139 research outputs found

    Severity parameter and global importance factor of non-newtonian models in 3D reconstructed human left coronary artery

    Get PDF
    This paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.The capabilities and limitations of various molecular viscosity models, when testing Left Coronary Artery (LCA) tree, were analyzed via: molecular viscosity, local and global non-Newtonian importance factors, Wall Shear Stress (WSS) and Wall Shear Stress Gradient (WSSG). Seven non-Newtonian molecular viscosity models, plus the Newtonian one, were compared. Dense grid of 620000 nodes located, mostly, at near to low WSS flow regions (endothelium regions) is needed for current LCA application. The WSS distribution yields a consistent LCA pattern for nearly all non-Newtonian models. High molecular viscosity, low WSS low WSSG values appear at proximal LCA regions at the outer walls of the major bifurcation. The global importance factor for the non-Newtonian power law model yields 76.7% (non-Newtonian flow), while for the Generalized power law model this value is 6.1% (Newtonian flow). The capabilities of the applied non-Newtonian law models appear at low strain rates. The Newtonian blood flow treatment is considered to be a good approximation at mid-and high-strain rates. In general, the non-Newtonian power law and the Generalized power law blood viscosity models are considered to approximate the molecular viscosity and WSS calculations in a more satisfactory way

    Computer-Aided Patient-Specific Coronary Artery Graft Design Improvements Using CFD Coupled Shape Optimizer

    Get PDF
    This study aims to (i) demonstrate the efficacy of a new surgical planning framework for complex cardiovascular reconstructions, (ii) develop a computational fluid dynamics (CFD) coupled multi-dimensional shape optimization method to aid patient-specific coronary artery by-pass graft (CABG) design and, (iii) compare the hemodynamic efficiency of the sequential CABG, i.e., raising a daughter parallel branch from the parent CABG in patient-specific 3D settings. Hemodynamic efficiency of patient-specific complete revascularization scenarios for right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX) bypasses were investigated in comparison to the stenosis condition. Multivariate 2D constraint optimization was applied on the left internal mammary artery (LIMA) graft, which was parameterized based on actual surgical settings extracted from 2D CT slices. The objective function was set to minimize the local variation of wall shear stress (WSS) and other hemodynamic indices (energy dissipation, flow deviation angle, average WSS, and vorticity) that correlate with performance of the graft and risk of re-stenosis at the anastomosis zone. Once the optimized 2D graft shape was obtained, it was translated to 3D using an in-house “sketch-based” interactive anatomical editing tool. The final graft design was evaluated using an experimentally validated second-order non-Newtonian CFD solver incorporating resistance based outlet boundary conditions. 3D patient-specific simulations for the healthy coronary anatomy produced realistic coronary flows. All revascularization techniques restored coronary perfusions to the healthy baseline. Multi-scale evaluation of the optimized LIMA graft enabled significant wall shear stress gradient (WSSG) relief (~34%). In comparison to original LIMA graft, sequential graft also lowered the WSSG by 15% proximal to LAD and diagonal bifurcation. The proposed sketch-based surgical planning paradigm evaluated the selected coronary bypass surgery procedures based on acute hemodynamic readjustments of aorta-CA flow. This methodology may provide a rational to aid surgical decision making in time-critical, patient-specific CA bypass operations before in vivo execution

    Elevated levels of endothelial-derived microparticles, and serum CXCL9 and SCGF-β are associated with unstable asymptomatic carotid plaques.

    Get PDF
    Endothelial microparticles (EMPs) are released from dysfunctional endothelial cells. We hypothesised that patients with unstable carotid plaque have higher levels of circulating microparticles compared to patients with stable plaques, and may correlate with serum markers of plaque instability and inflammation. Circulating EMPs, platelet MPs (PMPs) and inflammatory markers were measured in healthy controls and patients undergoing carotid endarterectomy. EMP/PMPs were quantified using flow cytometry. Bioplex assays profiled systemic inflammatory and bone-related proteins. Immunohistological analysis detailed the contribution of differentially-regulated systemic markers to plaque pathology. Alizarin red staining showed calcification. EMPs and PMPs were significantly higher in patients with carotid stenosis (≥70%) compared to controls, with no differences between asymptomatic vs symptomatic patients. Asymptomatic patients with unstable plaques exhibited higher levels of EMPs, CXCL9 and SCGF-β compared to those with stable plaques. CXCL9, and SCGF-β were detected within all plaques, suggesting a contribution to both localised and systemic inflammation. Osteopontin and osteoprotegerin were significantly elevated in the symptomatic vs asymptomatic group, while osteocalcin was higher in asymptomatic patients with stable plaque. All plaques exhibited calcification, which was significantly greater in asymptomatic patients. This may impact on plaque stability. These data could be important in identifying patients at most benefit from intervention

    Focus on the research utility of intravascular ultrasound - comparison with other invasive modalities

    Get PDF
    Intravascular ultrasound (IVUS) is an invasive modality which provides cross-sectional images of a coronary artery. In these images both the lumen and outer vessel wall can be identified and accurate estimations of their dimensions and of the plaque burden can be obtained. In addition, further processing of the IVUS backscatter signal helps in the characterization of the type of the plaque and thus it has been used to study the natural history of the atherosclerotic evolution. On the other hand its indigenous limitations do not allow IVUS to assess accurately stent struts coverage, existence of thrombus or exact site of plaque rupture and to identify some of the features associated with increased plaque vulnerability. In order this information to be obtained, other modalities such as optical coherence tomography, angioscopy, near infrared spectroscopy and intravascular magnetic resonance imaging have either been utilized or are under evaluation. The aim of this review article is to present the current utilities of IVUS in research and to discuss its advantages and disadvantages over the other imaging techniques

    The organelle of differentiation in embryos: the cell state splitter

    Full text link
    corecore