2,489 research outputs found

    Effects of depolarizing quantum channels on BB84 and SARG04 quantum cryptography protocols

    Full text link
    We report experimental studies on the effect of the depolarizing quantum channel on weak-pulse BB84 and SARG04 quantum cryptography. The experimental results show that, in real world conditions in which channel depolarization cannot be ignored, BB84 should perform better than SARG04.Comment: 4 pages, 4 figure

    Application of PEEP using the i-gel during volume-controlled ventilation in anesthetized, paralyzed patients

    Get PDF
    PURPOSE: This prospective, randomized trial was designed to assess whether the i-gel supraglottic airway device is suitable for volume-controlled ventilation while applying positive end-expiratory pressure (PEEP) of 5 cmH(2)O under general anesthesia. It was believed that this device might improve arterial oxygenation. METHODS: Forty adult patients (aged 20–60 years) scheduled for elective orthopedic surgery were enrolled in this study. Twenty patients were ventilated without external PEEP [zero positive end-expiratory pressure (ZEEP) group], and the other 20 were ventilated with PEEP 5 cmH(2)O (PEEP group) after placing an i-gel device. Volume-controlled ventilation at a tidal volume (TV) of 8 ml/kg of ideal body weight, leak volume, and arterial blood gas analysis were investigated. RESULTS: The incidences of a significant leak were similar in the ZEEP and PEEP groups (3/20 and 1/20, respectively; P = 0.605), as were leak volumes. No significant PaO(2) difference was observed between the two groups at 1 h after satisfactory i-gel insertion (215 ± 38 vs. 222 ± 54; P = 0.502). CONCLUSIONS: The use of an i-gel during PEEP application at 5 cmH(2)O did not increase the incidence of a significant air leak, and a PEEP of 5 cmH(2)O failed to improve arterial oxygenation during controlled ventilation in healthy adult patients

    Impact of Toxocariasis in Patients with Unexplained Patchy Pulmonary Infiltrate in Korea

    Get PDF
    Toxocariasis is one of the causes of pulmonary eosinophilic infiltrate that is increasing in Korea. This study was designed to identify the prevalence of toxocara seropositivity in patients with unexplained pulmonary patchy infiltrate and to evaluate associated factors. We evaluated 102 patients with unexplained pulmonary patchy infiltrate on chest computed tomography (CT) scan. As a control set, 116 subjects with normal chest CT were also evaluated. History of allergic disease, drug use, parasitic disease and raw cow liver intake were taken. Blood eosinophil count and total IgE level were measured. Specific serum IgG antibody to Toxocara canis larval antigen and specific IgG antibodies to 4 other parasites were measured by enzyme-linked immunosorbent assay (ELISA). In the infiltrate group, 66.7% subjects were toxocara seropositive whereas 22.4% of the control group were seropositive (p<0.001). In the infiltrate group, patients with a history of eating raw cow liver (odds ratio [OR], 7.8) and patients with eosinophilia (OR, 5.2) had a higher incidence of toxocara seropositivity. Thirty-five percent of toxocara seropositive patients with infiltrate exhibited migrating infiltrate and 48% had decreased infiltrate on the follow-up CT. We recommend that toxocara ELISA should be performed in patients with unexplained pulmonary patchy infiltrate, and that the eating of raw cow liver should be actively discouraged

    Blockchain and AI Meet in the Metaverse

    Get PDF
    With new technologies related to the development of computers, graphics, and hardware, the virtual world has become a reality. As COVID-19 spreads around the world, the demand for virtual reality increases, and the industry represented by the Metaverse is developing. In the Metaverse, a virtual world that transcends reality, artificial intelligence and blockchain technology are being combined. This chapter explains how artificial intelligence and blockchain can affect the Metaverse

    Characteristics of thyroid nodules in infant with congenital hypothyroidism

    Get PDF
    PurposeThis study aimed to assess the characteristics of thyroid nodules among infants diagnosed with congenital hypothyroidism.MethodsA retrospective study of 660 infants (374 males, 286 females) diagnosed with congenital hypothyroidism was carried out at the Pediatric Endocrine Clinic in Soonchunhyang University Hospital, Korea, between May 2003 and February 2013. The average age at diagnosis was 1.16±1.68 months.ResultsOf the 28 patients (4.2%) with thyroid nodules, 17 (2.6%) had cystic thyroid nodules and 11 (1.6%) had solid thyroid nodules. There were no significant differences in gender or age between congenital hypothyroidism patients who hadthyroid nodules and those who did not. All nodules were asymptomatic. The average age at diagnosis of congenital hypothyroidism with nodules was 1.42±1.39 months. All detected nodules measured less than 1 cm in diameter. Twenty-two of the 28 infants (78.6%) had only one nodule, while multiple nodules were found in 6 infants (21.4%). Of the 28 infants diagnosed with nodules, 16 underwent thyroid ultrasonography during follow-up and 8 of them (50%) showed no signs of nodules at thyroid ultrasonography.ConclusionThe prevalence of thyroid nodules in infants with congenital hypothyroidism was 4.2%. Most thyroid nodules were small in size and benign, disappearing during follow-up observation. We therefore conclude that thyroid nodules in infants with congenital hypothyroidism can simply be observed and do not require direct treatment

    Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices

    Get PDF
    Background Precise measurement of ocular biometry is critical for determining intraocular lens power. Newly developed swept-source optical coherence tomography (SS-OCT) - based ocular biometric devices, ANTERION and CASIA2 provide ocular biometric measurements as IOLMaster 700. This study aimed to assess agreement between three devices. Methods This retrospective comparative study includes patients with cataract who underwent ocular biometric measurements with three devices, ANTERION, CASIA2, and IOLMaster 700, at Seoul National University Hospital, in April 2020. Anterior keratometry, total keratometry, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were the main parameters for the comparison. To assess the agreement between the devices, intraclass coefficient (ICC) and Bland-Altman analysis with 95% limits of agreement (LoA) were used. Results A total of 47 eyes of 29 patients were measured with three devices. Average anterior keratometry showed excellent agreement (ICC ≥ 0.989), and the mean difference was less than 0.1 D. However, the ICC of the total average keratometry ranged from 0.808 to 0.952, and the difference was more than 0.43 D. The AL measured by ANTERION and IOLMaster 700 showed excellent agreement (ICC = 0.999), and the mean difference was 0.005 mm. The ANTERION and IOLMaster 700 did not obtain AL in six (12.8%) and three (6.4%) cases, respectively (P = 0.001 by Fishers exact test). The CCT, ACD, and LT also showed excellent agreement (ICC > 0.9). Conclusions The new SS-OCT-based devices, ANTERION, and CASIA2 showed a good agreement with IOLMaster 700 in measuring ocular biometry except for the total keratometry. The AL of ANTERION and IOLMaster 700 showed excellent agreement
    corecore