216 research outputs found
Peristaltic Pumping of Blood Through Small Vessels of Varying Cross-section
The paper is devoted to a study of the peristaltic motion of blood in the
micro-circulatory system. The vessel is considered to be of varying
cross-section. The progressive peristaltic waves are taken to be of sinusoidal
nature. Blood is considered to be a Herschel-Bulkley fluid. Of particular
concern here is to investigate the effects of amplitude ratio, mean pressure
gradient, yield stress and the power law index on the velocity distribution,
streamline pattern and wall shear stress. On the basis of the derived
analytical expression, extensive numerical calculations have been made. The
study reveals that velocity of blood and wall shear stress are appreciably
affected due to the non-uniform geometry of blood vessels. They are also highly
sensitive to the magnitude of the amplitude ratio and the value of the fluid
index.Comment: Accepted for publication in ASME journal of Applied Mechanics. arXiv
admin note: text overlap with arXiv:1108.1285v
Non-Newtonian characteristics of peristaltic flow of blood in micro-vessels
Of concern in the paper is a generalized theoretical study of the
non-Newtonian characteristics of peristaltic flow of blood through
micro-vessels, e.g. arterioles. The vessel is considered to be of variable
cross-section and blood to be a Herschel-Bulkley type of fluid. The progressive
wave front of the peristaltic flow is supposed sinusoidal/straight section
dominated (SSD) (expansion/contraction type); Reynolds number is considered to
be small with reference to blood flow in the micro-circulatory system. The
equations that govern the non-Newtonian peristaltic flow of blood are
considered to be non-linear. The objective of the study has been to examine the
effect of amplitude ratio, mean pressure gradient, yield stress and the power
law index on the velocity distribution, wall shear stress, streamline pattern
and trapping. It is observed that the numerical estimates for the aforesaid
quantities in the case of peristaltic transport of the blood in a channel are
much different from those for flow in an axisymmetric vessel of circular
cross-section. The study further shows that peristaltic pumping, flow velocity
and wall shear stress are significantly altered due to the non-uniformity of
the cross-sectional radius of blood vessels of the micro-circulatory system.
Moreover, the magnitude of the amplitude ratio and the value of the fluid index
are important parameters that affect the flow behaviour. Novel features of SSD
wave propagation that affect the flow behaviour of blood have also been
discussed.Comment: Accepted for publication in Communications in Nonlinear Science and
Numerical Simulation, Elsevier. arXiv admin note: text overlap with
arXiv:1006.017
Slip and hall current effects on Jeffrey fluid suspension flow in a peristaltic hydromagnetic blood micropump
The magnetic properties of blood allow it to be manipulated with an electromagnetic field. Electromagnetic blood flow pumps are a robust technology which provide more elegant and sustainable performance compared with conventional medical pumps. Blood is a complex multi-phase suspension with non-Newtonian characteristics which are significant in micro-scale transport. Motivated by such applications, in the present article a mathematical model is developed for magnetohydrodynamic (MHD) pumping of blood in a deformable channel with peristaltic waves. A Jeffery’s viscoelastic formulation is employed for the rheology of blood. A twophase fluid-particle (“dusty”) model is utilized to better simulate suspension characteristics (plasma and erythrocytes). Hall current and wall slip effects are incorporated to achieve more realistic representation of actual systems. A two-dimensional asymmetric channel with dissimilar peristaltic wave trains propagating along the walls is considered. The governing conservation equations for mass, fluid and particle momentum are formulated with appropriate boundary conditions. The model is simplified using of long wavelength and creeping flow approximations. The model is also transformed from the fixed frame to the wave frame and rendered non-dimensional. Analytical solutions are derived. The resulting boundary value problem is solved analytically and exact expressions are derived for the fluid velocity, particulate velocity, fluid/particle fluid and particulate volumetric flow rates, axial pressure gradient, pressure rise and skin friction distributions are evaluated in detail. Increasing Hall current parameter reduces bolus growth in the channel, particle phase velocity and pressure difference in the augmented pumping region whereas it increases fluid phase velocity, axial pressure gradient and pressure difference in the pumping region. Increasing the hydrodynamic slip parameter accelerates both particulate and fluid phase flow at and close to the channel walls, enhances wall skin friction, boosts pressure difference in the augmented pumping region and increases bolus magnitudes. Increasing viscoelastic parameter (stress relaxation time to retardation time ratio) decelerates the fluid phase flow, accelerates the particle phase flow, decreases axial pressure gradient, elevates pressure difference in the augmented pumping region and reduces pressure difference in the pumping region. Increasing drag particulate suspension parameter decelerates the particle phase velocity, accelerates the fluid phase velocity, strongly elevates axial pressure gradient and reduces pressure difference (across one wavelength) in the augmented pumping region. Increasing particulate volume fraction density enhances bolus magnitudes in both the upper and lower zones of the channel and elevates pressure rise in the augmented pumping region
A next generation, pilot-scale continuous sterilization system for fermentation media
A new continuous sterilization system was designed, constructed, started up, and qualified for media sterilization for secondary metabolite cultivations, bioconversions, and enzyme production. An existing Honeywell Total Distributed Control 3000-based control system was extended using redundant High performance Process Manager controllers for 98 I/O (input/output) points. This new equipment was retrofitted into an industrial research fermentation pilot plant, designed and constructed in the early 1980s. Design strategies of this new continuous sterilizer system and the expanded control system are described and compared with the literature (including dairy and bio-waste inactivation applications) and the weaknesses of the prior installation for expected effectiveness. In addition, the reasoning behind selection of some of these improved features has been incorporated. Examples of enhancements adopted include sanitary heat exchanger (HEX) design, incorporation of a “flash” cooling HEX, on-line calculation of F(o) and R(o), and use of field I/O modules located near the vessel to permit low-cost addition of new instrumentation. Sterilizer performance also was characterized over the expected range of operating conditions. Differences between design and observed temperature, pressure, and other profiles were quantified and investigated
Granular Assembly of α-Synuclein Leading to the Accelerated Amyloid Fibril Formation with Shear Stress
α-Synuclein participates in the Lewy body formation of Parkinson's disease. Elucidation of the underlying molecular mechanism of the amyloid fibril formation is crucial not only to develop a controlling strategy toward the disease, but also to apply the protein fibrils for future biotechnology. Discernable homogeneous granules of α-synuclein composed of approximately 11 monomers in average were isolated in the middle of a lag phase during the in vitro fibrillation process. They were demonstrated to experience almost instantaneous fibrillation during a single 12-min centrifugal membrane-filtration at 14,000×g. The granular assembly leading to the drastically accelerated fibril formation was demonstrated to be a result of the physical influence of shear force imposed on the preformed granular structures by either centrifugal filtration or rheometer. Structural rearrangement of the preformed oligomomeric structures is attributable for the suprastructure formation in which the granules act as a growing unit for the fibril formation. To parallel the prevailing notion of nucleation-dependent amyloidosis, we propose a double-concerted fibrillation model as one of the mechanisms to explain the in vitro fibrillation of α-synuclein, in which two consecutive concerted associations of monomers and subsequent oligomeric granular species are responsible for the eventual amyloid fibril formation
- …