1,025 research outputs found

    Mechanical Stimulation of the HT7 Acupuncture Point to Reduce Ethanol Self-Administration in Rats

    Get PDF
    Background. Alcoholism, which is a disabling addiction disorder, is a major public health problem worldwide. The present study was designed to determine whether the application of acupuncture at the Shenmen (HT7) point suppresses voluntary alcohol consumption in addicted rats and whether this suppressive effect is potentiated by the administration of naltrexone. Methods. Rats were initially trained to self-administer a sucrose solution by operating a lever. A mechanical acupuncture instrument (MAI) for objective mechanical stimulation was used on rats whose baseline response had been determined. In addition, the effect of HT7 acupuncture on beta-endorphin concentration and ethanol intake via naltrexone were investigated in different groups. Results. We found that ethanol intake and beta-endorphin level in rats being treated with the MAI at the HT7 point reduced significantly. The treatment of naltrexone at high doses reduced the ethanol intake and low-dose injection of naltrexone in conjunction with the MAI also suppressed ethanol intake. Conclusions. The results of the current study indicate that using the MAI at the HT7 point effectively reduces ethanol consumption in rats. Furthermore, the coadministration of the MAI and a low dose of naltrexone can produce some more potent reducing effect of ethanol intake than can acupuncture alone

    Manumycin from a new Streptomyces strain shows antagonistic effect against methicillin-resistant Staphylococcus aureus (MRSA)/vancomycin-resistant enterococci (VRE) strains from Korean Hospitals

    Get PDF
    An antimicrobial compound, highly effective against multidrug-resistant (MDR) bacteria, purified from a Streptomyces strain was identified as manumycin. The minimal inhibitory concentrations (MICs) of manumycin against 8 different strains of methicillin-resistant Staphylococcus aureus (MRSA) were ranged 2 to 32 μg/ml. Similarly, MICs of manumycin against 4 vancomycin-resistant enterococci (VRE) strains were ranged 8 to 32 μg/ml while it remained ineffective against 4 other VRE strains. Compared to vancomycin, manumycin provided slightly weaker activity against MRSA strains but stronger activity against 4 VRE strains. This is the first report of antagonistic effect of manumycin against MDR pathogens.Keywords: Manumycin, methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE)African Journal of Biotechnology Vol. 12(17), pp. 2249-225

    Pancreatic serous cystadenocarcinoma with invasive growth into the colon and spleen

    Get PDF
    Serous cystic neoplasms of the pancreas are almost always benign lesions. However, there are some case reports of malignant serous neoplasms of the pancreas. It is very difficult to distinguish malignant and benign tumors. Indeed, only clinicopathologic findings of locoregional invasion and metastasis represent a malignancy. We report a serous cystadenocarcinoma of the pancreas that was initially considered to be colon cancer. Post-operatively, the tumor was confirmed to be a malignant serous cystic tumor of the pancreas. One year later, the patient remains disease-free

    Evaluating Acupuncture Point and Nonacupuncture Point Stimulation with EEG: A High-Frequency Power Spectrum Analysis

    Get PDF
    To identify physical and sensory responses to acupuncture point stimulation (APS), nonacupuncture point stimulation (NAPS) and no stimulation (NS), changes in the high-frequency power spectrum before and after stimulation were evaluated with electroencephalography (EEG). A total of 37 healthy subjects received APS at the LI4 point, NAPS, or NS with their eyes closed. Background brain waves were measured before, during, and after stimulation using 8 channels. Changes in the power spectra of gamma waves and high beta waves before, during, and after stimulation were comparatively analyzed. After NAPS, absolute high beta power (AHBP), relative high beta power (RHBP), absolute gamma power (AGP), and relative gamma power (RGP) tended to increase in all channels. But no consistent notable changes were found for APS and NS. NAPS is believed to cause temporary reactions to stress, tension, and sensory responses of the human body, while APS responds stably compared to stimulation of other parts of the body

    Role of Amphipathic Helix of a Herpesviral Protein in Membrane Deformation and T Cell Receptor Downregulation

    Get PDF
    Lipid rafts are membrane microdomains that function as platforms for signal transduction and membrane trafficking. Tyrosine kinase interacting protein (Tip) of T lymphotropic Herpesvirus saimiri (HVS) is targeted to lipid rafts in T cells and downregulates TCR and CD4 surface expression. Here, we report that the membrane-proximal amphipathic helix preceding Tip's transmembrane (TM) domain mediates lipid raft localization and membrane deformation. In turn, this motif directs Tip's lysosomal trafficking and selective TCR downregulation. The amphipathic helix binds to the negatively charged lipids and induces liposome tubulation, the TM domain mediates oligomerization, and cooperation of the membrane-proximal helix with the TM domain is sufficient for localization to lipid rafts and lysosomal compartments, especially the mutivesicular bodies. These findings suggest that the membrane-proximal amphipathic helix and TM domain provide HVS Tip with the unique ability to deform the cellular membranes in lipid rafts and to downregulate TCRs potentially through MVB formation

    Carotid Intimal-Medial Thickness Is Not Increased in Women with Previous Gestational Diabetes Mellitus

    Get PDF
    BackgroundGestational diabetes mellitus (GDM) is known to increase the risk of cardiovascular diseases. Measuring the carotid artery intimal-medial thickness (CIMT) is a non-invasive technique used to evaluate early atherosclerosis and to predict future cardiovascular diseases. We examined the association between CIMT and cardiovascular risk factors in young Korean women with previous GDM.MethodsOne hundred one women with previous GDM and 19 women who had normal pregnancies (NP) were recruited between 1999 and 2002. At one year postpartum, CIMT was measured using high-resolution B-mode ultrasonography, and oral glucose tolerance tests were performed. Fasting glucose, glycated hemoglobin A1c (HbA1c), insulin levels and lipid profiles were also measured. CIMTs in the GDM and NP groups were compared, and the associations between CIMT and cardiovascular risk factors were analyzed in the GDM group.ResultsCIMT results of the GDM group were not significantly different from those of the NP group (GDM, 0.435±0.054 mm; NP, 0.460±0.046 mm; P=0.069). In the GDM group, a higher HbA1c was associated with an increase in CIMT after age adjustment (P=0.011). CIMT results in the group with HbA1c >6.0% were higher than those of the normal HbA1c (HbA1c ≤6.0%) (P=0.010). Nine of the patients who are type 2 diabetes mellitus converters within one year postpartum but showed no significant difference in CIMT results compared to NP group.ConclusionHigher HbA1c is associated with an increase in CIMT in women with previous GDM. However, CIMT at one year postpartum was not increased in these women compared to that in NP women

    500 MS/s 4-Bit Flash ADC with Complementary Architecture

    Get PDF
    This paper proposes a 500 MS/s 4-bit flash analog-to-digital converter (ADC) featuring a differential input voltage range of 1.2 Vpp operating at a supply voltage of 1.2 V. Although the proposed circuit utilizes a conventional flash ADC structure, its track and hold circuit, driving buffer, and preamp circuits corresponding to the analog stages are designed using complementary architecture to attain a sufficient swing range even at a low supply voltage. Notably, the proposed structure satisfies the error requirements. The error source of the flash ADC, such as the comparator’s input referred offset, did not degrade its performance, while the use of a calibration circuit, characterized by power consumption and area burdens and increased complexity, could also be avoided. Therefore, the proposed flash ADC met the error requirements, such as the comparator’s input referred offset, without the need for calibration circuits. The chip, fabricated using the TSMC 65 nm process, covers an area of 1,160 × 950 μm2 and consumes 78 mW of power. Furthermore, its signal-to-noise and distortion ratio and spurious-free dynamic range were measured to be 23.36 dB and 30.26 dB, respectively, at a sampling frequency of 500 MHz
    corecore