152 research outputs found

    Effect of combined water drinking test and dark room provocative testing in Caucasian eyes with narrow angles

    Get PDF
    Purpose: To assess the usefulness of water drinking test and dark room provocative testing (WDT + DRPT) in current clinical practice by evaluating input parameters from Swept-source Optical Coherence Tomography (SS-OCT) images, and to determine if clinical factors like axial length, central endothelial cell count (CECC) and retinal nerve fibre layer thickness (RNFL) thickness are associated with a positive WDT + DRPT. Methods: SS-OCT examination was performed in consecutive subjects presenting as new patients in the outpatient clinic aged > 40 years. If at least one eye met the inclusion criteria (anterior chamber angles <20° and anterior chamber depth < 2.5 mm on SS-OCT), subjects were included in this study and WDT + DRPT was carried out. The eye with the smallest angle was analysed. The difference in parameters between eyes with a positive (≥8 mmHg) and negative (<8 mmHg) increase in intraocular pressure (IOP) after WDT + DRPT were statistically analysed. Second, the correlation between IOP increase after WDT + DRPT and anterior chamber angle parameters (RNFL thickness, CECC and axial length) was studied. Results: A total of 95 subjects with a mean age of 64 years were included. There was an association between IOP increase after WDT + DRPT and anterior chamber angle characteristics, however this was not of clinical significance. No positive results after WDT + DRPT were found in patients with anterior chamber angles ≥ 20°. Conclusions: The present findings indicate that this combined provocative test has no definite correlative or predictive value in angle closure disease. Further, the test is not useful in predicting early diagnosis or possible CECC or RNFL loss

    Retinal vascular tortuosity in schizophrenia and bipolar disorder

    Get PDF
    \u3cp\u3eThe micro-vasculature of retina and brain share common morphological, physiological, and pathological properties. Retina being easily accessible, retinal vascular examination provides an indirect assessment of cerebral vasculature. Considering the high prevalence of vascular morbidity in SCZ and BD a few studies have examined retinal vascular caliber and have reported increased retinal venular caliber in schizophrenia (SCZ). Retinal vascular tortuosity could serve as a better structural measure than caliber as it is static and less susceptible to pulse period variations. However, to date, no study has examined retinal vascular tortuosity in SCZ and bipolar disorder (BD). Hence, we examined retinal vascular tortuosity in comparison with healthy volunteers (HV). We included 255 subjects (78 HV, 79 SCZ, and 86 BD) in the age range of 18 to 50 years. Trained personnel acquired images using a non-mydriatic fundus camera. To measure the average retinal arteriolar tortuosity index (RATI) and retinal venular tortuosity index (RVTI), we used a previously validated, semi-automatic algorithm. The results showed significant differences across the three groups in RATI but not in RVTI; both BD and SCZ had significantly increased RATI compared to HV. There was also a significant difference between SCZ and BD, with BD having higher RATI. If shown to be of predictive utility in future longitudinal studies, it has the potential to identify patients at risk of development of adverse vascular events. As retinal vascular imaging is non-invasive and inexpensive, it could serve as a proxy marker and window to cerebral vasculature.\u3c/p\u3

    Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation

    Get PDF
    Contains fulltext : 81835.pdf (Publisher’s version ) (Open Access)BACKGROUND: The repeatability and interchangeability of imaging devices measuring central corneal thickness (CCT) and anterior chamber depth (ACD) are important in the assessment of patients considering refractive surgery. The purpose of this study was to investigate the agreement of CCT and ACD measurements using three imaging technologies in healthy eyes and in eyes after phakic intraocular lens implantation (pIOL). METHODS: In this comparative study, CCT and ACD were measured using anterior segment optical coherence tomography (AS-OCT), Orbscan II, and Pentacam in 33 healthy volunteers (66 eyes) and 22 patients (42 eyes) after pIOL implantation. Intraobserver repeatability was evaluated for all three devices in the healthy volunteer group. RESULTS: Pairwise comparison of CCT measurements showed significant differences between all devices (P < 0.001), except for the AS-OCT and Orbscan II in the healthy volunteer group (P = 0.422) and the Orbscan II and Pentacam in the pIOL group (P = 0.214). ACD measurements demonstrated significant differences between all pairwise comparisons in both groups (P < or = 0.001). Intraobserver reliability was high for CCT and ACD measurements in the healthy volunteer group, with coefficients of variation ranging from 0.6% to 1.2% and 0.4% to 0.5% respectively. CONCLUSIONS: CCT and ACD measurements using AS-OCT, Orbscan II, and Pentacam demonstrated high intraobserver reliability. However, these devices should not be used interchangeably for measurements of CCT and ACD in healthy subject and patients after pIOL implantation

    Blood pressure variability and microvascular dysfunction:the Maastricht Study

    Get PDF
    Background: Microvascular dysfunction (MVD) contributes to stroke, dementia, depression, retinopathy and chronic kidney disease. However, the determinants of MVD are incompletely understood. Greater blood pressure variability (BPV) may be one such determinant. Methods and results: We used cross-sectional data of The Maastricht Study (n = 2773, age 59.9 years; 51.9% men) to investigate whether greater very short- to mid-term BPV is associated with various MVD measures. We standardized and averaged within-visit, 24-h and 7-day BPV into a systolic and a diastolic BPV composite score. MVD measures included a composite score of MRI cerebral small vessel disease (CSVD) features (total brain parenchymal volume, white matter hyperintensity volume, lacunar infarcts and cerebral microbleeds), a composite score of flicker light-induced retinal arteriolar and venular dilation response, albuminuria, heat-induced skin hyperemia and a composite score of plasma biomarkers of MVD (sICAM-1, sVCAM-1, sE-selectin and von Willebrand Factor). We used linear regression adjusted for age, sex, glucose metabolism status, mean 24-h systolic or DBP, cardiovascular risk factors and antihypertensive medication. We found that higher systolic and diastolic BPV composite scores (per SD) were associated with higher albuminuria [higher ratio, 1.04 (95% CI 1.00–1.08) and 1.07 (1.03–1.11), respectively], but not with other measures of MVD tested. Conclusion: Greater systolic and diastolic BPV was associated with higher albuminuria, but not with CSVD features, flicker light-induced retinal arteriolar and venular dilation response, heat-induced skin hyperemia and plasma biomarkers of MVD. This suggests that the microvasculature of the kidneys is most vulnerable to the detrimental effects of greater BPV

    Mitochondrial DNA D-loop variants correlate with a primary open-angle glaucoma subgroup

    Get PDF
    IntroductionPrimary open-angle glaucoma (POAG) is a characteristic optic neuropathy, caused by degeneration of the optic nerve-forming neurons, the retinal ganglion cells (RGCs). High intraocular pressure (IOP) and aging have been identified as major risk factors; yet the POAG pathophysiology is not fully understood. Since RGCs have high energy requirements, mitochondrial dysfunction may put the survivability of RGCs at risk. We explored in buffy coat DNA whether mtDNA variants and their distribution throughout the mtDNA could be risk factors for POAG.MethodsThe mtDNA was sequenced from age- and sex-matched study groups, being high tension glaucoma (HTG, n=71), normal tension glaucoma patients (NTG, n=33), ocular hypertensive subjects (OH, n=7), and cataract controls (without glaucoma; n=30), all without remarkable comorbidities.ResultsNo association was found between the number of mtDNA variants in genes encoding proteins, tRNAs, rRNAs, and in non-coding regions in the different study groups. Next, variants that controls shared with the other groups were discarded. A significantly higher number of exclusive variants was observed in the D-loop region for the HTG group (~1.23 variants/subject), in contrast to controls (~0.35 variants/subject). In the D-loop, specifically in the 7S DNA sub-region within the Hypervariable region 1 (HV1), we found that 42% of the HTG and 27% of the NTG subjects presented variants, while this was only 14% for the controls and OH subjects. As we have previously reported a reduction in mtDNA copy number in HTG, we analysed if specific D-loop variants could explain this. While the majority of glaucoma patients with the exclusive D-loop variants m.72T&gt;C, m.16163 A&gt;G, m.16186C&gt;T, m.16298T&gt;C, and m.16390G&gt;A presented a mtDNA copy number below controls median, no significant association between these variants and low copy number was found and their possible negative role in mtDNA replication remains uncertain. Approximately 38% of the HTG patients with reduced copy number did not carry any exclusive D-loop or other mtDNA variants, which indicates that variants in nuclear-encoded mitochondrial genes, environmental factors, or aging might be involved in those cases.ConclusionIn conclusion, we found that variants in the D-loop region may be a risk factor in a subgroup of POAG, possibly by affecting mtDNA replication
    • …
    corecore