33 research outputs found

    Comparison of out-of-hospital cardiac arrests during the COVID-19 pandemic with those before the pandemic: an updated systematic review and meta-analysis

    Get PDF
    The coronavirus disease of 2019 (COVID-19) pandemic, directly and indirectly, affected the emergency medical care system and resulted in worse out-of-hospital cardiac arrest (OHCA) outcomes and epidemiological features compared with those before the pandemic. This review compares the regional and temporal features of OHCA prognosis and epidemiological characteristics. Various databases were searched to compare the OHCA outcomes and epidemiological characteristics during the COVID-19 pandemic with before the pandemic. During the COVID-19 pandemic, survival and favorable neurological outcome rates were significantly lower than before. Survival to hospitalization, return of spontaneous circulation, endotracheal intubation, and use of an automated external defibrillator (AED) decreased significantly, whereas the use of a supraglottic airway device, the incidence of cardiac arrest at home, and response time of emergency medical service (EMS) increased significantly. Bystander CPR, unwitnessed cardiac arrest, EMS transfer time, use of mechanical CPR, and in-hospital target temperature management did not differ significantly. A subgroup analysis of the studies that included only the first wave with those that included the subsequent waves revealed the overall outcomes in which the epidemiological features of OHCA exhibited similar patterns. No significant regional differences between the OHCA survival rates in Asia before and during the pandemic were observed, although other variables varied by region. The COVID-19 pandemic altered the epidemiologic characteristics, survival rates, and neurological prognosis of OHCA patients.Review registration: PROSPERO (CRD42022339435)

    Diagnostic value of neuroimaging for DNS in COP

    No full text

    Comparative Evaluation of the Prognosis of Septic Shock Patients from Before to After the Onset of the COVID-19 Pandemic: A Retrospective Single-Center Clinical Analysis

    No full text
    In this study, we investigated the mortality of septic shock patients visiting emergency departments (ED) before and after the coronavirus disease (COVID-19) pandemic onset. We retrospectively reviewed medical records and National Emergency Department Information System data of septic shock patients who visited the ED of a tertiary medical center in South Korea from February 2019 to February 2021. Following the COVID-19 pandemic onset, revised institutional ED processes included a stringent isolation protocol for patients visiting the ED. The primary goal of this study was to determine the mortality rate of septic shock patients from before and after the onset of the COVID-19 pandemic. Durations of vasopressor use, mechanical ventilation, intensive care unit stay, and hospitalization were investigated. The mortality rates increased from 24.8% to 35.8%, before and after COVID-19-onset, but the difference was not statistically significant (p = 0.079). No significant differences in other outcomes were found. Multivariable analysis revealed that the Simplified Acute Physiology Score III (SAPS III) was the only risk factor for mortality (OR 1.07; 95% CI 1.04-1.10), whereas COVID-19 pandemic was not included in the final model. The non-significant influence of the COVID-19 pandemic on septic shock mortality rates in the present study belies the actual mortality-influencing potential of the COVID-19 pandemic

    Association between Glasgow Coma Scale in Early Carbon Monoxide Poisoning and Development of Delayed Neurological Sequelae: A Meta-Analysis

    No full text
    A significant number of people experience delayed neurologic sequelae after acute carbon monoxide (CO) poisoning. The Glasgow Coma Scale (GCS) can be used to predict delayed neurologic sequelae occurrence efficiently and without any restrictions. Here, we investigated the association between a low GCS score observed in cases of early CO poisoning and delayed neurologic sequelae development through a meta-analysis. We systematically searched MEDLINE, EMBASE, and the Cochrane Library for studies on GCS as a predictor of delayed neurologic sequelae occurrence in patients with CO poisoning in June 2021. Two reviewers independently extracted study characteristics and pooled data. We also conducted subgroup analyses for the cutoff point for GCS. To assess the risk of bias of each included study, we used the quality in prognosis studies tool. We included 2328 patients from 10 studies. With regard to patients with acute CO poisoning, in the overall pooled odds ratio (OR) of delayed neurologic sequelae development, those with a low GCS score showed a significantly higher value and moderate heterogeneity (OR 2.98, 95% confidence interval (CI) 2.10–4.23, I2 = 33%). Additionally, in subgroup analyses according to the cutoff point of GCS, the development of delayed neurologic sequelae was still significantly higher in the GCS < 9 group (OR 2.80, 95% CI 1.91–4.12, I2 = 34%) than in the GCS < 10 or GCS < 11 groups (OR 4.24, 95% CI 1.55–11.56, I2 = 48%). An initial low GCS score in patients with early CO poisoning was associated with the occurrence of delayed neurologic sequelae. Additionally, GCS was quickly, easily, and accurately assessed. It is therefore possible to predict delayed neurologic sequelae and establish an active treatment strategy, such as hyperbaric oxygen therapy, to minimize neurological sequelae using GCS

    Recurrent Pulseless Ventricular Tachycardia Induced by Commotio Cordis Treated with Therapeutic Hypothermia

    No full text
    The survival rate of commotio cordis is low, and there is often associated neurological disability if return of spontaneous circulation (ROSC) can be achieved. We report a case of commotio cordis treated with therapeutic hypothermia (TH) that demonstrated a favorable outcome. A 16-year-old female was transferred to our emergency department (ED) for collapse after being struck in the chest with a dodgeball. She has no history of heart problems. She was brought to our ED with pulseless ventricular tachycardia (VT), and ROSC was achieved with defibrillation. She was comatose at our ED and was treated with TH at a target temperature of 33°C for 24 hours. After transfer to the intensive care unit, pulseless VT occurred, and defibrillation was performed twice. She recovered to baseline neurologic status with the exception of some memory difficulties

    Impact of a Smart-Ring-Based Feedback System on the Quality of Chest Compressions in Adult Cardiac Arrest: A Randomized Preliminary Study

    No full text
    This study aimed to assess the effectiveness of a novel chest compression (CC) smart-ring-based feedback system in a manikin simulation. In this randomized, crossover, controlled study, we evaluated the effect of smart-ring CC feedback on cardiopulmonary resuscitation (CPR). The learnability and usability of the tool were evaluated with the System Usability Scale (SUS). Participants were divided into two groups and each performed CCs with and without feedback 2 weeks apart, using different orders. The primary outcome was compression depth; the proportion of accurate-depth (5–6 cm) CCs, CC rate, and the proportion of complete CCs (≤1 cm of residual leaning) were assessed additionally. The feedback group and the non-feedback group showed significant differences in compression depth (52.1 (46.3–54.8) vs. 47.1 (40.5–49.9) mm, p = 0.021). The proportion of accurate-depth CCs was significantly higher in the interventional than in the control condition (88.7 (30.0–99.1) vs. 22.6 (0.0–58.5%), p = 0.033). The mean SUS score was 83.9 ± 8.7 points. The acceptability ranges were ‘acceptable’, and the adjective rating was ‘excellent’. CCs with smart-ring feedback could help achieve the ideal range of depth during CPR. The smart-ring may be a valuable source of CPR feedback

    Evaluation of Smartphone Applications for Cardiopulmonary Resuscitation Training in South Korea

    No full text
    Objective. There are many smartphone-based applications (apps) for cardiopulmonary resuscitation (CPR) training. We investigated the conformity and the learnability/usability of these apps for CPR training and real-life supports. Methods. We conducted a mixed-method, sequential explanatory study to assess CPR training apps downloaded on two apps stores in South Korea. Apps were collected with inclusion criteria as follows, Korean-language instruction, training features, and emergency supports for real-life incidents, and analyzed with two tests; 15 medical experts evaluated the apps’ contents according to current Basic Life Support guidelines in conformity test, and 15 nonmedical individuals examined the apps using System Usability Scale (SUS) in the learnability/usability test. Results. Out of 79 selected apps, five apps were included and analyzed. For conformity (ICC, 0.95, p<0.001), means of all apps were greater than 12 of 20 points, indicating that they were well designed according to current guidelines. Three of the five apps yielded acceptable level (greater than 68 of 100 points) for learnability/usability. Conclusion. All the included apps followed current BLS guidelines and a majority offered acceptable learnability/usability for layperson. Current and developmental smartphone-based CPR training apps should include accurate CPR information and be easy to use for laypersons that are potential rescuers in real-life incidents. For Clinical Trials. This is a clinical trial, registered at the Clinical Research Information Service (CRIS, cris.nih.go.kr), number KCT0001840

    Endotracheal Intubation Using a Direct Laryngoscope and the Protective Performances of Respirators: A Randomized Trial

    No full text
    Purpose. Emergency physicians are at risk for infection during invasive procedures, and the respirators can reduce this risk. This study aimed to determine whether endotracheal intubation using direct laryngoscopes affected protection performances of respirators. Methods. A randomized crossover study of 24 emergency physicians was performed. We performed quantitative fit tests using respirators (cup type, fold type without a valve, and fold type with a valve) before and during intubation. The primary outcome was respirators’ fit factors (FF), and secondary outcomes were acceptable protection (percentage of scores above 100 FF [FF%]). Results. 24 pieces of data were analyzed. Compared to fold-type respirator without a valve, FF and FF% values were lower when participants wore a cup-type respirator (200 FF [200-200] versus 200 FF [102.75–200], 100% [78.61–100] versus 74.16% [36.1–98.9]; all P<0.05) or fold-type respirator with a valve (200 FF [200-200] versus 142.5 FF [63.50–200], 100% [76.10–100] versus 62.50% [8.13–100]; all P<0.05). There were no significant differences in intubation time and success rate according to respirator types. Conclusions. Motion during endotracheal intubation using direct laryngoscopes influenced the protective performance of some respirators. Therefore, emergency physicians should identify and wear respirators that provide the best personalized fit for intended tasks
    corecore