1,271 research outputs found

    Collective autobiographical reflexivity on active and compassionate citizenship in the COVID-19 crisis

    Get PDF
    Since the outbreak of the coronavirus pandemic, socio-economic inequalities have become exacerbated and COVID-19 related hate crimes have increased. This paper explores how citizenship education might be reimagined in response to this context, with the vision of rebuilding a more equitable and compassionate society. By using a collective autobiographical writing approach, this study documented six different autobiographical reflexivities of citizenship education scholars who were from different parts of the world: China, South Korea, the Philippines, the United States, Nepal and the United Kingdom. It also observed the way the pandemic played out in the location where they were situated during the research as well as how it played out in their countries of origin, and further, how it affected the civic development in each context. The scholars' range of autobiographical expressions resulted in insights for developing a type of citizenship education, namely, education for active and compassionate citizenship

    Aging affects two modes of nanoleakage expression in bonded dentin

    Get PDF
    Water sorption into resin-dentin interfaces precedes hydrolytic degradation. We hypothesized that these processes are morphologically manifested by the uptake of ammoniacal silver nitrate, which is thought to trace hydrophilic domains and water-filled channels within matrices. Water sorption is thought to be nonuniform and can be traced by the use of silver nitrate. Human teeth bonded with an experimental filled-adhesive were aged in artificial saliva (experimental) or non-aqueous mineral oil (control). Specimens retrieved for up to a 12-month period were immersed in 50 wt% ammoniacal silver nitrate and examined by transmission electron microscopy for identification of the changes in their silver uptake. Reticular silver deposits initially identified within the bulk of hybrid layers in the experimental group were gradually reduced over time, but were subsequently replaced by similar deposits that were located along the hybrid layer-adhesive interface. Silver uptake in water-binding domains of the adhesive layers increased with aging, resulting in water tree formation. These water-filled channels may act as potential sites for hydrolytic degradation of resin-dentin bonds.published_or_final_versio

    Use of continuous subcutaneous anesthetic infusion in cardiac surgical patients after median sternotomy

    Get PDF
    The use of opioid analgesics to control pain after median sternotomy in cardiac surgical patients is worldwide accepted and established. However, opioids have a wide range of possible side effects, concerning prolonged extubation time, gastrointestinal tract dyskinesia and urinary tract disorders mostly retention. All these may lead to a prolonged ICU stay or overall hospitalization time increase

    Measuring every particle's size from three-dimensional imaging experiments

    Full text link
    Often experimentalists study colloidal suspensions that are nominally monodisperse. In reality these samples have a polydispersity of 4-10%. At the level of an individual particle, the consequences of this polydispersity are unknown as it is difficult to measure an individual particle size from microscopy. We propose a general method to estimate individual particle radii within a moderately concentrated colloidal suspension observed with confocal microscopy. We confirm the validity of our method by numerical simulations of four major systems: random close packing, colloidal gels, nominally monodisperse dense samples, and nominally binary dense samples. We then apply our method to experimental data, and demonstrate the utility of this method with results from four case studies. In the first, we demonstrate that we can recover the full particle size distribution {\it in situ}. In the second, we show that accounting for particle size leads to more accurate structural information in a random close packed sample. In the third, we show that crystal nucleation occurs in locally monodisperse regions. In the fourth, we show that particle mobility in a dense sample is correlated to the local volume fraction.Comment: 7 pages, 5 figure

    Optical phase conjugation for turbidity suppression in biological samples

    Get PDF
    Elastic optical scattering, the dominant light-interaction process in biological tissues, prevents tissues from being transparent. Although scattering may appear stochastic, it is in fact deterministic in nature. We show that, despite experimental imperfections, optical phase conjugation (Ξ» = 532 nm) can force a transmitted light field to retrace its trajectory through a biological target and recover the original light field. For a 0.69-mm-thick chicken breast tissue section, we can enhance point-source light return by a factor of ~5 x 10^3 and achieve a light transmission enhancement factor of 3.8 within a collection angle of 29Β°. Additionally, we find that the reconstruction's quality, measured by the width of the reconstructed point source, is independent of tissue thickness (up to a thickness of 0.69 mm). This phenomenon may be used to enhance light transmission through tissue, enable measurement of small tissue movements, and form the basis of new tissue imaging techniques

    Synthesis, Purification and Crystallization of Guanine-rich RNA Oligonucleotides

    Get PDF
    Guanine-rich RNA oligonucleotides display many novel structural motifs in recent crystal structures. Here we describe the procedures of the chemical synthesis and the purification of such RNA molecules that are suitable for X-ray crystallographic studies. Modifications of the previous purification methods allow us to obtain better yields in shorter time. We also provide 24 screening conditions that are very effective in crystallization of the guanine-rich RNA oligonucleotides. Optimal crystallization conditions are usually achieved by adjustment of the concentration of the metal ions and pH of the buffer. Crystals obtained by this method usually diffract to high resolution

    Evaluation of a fiberoptic-based system for measurement of optical properties in highly attenuating turbid media

    Get PDF
    BACKGROUND: Accurate measurements of the optical properties of biological tissue in the ultraviolet A and short visible wavelengths are needed to achieve a quantitative understanding of novel optical diagnostic devices. Currently, there is minimal information on optical property measurement approaches that are appropriate for in vivo measurements in highly absorbing and scattering tissues. We describe a novel fiberoptic-based reflectance system for measurement of optical properties in highly attenuating turbid media and provide an extensive in vitro evaluation of its accuracy. The influence of collecting reflectance at the illumination fiber on estimation accuracy is also investigated. METHODS: A neural network algorithm and reflectance distributions from Monte Carlo simulations were used to generate predictive models based on the two geometries. Absolute measurements of diffuse reflectance were enabled through calibration of the reflectance system. Spatially-resolved reflectance distributions were measured in tissue phantoms at 405 nm for absorption coefficients (ΞΌ(a)) from 1 to 25 cm(-1 )and reduced scattering coefficients ([Formula: see text]) from 5 to 25 cm(-1). These data and predictive models were used to estimate the optical properties of tissue-simulating phantoms. RESULTS: By comparing predicted and known optical properties, the average errors for ΞΌ(a )and [Formula: see text] were found to be 3.0% and 4.6%, respectively, for a linear probe approach. When bifurcated probe data was included and samples with ΞΌ(a )values less than 5 cm(-1 )were excluded, predictive errors for ΞΌ(a )and [Formula: see text] were further reduced to 1.8% and 3.5%. CONCLUSION: Improvements in system design have led to significant reductions in optical property estimation error. While the incorporation of a bifurcated illumination fiber shows promise for improving the accuracy of [Formula: see text] estimates, further study of this approach is needed to elucidate the source of discrepancies between measurements and simulation results at low ΞΌ(a )values

    3D finite compartment modeling of formation and healing of bruises may identify methods for age determination of bruises

    Get PDF
    Simulating the spatial and temporal behavior of bruises may identify methods that allow accurate age determination of bruises to assess child abuse. We developed a numerical 3D model to simulate the spatial kinetics of hemoglobin and bilirubin during the formation and healing of bruises. Using this model, we studied how skin thickness, bruise diameter and diffusivities affect the formation and healing of circular symmetric bruises and compared a simulated bruise with a natural inhomogeneous bruise. Healing is faster for smaller bruises in thinner and less dense skin. The simulated and natural bruises showed similar spatial and temporal dynamics. The different spatio-temporal dynamics of hemoglobin and bilirubin allows age determination of model bruises. Combining our model predictions with individual natural bruises may allow optimizing our model parameters. It may particularly identify methods for more accurate age determination than currently possible to aid the assessment of child abuse

    Familial hematuria

    Get PDF
    Hematuria is a common presenting complaint in pediatric nephrology clinics and often has a familial basis. This teaching article provides an overview of causes, diagnosis, and management of the major forms of familial hematuria, Alport syndrome, and thin basement membrane nephropathy

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pTβ‰₯20 GeV and pseudorapidities {pipe}Ξ·{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}Ξ·{pipe}<0. 8) for jets with 60≀pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≀{pipe}Ξ·{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. Β© 2013 CERN for the benefit of the ATLAS collaboration
    • …
    corecore