69 research outputs found

    Search for supersymmetry with a dominant R-parity violating LQDbar couplings in e+e- collisions at centre-of-mass energies of 130GeV to 172 GeV

    Full text link
    A search for pair-production of supersymmetric particles under the assumption that R-parity is violated via a dominant LQDbar coupling has been performed using the data collected by ALEPH at centre-of-mass energies of 130-172 GeV. The observed candidate events in the data are in agreement with the Standard Model expectation. This result is translated into lower limits on the masses of charginos, neutralinos, sleptons, sneutrinos and squarks. For instance, for m_0=500 GeV/c^2 and tan(beta)=sqrt(2) charginos with masses smaller than 81 GeV/c^2 and neutralinos with masses smaller than 29 GeV/c^2 are excluded at the 95% confidence level for any generation structure of the LQDbar coupling.Comment: 32 pages, 30 figure

    A philosophical analysis of the evidence-based medicine debate

    Get PDF
    BACKGROUND: The term "evidence-based medicine" (or EBM) was introduced about ten years ago, and there has been considerable debate about the value of EBM. However, this debate has sometimes been obscured by a lack of conceptual clarity concerning the nature and status of EBM. DISCUSSION: First, we note that EBM proponents have obscured the current debate by defining EBM in an overly broad, indeed almost vacuous, manner; we offer a clearer account of EBM and its relation to the alternative approaches to medicine. Second, while EBM proponents commonly cite the philosophical work of Thomas Kuhn and claim that EBM is a Kuhnian 'paradigm shift,' we argue that such claims are seriously mistaken and unduly polarize the EBM debate. Third, we suggest that it is much more fruitful to understand the relationship between EBM and its alternatives in light of a different philosophical metaphor: W.V. Quine's metaphor of the web of belief. Seen in this way, we argue that EBM is an approach to medical practice that is indeed importantly different from the alternatives. SUMMARY: We can have a more productive debate about the value of EBM by being clearer about the nature of EBM and its relationship to alternative approaches to medicine

    The global atmospheric electrical circuit and climate

    Get PDF
    Evidence is emerging for physical links among clouds, global temperatures, the global atmospheric electrical circuit and cosmic ray ionisation. The global circuit extends throughout the atmosphere from the planetary surface to the lower layers of the ionosphere. Cosmic rays are the principal source of atmospheric ions away from the continental boundary layer: the ions formed permit a vertical conduction current to flow in the fair weather part of the global circuit. Through the (inverse) solar modulation of cosmic rays, the resulting columnar ionisation changes may allow the global circuit to convey a solar influence to meteorological phenomena of the lower atmosphere. Electrical effects on non-thunderstorm clouds have been proposed to occur via the ion-assisted formation of ultra-fine aerosol, which can grow to sizes able to act as cloud condensation nuclei, or through the increased ice nucleation capability of charged aerosols. Even small atmospheric electrical modulations on the aerosol size distribution can affect cloud properties and modify the radiative balance of the atmosphere, through changes communicated globally by the atmospheric electrical circuit. Despite a long history of work in related areas of geophysics, the direct and inverse relationships between the global circuit and global climate remain largely quantitatively unexplored. From reviewing atmospheric electrical measurements made over two centuries and possible paleoclimate proxies, global atmospheric electrical circuit variability should be expected on many timescale

    "Quantal" Ca2+ release at the cytoplasmic aspect of the Ins(1,4,5)P3R channel in smooth muscle

    No full text
    Smooth muscle responds to activation of the inositol (1,4,5)-trisphosphate receptor [Ins(1,4,5)P3R] with a graded concentration-dependent ('quantal') Ca2+ release from the sarcoplasmic reticulum (SR) store. Graded release seems incompatible both with the finite capacity of the store and the Ca2+-induced Ca2+ release (CICR)-like facility, at Ins(1,4,5)P3Rs, that, once activated, should release the entire content of SR Ca2+. The structural organization of the SR and the regulation of Ins(1,4,5)P3R activity by inositol (1,4,5)-trisphosphate [Ins(1,4,5)P3] and Ca2+ have each been proposed to explain 'quantal' Ca2+ release. Here, we propose that regulation of Ins(1,4,5)P3R activity by lumenal Ca2+ acting at the cytoplasmic aspect of the receptor might explain 'quantal' Ca2+ release in smooth muscle. The entire SR store was found to be lumenally continuous and Ca2+ could diffuse freely throughout: peculiarities of SR structure are unlikely to account for 'quantal' release. While Ca2+ release was regulated by [Ca2+] within the SR, the velocity of release increased (accelerated) during the release process. The extent of acceleration of release determined the peak cytoplasmic [Ca2+] and was attenuated by a reduction in SR [Ca2+] or an increase in cytoplasmic Ca2+ buffering. Positive feedback by released Ca2+ acting at the cytoplasmic aspect of Ins(1,4,5)P3Rs (i.e. CICR-like) might (a) account for the acceleration, (b) provide the regulation of release by SR [Ca2+] and (c) explain the 'quantal' release process itself. During Ca2+ release, SR [Ca2+] and thus unitary Ins(1,4,5)P3R currents decline, CICR reduces and stops. With increasing [Ins(1,4,5)P3], coincidental activation of several neighbouring Ins(1,4,5)P3Rs offsets the reduced Ins(1,4,5)P3R current to renew CICR and Ca2+ release

    Particle size effects on ice crystal accretion - Part II

    No full text
    This paper describes ongoing research intended to simulate ice accretion in an inter-compressor duct bleed slot resulting from the ingestion of altitude ice crystals. The authors have previously shown that ice crystal particle size plays an important role in the ice crystal accretion phenomenon. It was also shown that ice crystal particle size affects the degree of natural melt that occurs for a given aerodynamic condition. The data presented herein decouples the effects of ice particle melt and particle size distribution to generate accretions with the same ratio of freestream liquid-to-total water fraction. The effects of wet bulb temperature and ice particle size on the natural melting of ice crystals are discussed. An ice preservation procedure is followed to allow tracings of the accretion to be taken along the test article. Ice crystal particle size distribution is characterized using a shadowgraphy imaging technique. Finally, the reduction in accretion rate relative to the theoretical maximum rate of surface accretion by ice crystal particles is discussed. The test article simulates a forward facing, inclined endwall bleed slot in a gas turbine compressor as a simplified two-dimensional representation. The geometry, having a surface inclined 20\ub0 to the incoming flow, proved to be susceptible to mixed phase ice crystal accretion. Particle size and particularly the large particle tail of the distribution had a significant impact on the magnitude of accretion under mixed phase test conditions for wet bulb temperatures above and below 0\ub0C. The leading edge growth rates were found to be 1/4 to 1/9 of the theoretical growth rate suggesting that erosion, splashing, particle bounce and other loss mechanism rates are significant. The ice tracings were used to estimate an accretion mass for a hypothetical large bypass ratio gas turbine. It was found that approximately 4kg of ice could be generated should the inter-compressor duct be exposed to the conditions tested for 5 minutes. \ua9 2013 by Her Majesty the Queen in Right of Canada. Published by the American Institute of Aeronautics and Astronautics.Peer reviewed: YesNRC publication: Ye
    • …
    corecore