6,338 research outputs found

    Development of an intelligent hypertext manual for the space shuttle hazardous gas detection system

    Get PDF
    A computer-based Integrated Knowledge System (IKS), the Intelligent Hypertext Manual (IHM), is being developed for the Space Shuttle Hazardous Gas Detection System (HGDS) at the Huntsville Operations Support Center (HOSC). The IHM stores all HGDS related knowledge and presents them in an interactive and intuitive manner. The IHM's purpose is to provide HGDS personnel with the capabilities of: enhancing the interpretation of real time data; recognizing and identifying possible faults in the Space Shuttle sub-system related to hazardous gas detections; locating applicable documentation related to procedures, constraints, and previous fault histories; and assisting in the training of personnel

    A wall interference assessment/correction system

    Get PDF
    A Wall Signature method, the Hackett method, has been selected to be adapted for the 12-ft Wind Tunnel wall interference assessment/correction (WIAC) system in the present phase. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interferences at the model location. The Wall Signature method will be formulated for application to the unique geometry of the 12-ft Tunnel. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method-Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. Each set of wind tunnel/test article numerical simulations provides data to validate the WIAC method. A numerical wind tunnel test simulation is initiated to validate the WIAC methods developed in the project. In the present reported period, the blockage correction has been developed and implemented for a rectangular tunnel as well as the 12-ft Pressure Tunnel. An improved wall interference assessment and correction method for three-dimensional wind tunnel testing is presented in the appendix

    Electronic structure and physical properties of the spinel-type phase of BeP2N4 from all-electron density functional calculations

    Get PDF
    Using density-functional-theory-based ab initio methods, the electronic structure and physical properties of the newly synthesized nitride BeP2N4 with a phenakite-type structure and the predicted high-pressure spinel phase of BeP2N4 are studied in detail. It is shown that both polymorphs are wide band-gap semiconductors with relatively small electron effective masses at the conduction-band minima. The spinel-type phase is more covalently bonded due to the increased number of P-N bonds for P at the octahedral sites. Calculations of mechanical properties indicate that the spinel-type polymorph is a promising superhard material with notably large bulk, shear, and Young’s moduli. Also calculated are the Be K, P K, P L3, and N K edges of the electron energy-loss near-edge structure for both phases. They show marked differences because of the different local environments of the atoms in the two crystalline polymorphs. These differences will be very useful for the experimental identification of the products of high-pressure syntheses targeting the predicted spinel-type phase of BeP2N4

    On Conditional Statistics in Scalar Turbulence: Theory vs. Experiment

    Full text link
    We consider turbulent advection of a scalar field T(\B.r), passive or active, and focus on the statistics of gradient fields conditioned on scalar differences ΔT(R)\Delta T(R) across a scale RR. In particular we focus on two conditional averages ⟨∇2T∣ΔT(R)⟩\langle\nabla^2 T\big|\Delta T(R)\rangle and ⟨∣∇T∣2∣ΔT(R)⟩\langle|\nabla T|^2\big|\Delta T(R) \rangle. We find exact relations between these averages, and with the help of the fusion rules we propose a general representation for these objects in terms of the probability density function P(ΔT,R)P(\Delta T,R) of ΔT(R)\Delta T(R). These results offer a new way to analyze experimental data that is presented in this paper. The main question that we ask is whether the conditional average ⟨∇2T∣ΔT(R)⟩\langle\nabla^2 T\big| \Delta T(R)\rangle is linear in ΔT\Delta T. We show that there exists a dimensionless parameter which governs the deviation from linearity. The data analysis indicates that this parameter is very small for passive scalar advection, and is generally a decreasing function of the Rayleigh number for the convection data.Comment: Phys. Rev. E, Submitted. REVTeX, 10 pages, 5 figs. (not included) PS Source of the paper with figure available at http://lvov.weizmann.ac.il/onlinelist.html#unpub

    A wall interference assessment/correction system

    Get PDF
    A Wall Signature method originally developed by Hackett was selected to be adapted for the Ames 12-ft Wind Tunnel Wall Interference Assessment/Correction (WIAC) System in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interference at the model location. The lifting interference will be treated separately by representing in a horseshoe vortex system for the model's lifting effects. The development and implementation of a working prototype will be completed, delivered, and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method - Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. The following two additional tasks are included in the supplement No. 1 to the basic Grant. On-line wall interference calculation: The developed wall signature method (modified Hackett's method) for Ames 12-ft Tunnel will be the pre-computed coefficients which facilitate the on-line calculation of wall interference; and support system effects estimation: The effects on the wall pressure measurements due to the presence of the model support systems will be evaluated
    • …
    corecore