282 research outputs found

    Effect of Auricular Acupressure on Peri- and Early Postmenopausal Women with Anxiety: A Double-Blinded, Randomized, and Controlled Pilot Study

    Get PDF
    We tested effects of auricular acupressure on peri- and early postmenopausal women with anxiety (PPWA). Fifty PPWA were randomly assigned to the auricular acupressure group (AG) or the sham group (SG). After 3 meals and before sleep every day for 4 weeks, the AG received auricular acupressure on the bilateral ear shenmen and subcortex points for 3 min per point on alternating ears. The SG received sham auricular acupressure. The Alprazolam was reduced from 0.5 mg/day at baseline to 0.3 mg/day 4 weeks after auricular acupressure (4 W) in the AG (P < .05) whereas maintained at 0.5 mg/day in the SG (P > .05). The Zolpidem was reduced from 3.0 mg/day at baseline to 1.5 mg/day at 4 W (P < .05) whereas was reduced from 2.4 mg/day to 1.9 mg/day at 4 W in the SG (P > .05), thus, significant tapering medication, suggesting auricular acupressure is helpful to PPWA

    SERVE 4U: evaluación de competencias de servicio al cliente a través de cuestionario virtual

    Get PDF
    Curso de Especial InterésSe diseña un plan de mercadeo para crear el cuestionario SERVE4U, este evalúa las competencias con relación al servicio al cliente. El cuestionario contó con la validación de jueces, coeficiente RGW y el estadístico Kolmogorov Smirnov y finalmente se compone por 28 ítems. Concluyendo que el instrumento es válido y confiable para ser aplicado en aspirantes a cargos comerciales.1. RESUMEN. 2. JUSTIFICACIÓN. 3. MARCO REFERENCIAL. 4. OBJETIVOS. 5. MÉTODO. 6. ESTUDIO DE MERCADO. 7. RESULTADOS. 8. CONCLUSIONES. 9. REFERENCIAS.PregradoPsicólog

    Using the computer-based feedback (CBF) system to investigate the juniorphysicians’s and clinical-instructors perceptions for the benefits of general medicine clinical-instructors training program

    Get PDF
    Background: The purpose of this study is to examine the clinical-instructors and junior-physicians (residents and interns) perceptions for the general-medicine training program by using bi-directional interactive and self-assessments computer-based feedback (CBF) and paper-based multisource feedback assessment (PBMFA) systems for the efficiency and benefit evaluation.Methods: Between 2011 January to 2013 December, junior-physicians and their clinical-instructors in the same medical team were enrolled consecutively for monitoring the CBF scores gave by each other after each clinical course. A total of 321 residents, 298 interns and 110 clinical-instructors who participated in the core competency general-medicine training program in 6-months period were included in the study. The CBF and PBMFA evaluations are undergone paralleled to gather the suggested information in different levels of Kirkpatrick evolutional theory.Results: The results showed that lecturers, being 5-10 years as attending physicians, internal medicine sub-specialty clinical-instructors are most benefit from the general medicine training program. Accordingly, the CBF scores of junior-physicians was positively correlated with the times (&gt; 3-times) of exposure to the medical teams that leaded by qualified clinical-instructors. Both clinical-instructors and junior-physicians have positive attitude to the value of the general-medicine training program. Interestingly, a good consistency was existed between residents CBF scores and PBMFA grades for their core-competency performance. Comparatively, the overall perception of clinical-instructors and junior-physicians for the general-medicine training was very positive.Conclusions: Clinical-instructors and junior-physicians had positive perception of CBF and PBMFA systems which could give us different information to improve and strength the further core-competency general-medicine training program by appropriate utilization

    Association of ORAI1 Haplotypes with the Risk of HLA-B27 Positive Ankylosing Spondylitis

    Get PDF
    Ankylosing spondylitis (AS) is a chronic inflammation of the sacroiliac joints, spine and peripheral joints. The aetiology of ankylosing spondylitis is still unclear. Previous studies have indicated that genetics factors such as human leukocyte antigen HLA-B27 associates to AS susceptibility. We carried out a case-control study to determine whether the genetic polymorphisms of ORAI1 gene, a major component of store-operated calcium channels that involved the regulation of immune system, is a susceptibility factor to AS in a Taiwanese population. We enrolled 361 AS patients fulfilled the modified New York criteria and 379 controls from community. Five tagging single nucleotides polymorphisms (tSNPs) at ORAI1 were selected from the data of Han Chinese population in HapMap project. Clinical statuses of AS were assessed by the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Functional Index (BASFI), and Bath Ankylosing Spondylitis Global Index (BAS-G). Our results indicated that subjects carrying the minor allele homozygote (CC) of the promoter SNP rs12313273 or TT homozygote of the SNP rs7135617 had an increased risk of HLA-B27 positive AS. The minor allele C of 3′UTR SNP rs712853 exerted a protective effect to HLA-B27 positive AS. Furthermore, the rs12313273/rs7135617 pairwise allele analysis found that C-G (OR 1.69, 95% CI 1.27, 2.25; p = 0.0003) and T-T (OR 1.75, 95% CI 1.36, 2.27; p<0.0001) haplotypes had a significantly association with the risk of HLA-B27-positive AS in comparison with the T-G carriers. This is the first study that indicate haplotypes of ORAI1 (rs12313273 and rs7135617) are associated with the risk of HLA-B27 positive AS

    Near-Infrared Light Device Can Improve Intravenous Cannulation in Critically Ill Children

    Get PDF
    critically ill children; intravenous cannulation; near-infrared light device Background: Vascular access in critically ill children can be a real challenge for medical staff. In order to evaluate the effectiveness of a near-infrared light vein-viewing device for critically ill children, 60 pediatric inpatients were enrolled in a randomized prospective observation trial for intravenous cannulation. Methods: The patients&apos; demographic data, mean time required to find the first available vessel, first-attempt success rate, mean number of attempts per patient, and the total time taken on the attempts per patient were compared. Results: Less time was required to find the first available vessel in the near-infrared light device group compared with the control group (126.37 vs. 383.61 seconds; p Z 0.027). In addition, the near-infrared light device group had a fewer number of attempts compared with the control group (median 1 vs. 2; p Z 0.004), and also a shorter total time of attempts per patient compared with the control group (186.16 vs. 497.23 seconds; p Z 0.014). Conclusion: The use of a near-infrared light vein-viewing device for vascular access in critically ill children can decrease the total medical time and cost

    Improved Image Quality for Static BLADE Magnetic Resonance Imaging Using the Total-Variation Regularized Least Absolute Deviation Solver.

    Get PDF
    In order to improve the image quality of BLADE magnetic resonance imaging (MRI) using the index tensor solvers and to evaluate MRI image quality in a clinical setting, we implemented BLADE MRI reconstructions using two tensor solvers (the least-squares solver and the L1 total-variation regularized least absolute deviation (L1TV-LAD) solver) on a graphics processing unit (GPU). The BLADE raw data were prospectively acquired and presented in random order before being assessed by two independent radiologists. Evaluation scores were examined for consistency and then by repeated measures analysis of variance (ANOVA) to identify the superior algorithm. The simulation showed the structural similarity index (SSIM) of various tensor solvers ranged between 0.995 and 0.999. Inter-reader reliability was high (Intraclass correlation coefficient (ICC) = 0.845, 95% confidence interval: 0.817, 0.87). The image score of L1TV-LAD was significantly higher than that of vendor-provided image and the least-squares method. The image score of the least-squares method was significantly lower than that of the vendor-provided image. No significance was identified in L1TV-LAD with a regularization strength of λ= 0.4-1.0. The L1TV-LAD with a regularization strength of λ= 0.4-0.7 was found consistently better than least-squares and vendor-provided reconstruction in BLADE MRI with a SENSitivity Encoding (SENSE) factor of 2. This warrants further development of the integrated computing system with the scanner
    corecore