21 research outputs found
Internet of Food (IoF), Tailor-Made Metal Oxide Gas Sensors to Support Tea Supply Chain
Tea is the second most consumed beverage, and its aroma, determined by volatile compounds (VOCs) present in leaves or developed during the processing stages, has a great influence on the final quality. The goal of this study is to determine the volatilome of different types of tea to provide a competitive tool in terms of time and costs to recognize and enhance the quality of the product in the food chain. Analyzed samples are representative of the three major types of tea: black, green, and white. VOCs were studied in parallel with different technologies and methods: gas chromatography coupled with mass spectrometer and solid phase microextraction (SPME-GC-MS) and a device called small sensor system, (S3). S3 is made up of tailor-made metal oxide gas sensors, whose operating principle is based on the variation of sensor resistance based on volatiloma exposure. The data obtained were processed through multivariate statistics, showing the full file of the pre-established aim. From the results obtained, it is understood how supportive an innovative technology can be, remotely controllable supported by machine learning (IoF), aimed in the future at increasing food safety along the entire production chain, as an early warning system for possible microbiological or chemical contamination
Innovative Sensor Approach to Follow Campylobacter jejuni Development
Campylobacter spp infection affects more than 200,000 people every year in Europe and in the last four years a trend shows an increase in campylobacteriosis. The main vehicle for transmission of the bacterium is contaminated food like meat, milk, fruit and vegetables. In this study, the aim was to find characteristic volatile organic compounds (VOCs) of C. jejuni in order to detect its presence with an array of metal oxide (MOX) gas sensors. Using a starting concentration of 103 CFU/mL, VOCs were analyzed using Gas-Chromatography Mass-Spectrometry (GC-MS) with a Solid-Phase Micro Extraction (SPME) technique at the initial time (T0) and after 20 h (T20). It has been found that a Campylobacter sample at T20 is characterized by a higher number of alcohol compounds that the one at T0 and this is due to sugar fermentation. Sensor results showed the ability of the system to follow bacteria curve growth from T0 to T20 using Principal Component Analysis (PCA). In particular, this results in a decrease of ΔR/R0 value over time. For this reason, MOX sensors are a promising technology for the development of a rapid and sensitive system for C. jejuni
Real Time Monitoring of Wine Vinegar Supply Chain through MOX Sensors
Vinegar is a fermented product that is appreciated world-wide. It can be obtained from different kinds of matrices. Specifically, it is a solution of acetic acid produced by a two stage fermentation process. The first is an alcoholic fermentation, where the sugars are converted in ethanol and lower metabolites by the yeast action, generally Saccharomyces cerevisiae. This was performed through a technique that is expanding more and more, the so-called “pied de cuve”. The second step is an acetic fermentation where acetic acid bacteria (AAB) action causes the conversion of ethanol into acetic acid. Overall, the aim of this research is to follow wine vinegar production step by step through the volatiloma analysis by metal oxide semiconductor MOX sensors developed by Nano Sensor Systems S.r.l. This work is based on wine vinegar monitored from the grape must to the formed vinegar. The monitoring lasted 4 months and the analyses were carried out with a new generation of Electronic Nose (EN) engineered by Nano Sensor Systems S.r.l., called Small Sensor Systems Plus (S3+), equipped with an array of six gas MOX sensors with different sensing layers each. In particular, real-time monitoring made it possible to follow and to differentiate each step of the vinegar production. The principal component analysis (PCA) method was the statistical multivariate analysis utilized to process the dataset obtained from the sensors. A closer look to PCA graphs affirms how the sensors were able to cluster the production steps in a chronologically correct manner
Multidisciplinary Approach to Characterizing the Fingerprint of Italian EVOO
Extra virgin olive oil (EVOO) is characterized by its aroma and other sensory attributes. These are determined by the geographical origin of the oil, extraction process, place of cultivation, soil, tree varieties, and storage conditions. In the present work, an array of metal oxide gas sensors (called S3), in combination with the SPME-GC-MS technique, was applied to the discrimination of different types of olive oil (phase 1) and to the identification of four varieties of Garda PDO extra virgin olive oils coming from west and east shores of Lake Garda (phase 2). The chemical analysis method involving SPME-GC-MS provided a complete volatile component of the extra virgin olive oils that was used to relate to the S3 multisensory responses. Furthermore, principal component analysis (PCA) and k-Nearest Neighbors (k-NN) analysis were carried out on the set of data acquired from the sensor array to determine the best sensors for these tasks and to assess the capability of the system to identify various olive oil samples. k-NN classification rates were found to be 94.3% and 94.7% in the two phases, respectively. These first results are encouraging and show a good capability of the S3 instrument to distinguish different oil samples
A New Kind of Chemical Nanosensors for Discrimination of Espresso Coffee
There are different methods to extract and brew coffee, therefore, coffee processing is an important factor and should be studied in detail. Herein, coffee was brewed by means of a new espresso professional coffee machine, using coffee powder or portioned coffee (capsule). Four different kinds of coffees (Biologico, Dolce, Deciso, Guatemala) were investigated with and without capsules and the goal was to classify the volatiloma of each one by Small Sensor System (S3). The response of the semiconductor metal oxide sensors (MOX) of S3 where recorded, for all 288 replicates and after normalization âR/R0 was extracted as a feature. PCA analysis was used to compare and differentiate the same kind of coffee sample with and without a capsule. It could be concluded that the coffee capsules affect the quality, changing on the flavor profile of espresso coffee when extracted different methods confirming the use of s3 device as a rapid and user-friendly tool in the food quality control chain
A New Kind of Chemical Nanosensors for Discrimination of Espresso Coffee
There are different methods to extract and brew coffee, therefore, coffee processing is an important factor and should be studied in detail. Herein, coffee was brewed by means of a new espresso professional coffee machine, using coffee powder or portioned coffee (capsule). Four different kinds of coffees (Biologico, Dolce, Deciso, Guatemala) were investigated with and without capsules and the goal was to classify the volatiloma of each one by Small Sensor System (S3). The response of the semiconductor metal oxide sensors (MOX) of S3 where recorded, for all 288 replicates and after normalization ∆R/R0 was extracted as a feature. PCA analysis was used to compare and differentiate the same kind of coffee sample with and without a capsule. It could be concluded that the coffee capsules affect the quality, changing on the flavor profile of espresso coffee when extracted different methods confirming the use of s3 device as a rapid and user-friendly tool in the food quality control chain
How Coffee Capsules Affect the Volatilome in Espresso Coffee
Coffee capsules have become one of the most used methods to have a coffee in the last few years. In this work, coffee was prepared using a professional espresso coffee machine. We investigated the volatilome of four different polypropylene coffee capsule typologies (Biologico, Dolce, Deciso, Guatemala) with and without capsules in order to reveal the possible differences in the VOCs spectra. The volatilome of each one was singularly studied through an analysis by gas chromatography and mass spectrometry (GC–MS), checking the abundance of different VOCs in coffee extracted with and without a capsule protection and compared to its related sample. Furthermore, ANOVA and Tukey tests were applied to statistically identify and individuate the possible differences. As a result, it was found that coffee capsules, offer advantages of protecting coffee from oxidation or rancidity and, consequently extended shelf life as well as did not cause a reduction of volatile compounds intensity. Therefore, it is possible to conclude that the aroma of polypropylene coffee capsule extraction is not damaged compared to a traditional espresso
k-NN and k-NN-ANN Combined Classifier to Assess MOX Gas Sensors Performances Affected by Drift Caused by Early Life Aging
The drift of metal oxide semiconductor (MOX) chemical sensors is one of the most important topics in this field. The work aims to test the performance of MOX gas sensors over the aging process. Firstly, sensors were tested with ethanol to understand their behavior and response changes. In parallel, beers with different alcoholic content were analyzed to assess what happened in a real application scenario. With ethanol analysis, it was possible to quantify drift of the baseline of the sensors and changes that could affect their responses over time (from day 1 to day 51). Conversely, the beer dataset has been exploited to evaluate how two different classifiers perform the classification task based on the alcohol content of the samples. A hybrid k-nearest neighbors artificial neural network (k-NN-ANN) approach and “standard” k-NN were used to evaluate to distinguish among the samples when the measures were affected by drift. To achieve this goal, data acquired from day one to day six were used as training to predict data collected up to day 51. Overall, performances of the two methods were similar, even if the best result in terms of accuracy is reached by k-NN-ANN (96.51%)
Array of MOX Nanowire Gas Sensors for Wastewater Management
Water is a common fundamental resource for life. The effects of climate change, pollution and waste make it an increasingly scarce resource. Therefore, it becomes very important to monitor water quality to identify situations of possible harm to humans. In this study, incoming wastewater of the depuration plant of A2A Ciclo Idrico in Brescia has been analyzed with an array of MOX nanowire gas sensors. In addition, GC-MS technique has been used to relate sensors responses with the emitted VOCs of the samples. The ability of the system to recognize potable water from wastewater and chemically contaminated wastewater has been found. PCA and ANN methods have been employed in order to see how samples classes cluster and to assess the capability of the device to classify them properly, respectively