence was also examined lower than 4.2 K. All measurements were carried out with hybrid magnet system up to 30 T and the experimental results are reported

    AC Loss in MgB2 Superconducting Wires at Various Operating Temperatures

    No full text
    We investigate the AC loss behavior in MgB2 wires using numerical calculations based on the finite element analysis (FEM). The governing equation for the system was formulated using a magnetic vector potential and an electric scalar potential, taking into account the non-linear, field dependence of the critical current density (Jc). The model incorporated the results of measurements of the Jc-B of for a real MgB2 wire. For this, we directly measured the Jc-B characteristics according to the external fields as well as various temperatures. A transport current loss analysis was performed on the MgB2 wire for a wide range of transport current values and different temperatures. The magnetization loss was also calculated as a function of the external magnetic field and temperature. For both type of losses, the numerical results were found to be in good agreement with those obtained by theoretical calculations, thus verifying the validity of the model
    • 

    corecore