15 research outputs found

    COVID-19: Rapid antigen detection for SARS-CoV-2 by lateral flow assay: A national systematic evaluation of sensitivity and specificity for mass-testing

    Get PDF
    Background Lateral flow device (LFD) viral antigen immunoassays have been developed around the world as diagnostic tests for SARS-CoV-2 infection. They have been proposed to deliver an infrastructure-light, cost-economical solution giving results within half an hour. Methods LFDs were initially reviewed by a Department of Health and Social Care team, part of the UK government, from which 64 were selected for further evaluation from 1st August to 15th December 2020. Standardised laboratory evaluations, and for those that met the published criteria, field testing in the Falcon-C19 research study and UK pilots were performed (UK COVID-19 testing centres, hospital, schools, armed forces). Findings 4/64 LFDs so far have desirable performance characteristics (orient Gene, Deepblue, Abbott and Innova SARS-CoV-2 Antigen Rapid Qualitative Test). All these LFDs have a viral antigen detection of >90% at 100,000 RNA copies/ml. 8951 Innova LFD tests were performed with a kit failure rate of 5.6% (502/8951, 95% CI: 5.1–6.1), false positive rate of 0.32% (22/6954, 95% CI: 0.20–0.48). Viral antigen detection/sensitivity across the sampling cohort when performed by laboratory scientists was 78.8% (156/198, 95% CI 72.4–84.3). Interpretation Our results suggest LFDs have promising performance characteristics for mass population testing and can be used to identify infectious positive individuals. The Innova LFD shows good viral antigen detection/sensitivity with excellent specificity, although kit failure rates and the impact of training are potential issues. These results support the expanded evaluation of LFDs, and assessment of greater access to testing on COVID-19 transmission. Funding Department of Health and Social Care. University of Oxford. Public Health England Porton Down, Manchester University NHS Foundation Trust, National Institute of Health Research

    Characterization of the physical state of spray-dried inulin.

    Full text link
    Modulated differential scanning calorimetry, wide angle x-ray scattering, and environmental scanning electron microscopy were used to investigate the physical and morphological properties of chicory root inulin spray dried under different conditions. When the feed temperature increased up to 80 degrees C, the average degree of polymerization of the solubilized fraction increased, leading to a higher glass transition temperature (Tg). Above 80 degrees C, the samples were completely amorphous, and the Tg did not change. The starting material was semicrystalline, and the melting region was composed of a dual endotherm; the first peak subsided as the feed temperature increased up to a temperature of 70 degrees C, whereas above 80 degrees C, no melting peak was observed as the samples were completely amorphous. To a lesser extent, the inlet air temperature of 230 degrees C allowed a higher amorphous content of the samples than at 120-170 degrees C but induced a blow-out of the particles

    Household drinking water in developing countries: a systematic review of microbiological contamination between source and point-of-use

    No full text
    Summary Objective To assess the extent and causes of microbiological contamination of household drinking water between source and point-of-use in developing countries. Methods A systematic meta-analysis of 57 studies measuring bacteria counts for source water and stored water in the home to assess how contamination varied between settings. Results The bacteriological quality of drinking water significantly declines after collection in many settings. The extent of contamination after water collection varies considerably between settings, but is proportionately greater where faecal and total coliform counts in source water are low. Conclusions Policies that aim to improve water quality through source improvements may be compromised by post-collection contamination. Safer household water storage and treatment is recommended to prevent this, together with point-of-use water quality monitoring
    corecore