5 research outputs found

    Physico-mathematical model for determining the direction in space to point sources of gamma radiation using spherical absorber

    No full text
    Physico-mathematical model for determining the direction in space to point sources of gamma radiation using a spherical absorber was developed. CdTe detectors of appropriate sizes are placed in the regular pyramid tops under absorber. The physico-mathematical model allowed, taking into account the exponential attenuation of gamma radiation by the absorber, to find the distance from the location of any CdTe sensor to the surface of sphere in any direction in space. Calculated information and signal received from the detectors, correlate to each other. The ratios found depend on the angle to the source of gamma radiation and represent the ratio of transmittance coefficients for four sensors. A methodology for locating the developed device in space, which allowed to obtain dependence of the calculated ratios from the angle in space for θ = 90° and φ from 0° to 360° in increments of 15° was proposed. Each direction in space corresponds to a set of six respective ratios

    Requirements for metrological and technical characteristic of measuring blocks in uav (unmanned aerial vehicle) for radiation reconnaissance

    No full text
    В статье исследуется возможность получения качественной измеряемой дозиметрической и спектрометрической информации измерительным блоком БПЛА при ведении радиационной разведки местности. Предлагается подход к выбору оптимальных метролого-технических характеристик измерительных блоков.У статті досліджується можливість отримання якісної вимірювальної дозиметричної та спектрометричної інформації вимірювальним блоком БПЛА під час ведення радіаційної розвідки місцевості. Пропонується підхід до вибору оптимальних метролого-технічних характеристик вимірювальних блоків.The article examines possibility of receiving qualitative dosimetric and spectrometric information by the measuring block during radiation reconnaissance of terrain. Proposed an approach for choice of optimal metrological and technical characteristics of measuring blocks

    Increasing the resolving power of determining the point gamma-radiation source direction in the precision method

    No full text
    Experiments have demonstrated the possibility of increasing the resolving power of determining the point gamma-radiation source direction in the precision method. The work involved reducing the step of the angle of rotation of an asymmetric absorber and shifting the detector relative to the maximum-minimum absorber thickness boundary. The ¹³⁷Cs gamma-radiation source direction was determined within the angles of the maximum and minimum thickness boundaries of the asymmetric absorber. The detector position was investigated for the maximum thickness of the asymmetric absorber on the boundary between the maximum and minimum thickness, and for the minimum thickness. The optimal position of the detector was found for the asymmetric absorber boundary, enabling to determine the maximum count rate in the gamma source direction. A specific position of the detector enables observing an increasing gamma radiation scattering over the copper-lead surface. The experiment used absorbers with spectrometric telluride-cadmium detectors. Information from the detectors was output to four multichannel gamma-radiation impulse analysers, which operated simultaneously in the spectrometer mode

    THE USE OF SILICON PIN DETECTORS FOR RECORDING PARAMETERS OF NUCLEAR EXPLOSION

    No full text
    Проанализированы недостатки регистрации параметров ядерных взрывов. Разработан метод и аппаратура для автоматического измерения мощности ядерного взрыва и направления на центр взрыва на основе кремниевых РІN детекторов площадью 10 мм×10 мм и многоканальных анализаторов импульсов с персональным компьютером.Проаналізовано недоліки реєстрації параметрів ядерних вибухів. Розроблені метод і апаратура для автоматичного вимірювання потужності ядерного вибуху і спрямування на центр вибуху на основі кремнієвих РІN детекторів площею 10 мм×10 мм і багатоканальних аналізаторів імпульсів з персональним комп'ютером.Analyzed disadvantages of nuclear explosions registration parameters. Method and equipment for automatically measuring the power of a nuclear explosion and the direction for the center of the explosion based on silicon PIN detectors an area of 10 mm×10 mm and multichannel pulse analyzers with a personal computer been developed

    Analysis of the features of influence the spectral-angular characteristics of the radiation factor on the protective properties of materials

    No full text
    В работе обосновывается необходимость учёта спектрально-угловых характеристик радиационного фактора путём анализа защитных свойств материалов, а также создаваемой гамма-нейтронным излучением неравномерности облучения.У роботі обґрунтовується необхідність врахування спектрально-кутових характеристик радіаційного фактора шляхом аналізу захисних властивостей матеріалів, а також створюваної гамма-нейтронним випромінюванням нерівномірності опромінення.The paper substantiates the necessity of taking into account the the spectral- angular characteristics of the radiation factor by analyzing the protective properties of materials, as well as non-uniformity produced by irradiation of gamma-neutron radiation
    corecore