    Improved interchangeability with different corneal specular microscopes for quantitative endothelial cell analysis

    Get PDF
    Introduction: During our clinical practice and research, we encountered an interchangeability problem when using the SP-2000P and SP-3000P TopCon corneal specular microscopes (CSMs) (TopCon Medical Systems, Tokyo, Japan) regarding the endothelial cell count (ECC). We describe a method to improve interchangeability between these CSMs. Methods: Five consecutive good-quality endothelial cell photographs were obtained in 22 eyes of 11 subjects. An ECC comparison between the two CSMs was performed after (I) gauging and calibration by the manufacturer, (II) adjustment of the magnification, (III) correction after external horizontal and vertical calibration. Results: There was a statistically significant difference between the ECC of the SP-2000P and SP-3000P at the start. The SP-2000P counted an average of 500 cells/mm2 more than the SP-3000P (p=0.00). After correction for magnification and determining a correction factor based on external calibration, the difference between the ECC of the SP-2000P and the SP-3000P was then found to be 0.4 cells/mm2 and was not statistically significant (p=0.98). Discussion: We propose a method for improving interchangeability, which involves checking magnification settings, re-checking magnification calibration with external calibration devices, and then calculating correction factors. This method can be applied to various specular or confocal microscopes and their associated endothelial cell analysis software packages to be able to keep performing precise endothelial cell counts and to enable comparison of ECCs when a CSM needs to be replaced or when results from different microscopes need to be compared

    The rising incidence of Acanthamoeba keratitis: A 7-year nationwide survey and clinical assessment of risk factors and functional outcomes

    Get PDF
    textabstractPurpose To evaluate the incidence of Acanthamoeba keratitis in the Netherlands between 2009 and 2015 and to analyse predicting factors for treatment outcome. Methods Patient characteristics, diagnostic methods, diagnostic delay, therapy prior to and after diagnosis, and visual outcome were obtained from medical files of all patients diagnosed with Acanthamoeba keratitis in the Netherlands between 2009 and 2015. A logistic regression analysis on treatment failure, defined as a best corrected visual acuity of less than 20/40 Snellen decimals (i.e. >0.3 logMAR or an approximate loss of three lines of visual acuity) and/or the need for keratoplasty, was performed to determine predicting factors. Results Two hundred and twenty-four eyes of 224 patients were included. Ninety-five percent of the patients were contact lens wearers, of whom 74% wore soft contact lenses. The number of cases increased from 16 in 2009 to 49 in 2015. This resulted in an estimated incidence of 1 in 21,000 for soft contact lens wearers in 2015. Eighty-seven eyes (39%) met the criteria for treatment failure. In a multivariable regression analysis, higher age at presentation, a higher severity stage and corticosteroid use before diagnosis were positively correlated with treatment failure. Early referral to a cornea specialist was associated with better clinical outcomes
    corecore