8 research outputs found

    Takotsubo Cardiomyopathy as a Delayed Complication with a Herbicide Containing Glufosinate Ammonium in a Suicide Attempt: A Case Report

    Get PDF
    Background. Glufosinate ammonium has a famous delayed complication as respiratory failure, however, delayed cardiogenic complication is not well known. Objectives. The aim of this study is to report a takotsubo cardiomyopathy as a delayed complication of glufosinate ammonium for suicide attempt. Case Report. A 75-year-old woman ingested about 90 mL of Basta, herbicide for suicide attempt at arousal during sleep. She came to our hospital at twelve hours after ingesting. She was admitted to our hospital for fear of delayed respiratory failure. Actually, she felt down to respiratory failure, needing a ventilator with intubation at 20 hours after ingesting. Procedure around respiratory management had smoothly done with no delay. Her vital status had been stable, however, she felt down to circulatory failure and diagnosed as Takotsubo cardiomyopathy at about 41 hours after ingestion. There was no trigger activities or events to evoke mental and physical stresses. Conclusion. We could successfully manage takotsubo cardiomyopathy resulted in circulatory failure in a patient with glufosinate poisoning for suicide attempt. Takotsubo cardiomyopathy should be taken into consideration if circulatory failure is observed for unexplained reasons

    Spinal cord injury without radiological abnormality due to a fall while using an abdominal roller: A report of two cases

    No full text
    Abstract Background In recent years, various home‐use health devices have gained popularity. The abdominal roller is one of these. Spinal cord injury without radiological abnormality is known to occur even with relatively minor injuries, but there are few reports of such injuries caused by a roller. Case Presentation Two cases of spinal cord injuries caused by a roller are reported. In both cases, injuries occurred during the standing rollout by a patient in an inebriated state, and the patients were rushed to an emergency department. Conclusion Because the use of abdominal rollers may result in extremely serious disabilities, it is necessary to emphasize the appropriate use of such equipment

    The utility of resuscitative endovascular balloon occlusion of the aorta for temporary hemostasis after extensive bilateral lower extremity injuries: A case report

    No full text
    A 75-year-old pedestrian was struck by a truck and in shock with both lower extremities significantly deformed, with injuries extending proximally to the inguinal region and degloving injuries. Resuscitative endovascular balloon occlusion of the aorta was performed to achieve temporary hemostasis and the patient became hemodynamically stable. Following stabilization, both lower extremities were amputated. Resuscitative endovascular balloon occlusion of the aorta may be effective to achieve temporary hemostasis in patients with extensive injuries of the lower extremities, especially with extension to the inguinal region which precludes use of a tourniquet. Keywords: Bilateral lower extremity injuries, Hemorrhagic shock, Resuscitative endovascular balloon occlusion of the aorta (REBOA), Temporary hemostasi

    Cardiopulmonary resuscitation in adults over 80 : outcome and the perception of appropriateness by clinicians

    No full text

    Cardiopulmonary resuscitation in adults over 80 : outcome and the perception of appropriateness by clinicians

    No full text
    OBJECTIVES: To determine the prevalence of clinician perception of inappropriate cardiopulmonary resuscitation (CPR) regarding the last out‐of‐hospital cardiac arrest (OHCA) encountered in an adult 80 years or older and its relationship to patient outcome. DESIGN: Subanalysis of an international multicenter cross‐sectional survey (REAPPROPRIATE). SETTING: Out‐of‐hospital CPR attempts registered in Europe, Israel, Japan, and the United States in adults 80 years or older. PARTICIPANTS: A total of 611 clinicians of whom 176 (28.8%) were doctors, 123 (20.1%) were nurses, and 312 (51.1%) were emergency medical technicians/paramedics. RESULTS AND MEASUREMENTS: The last CPR attempt among patients 80 years or older was perceived as appropriate by 320 (52.4%) of the clinicians; 178 (29.1%) were uncertain about the appropriateness, and 113 (18.5%) perceived the CPR attempt as inappropriate. The survival to hospital discharge for the “appropriate” subgroup was 8 of 265 (3.0%), 1 of 164 (.6%) in the “uncertain” subgroup, and 2 of 107 (1.9%) in the “inappropriate” subgroup (P = .23); 503 of 564 (89.2%) CPR attempts involved non‐shockable rhythms. CPR attempts in nursing homes accounted for 124 of 590 (21.0%) of the patients and were perceived as appropriate by 44 (35.5%) of the clinicians; 45 (36.3%) were uncertain about the appropriateness; and 35 (28.2%) perceived the CPR attempt as inappropriate. The survival to hospital discharge for the nursing home patients was 0 of 107 (0%); 104 of 111 (93.7%) CPR attempts involved non‐shockable rhythms. Overall, 36 of 543 (6.6%) CPR attempts were undertaken despite a known written do not attempt resuscitation decision; 14 of 36 (38.9%) clinicians considered this appropriate, 9 of 36 (25.0%) were uncertain about its appropriateness, and 13 of 36 (36.1%) considered this inappropriate. CONCLUSION: Our findings show that despite generally poor outcomes for older patients undergoing CPR, many emergency clinicians do not consider these attempts at resuscitation to be inappropriate. A professional and societal debate is urgently needed to ensure that first we do not harm older patients by futile CPR attempts. J Am Geriatr Soc 68:39–45, 201
    corecore