5 research outputs found

    Neutrino cross sections and nuclear structure

    Get PDF
    The effects of the theoretical uncertainties in the description of neutrino-nucleus cross sections for supernova neutrino energies are investigated.Comment: Contribution to NOW 2008, Conca Specchiulla (Otranto, Italy), September 6-13 200

    Test-retest reliability of diffusion tensor imaging of the liver at 3.0\ua0T.

    No full text
    PURPOSE: This study was done to evaluate test-retest reliability of liver diffusion tensor imaging (LDTI). MATERIALS AND METHODS: Ten healthy volunteers (median age 23 years) underwent two LDTI scans on a 3.0 T magnet during two imaging sessions separated by 2 weeks (session-1/-2, respectively). Fifteen gradient directions and b values of 0-1,000 s/mm(2) were used. Two radiologists in consensus assessed liver apparent diffusion coefficient (ADC) and fraction of anisotropy (FA) values on ADC and FA maps at four reference levels, namely: right upper level (RUL), right lower level (RLL), left upper level (LUL) and left lower level (LLL). We then assessed (a) whether ADC and FA values overlapped when measured on different levels within the same imaging session or between different imaging sessions; (b) the degree of variability on an intra-session and inter-session basis, respectively, using the coefficient of variation (CV). RESULTS: In sessions 1 and 2, the ADC/FA values were significantly larger in the left liver lobe (LUL/LLL) compared to right liver lobe (RUL/RLL) (p < 0.05/6). Intra-session CVs were 9.51 % (session 1) and 9.73 % (session 2) for ADC, and 12.93 % (session 1) and 11.82 % (session 2) for FA, respectively. When comparing RUL, RLL, LUL and LLL on an inter-session basis, CVs were 6.52, 8.20, 6.52 and 11.06 % for ADC, and 15.42, 15.80, 15.42 and 6.80 % for FA, respectively. CONCLUSION: LDTI provides consistent and repeatable measurements. However, since larger left lobe ADC/FA values can be attributed to artefacts, right lobe values should be considered the most reliable measurements of water diffusivity within the live

    Is there a systematic bias of apparent diffusion coefficient (ADC) measurements of the breast if measured on different workstations? An inter- and intra-reader agreement study

    Full text link
    OBJECTIVES To evaluate the influence of post-processing systems, intra- and inter-reader agreement on the variability of apparent diffusion coefficient (ADC) measurements in breast lesions. METHODS Forty-one patients with 41 biopsy-proven breast lesions gave their informed consent and were included in this prospective IRB-approved study. Magnetic resonance imaging (MRI) examinations were performed at 1.5 T using an EPI-DWI sequence, with b-values of 0 and 1000 s/mm(2). Two radiologists (R1, R2) reviewed the images in separate sessions and measured the ADC for lesion, using MRI-workstation (S-WS), PACS-workstation (P-WS) and a commercial DICOM viewer (O-SW). Agreement was evaluated using the intraclass correlation coefficient (ICC), Bland-Altman plots and coefficient of variation (CV). RESULTS Thirty-one malignant, two high-risk and eight benign mass-like lesions were analysed. Intra-reader agreement was almost perfect (ICC-R1 = 0.974; ICC-R2 = 0.990) while inter-reader agreement was substantial (ICC from 0.615 to 0.682). Bland-Altman plots revealed a significant bias in ADC values measured between O-SW and S-WS (P = 0.025), no further systematic differences were identified. CV varied from 6.8 % to 7.9 %. CONCLUSION Post-processing systems may have a significant, although minor, impact on ADC measurements in breast lesions. While intra-reader agreement is high, the main source of ADC variability seems to be caused by inter-reader variation. KEY POINTS • ADC provides quantitative information on breast lesions independent from the system used. • ADC measurement using different workstations and software systems is generally reliable. • Systematic, but minor, differences may occur between different post-processing systems. • Inter-reader agreement of ADC measurements exceeded intra-reader agreement
    corecore