613 research outputs found

    AnonFACES: Anonymizing Faces Adjusted to Constraints on Efficacy and Security

    Get PDF
    Image data analysis techniques such as facial recognition can threaten individuals’ privacy. Whereas privacy risks often can be reduced by adding noise to the data, this approach reduces the utility of the images. For this reason, image de-identification techniques typically replace directly identifying features (e.g., faces, car number plates) present in the data with synthesized features, while still preserving other non-identifying features. As of today, existing techniques mostly focus on improving the naturalness of the generated synthesized images, without quantifying their impact on privacy. In this paper, we propose the first methodology and system design to quantify, improve, and tune the privacy-utility trade-off, while simultaneously also improving the naturalness of the generated images. The system design is broken down into three components that address separate but complementing challenges. This includes a two-step cluster analysis component to extract low-dimensional feature vectors representing the images (embedding) and to cluster the images into fixed-sized clusters. While the importance of good clustering mostly has been neglected in previous work, we find that our novel approach of using low-dimensional feature vectors can improve the privacy-utility trade-off by better clustering similar images. The use of these embeddings has been found particularly useful when wanting to ensure high naturalness and utility of the synthetically generated images. By combining improved clustering and incorporating StyleGAN, a state-of-the-art Generative Neural Network, into our solution, we produce more realistic synthesized faces than prior works, while also better preserving properties such as age, gender, skin tone, or even emotional expressions. Finally, our iterative tuning method exploits non-linear relations between privacy and utility to identify good privacy-utility trade-offs. We note that an example benefit of these improvements is that our solution allows car manufacturers to train their autonomous vehicles while complying with privacy laws

    Design and validation of Segment - freely available software for cardiovascular image analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format.</p> <p>Results</p> <p>Segment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page <url>http://segment.heiberg.se</url>.</p> <p>Conclusions</p> <p>Segment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited.</p

    Complete chloroplast genome sequence of Holoparasite Cistanche Deserticola (Orobanchaceae) reveals gene loss and horizontal gene transfer from Its host Haloxylon Ammodendron (Chenopodiaceae)

    Get PDF
    The central function of chloroplasts is to carry out photosynthesis, and its gene content and structure are highly conserved across land plants. Parasitic plants, which have reduced photosynthetic ability, suffer gene losses from the chloroplast (cp) genome accompanied by the relaxation of selective constraints. Compared with the rapid rise in the number of cp genome sequences of photosynthetic organisms, there are limited data sets from parasitic plants. The authors report the complete sequence of the cp genome of Cistanche deserticola, a holoparasitic desert species belonging to the family Orobanchaceae

    Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT) in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem.</p> <p>Methods</p> <p>In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR) with delayed-enhancement technique to confirm or exclude myocardial infarction.</p> <p>Results</p> <p>There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR.</p> <p>Conclusion</p> <p>Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.</p

    Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Three-dimensional time-resolved (4D) phase-contrast (PC) CMR can visualize and quantify cardiovascular flow but is hampered by long acquisition times. Acceleration with SENSE or k-t BLAST are two possibilities but results on validation are lacking, especially at 3 T. The aim of this study was therefore to validate quantitative in vivo cardiac 4D-acquisitions accelerated with parallel imaging and k-t BLAST at 1.5 T and 3 T with 2D-flow as the reference and to investigate if field strengths and type of acceleration have major effects on intracardiac flow visualization.</p> <p>Methods</p> <p>The local ethical committee approved the study. 13 healthy volunteers were scanned at both 1.5 T and 3 T in random order with 2D-flow of the aorta and main pulmonary artery and two 4D-flow sequences of the heart accelerated with SENSE and k-t BLAST respectively. 2D-image planes were reconstructed at the aortic and pulmonary outflow. Flow curves were calculated and peak flows and stroke volumes (SV) compared to the results from 2D-flow acquisitions. Intra-cardiac flow was visualized using particle tracing and image quality based on the flow patterns of the particles was graded using a four-point scale.</p> <p>Results</p> <p>Good accuracy of SV quantification was found using 3 T 4D-SENSE (r<sup>2 </sup>= 0.86, -0.7 ± 7.6%) and although a larger bias was found on 1.5 T (r<sup>2 </sup>= 0.71, -3.6 ± 14.8%), the difference was not significant (p = 0.46). Accuracy of 4D k-t BLAST for SV was lower (p < 0.01) on 1.5 T (r<sup>2 </sup>= 0.65, -15.6 ± 13.7%) compared to 3 T (r<sup>2 </sup>= 0.64, -4.6 ± 10.0%). Peak flow was lower with 4D-SENSE at both 3 T and 1.5 T compared to 2D-flow (p < 0.01) and even lower with 4D k-t BLAST at both scanners (p < 0.01). Intracardiac flow visualization did not differ between 1.5 T and 3 T (p = 0.09) or between 4D-SENSE or 4D k-t BLAST (p = 0.85).</p> <p>Conclusions</p> <p>The present study showed that quantitative 4D flow accelerated with SENSE has good accuracy at 3 T and compares favourably to 1.5 T. 4D flow accelerated with k-t BLAST underestimate flow velocities and thereby yield too high bias for intra-cardiac quantitative in vivo use at the present time. For intra-cardiac 4D-flow visualization, however, 1.5 T and 3 T as well as SENSE or k-t BLAST can be used with similar quality.</p

    Regional changes in reactive hyperemic blood flow during exercise training: time-course adaptations

    Get PDF
    BACKGROUND: Few studies have examined the time-course of localized exercise training on regional blood flow in humans. The study examined the influence of handgrip exercise training on forearm reactive hyperemic blood flow and vascular resistance in apparently healthy men. METHODS: Forearm blood flow and vascular resistance were evaluated, in 17 individuals [Age: 22.6 ± 3.5], in both arms, at rest and following 5 minutes of arterial occlusion, using strain gauge plethysmography, prior to training (V1) and every week thereafter (V2-5) for 4 weeks. Handgrip exercise was performed in the non-dominant arm 5 d/wk for 20 minutes at 60% of maximum voluntary contraction, while the dominant arm served as control. RESULTS: Resting HR, BP, and forearm blood flow and vascular resistance were not altered with training. The trained arm handgrip strength and circumference increased by 14.5% (p = 0.014) and 1.56% (p = 0.03), respectively. ANOVA tests revealed an arms by visit interaction for the trained arm for reactive hyperemic blood flow (p = 0.02) and vascular resistance (p = 0.009). Post-hoc comparison demonstrated increased reactive hyperemic blood flow (p = 0.0013), and decreased post-occlusion vascular resistance (p = 0.05), following the 1(st )week of training, with no significant changes in subsequent visits. CONCLUSION: The results indicate unilateral improvements in forearm reactive hyperemic blood flow and vascular resistance following 1 week of handgrip exercise training and leveled off for the rest of the study

    Educational paper: Defects in number and function of neutrophilic granulocytes causing primary immunodeficiency

    Get PDF
    The neutrophilic granulocyte (neutrophil) is the most important cellular component of the innate immune system. A total absence of neutrophils or a significant decrease in their number leads to severe immunodeficiency. A mature neutrophil, released from the bone marrow, should be able to migrate from the blood towards the tissues, following a chemotactic gradient to a pathogen. In order to be neutralized, this pathogen has to be recognized, phagocytosed, and destroyed by lytic enzymes contained in the neutrophil's granules and reactive oxygen species formed by the enzyme complex NADPH oxidase. Rare genetic defects leading to the loss of each one of these biological properties of the neutrophil have been described and are associated with immunodeficiency. This review provides a summary of the normal development and biological functions of neutrophils and describes the diseases caused by defects in neutrophil number and function

    Fetus-derived DLK1 is required for maternal metabolic adaptations to pregnancy and is associated with fetal growth restriction.

    Get PDF
    Pregnancy is a state of high metabolic demand. Fasting diverts metabolism to fatty acid oxidation, and the fasted response occurs much more rapidly in pregnant women than in non-pregnant women. The product of the imprinted DLK1 gene (delta-like homolog 1) is an endocrine signaling molecule that reaches a high concentration in the maternal circulation during late pregnancy. By using mouse models with deleted Dlk1, we show that the fetus is the source of maternal circulating DLK1. In the absence of fetally derived DLK1, the maternal fasting response is impaired. Furthermore, we found that maternal circulating DLK1 levels predict embryonic mass in mice and can differentiate healthy small-for-gestational-age (SGA) infants from pathologically small infants in a human cohort. Therefore, measurement of DLK1 concentration in maternal blood may be a valuable method for diagnosing human disorders associated with impaired DLK1 expression and to predict poor intrauterine growth and complications of pregnancy.M.A.M.C. was supported by a PhD studentship from the Cambridge Centre for Trophoblast Research. Research was supported by grants from the MRC (MR/J001597/1 and MR/L002345/1), the Medical College of Saint Bartholomew's Hospital Trust, a Wellcome Trust Investigator Award, EpigeneSys (FP7 Health-257082), EpiHealth (FP7 Health-278414), a Herchel Smith Fellowship (N.T.) and NIH grant RO1 DK89989. The contents are the authors' sole responsibility and do not necessarily represent official NIH views. We thank G. Burton for invaluable support, and M. Constância and I. Sandovici (University of Cambridge) for the Meox2-cre mice. We are extremely grateful to all of the participants in the Pregnancy Outcome Prediction study. This work was supported by the NIHR Cambridge Comprehensive Biomedical Research Centre (Women's Health theme) and project grants from the MRC (G1100221) and Sands (Stillbirth and Neonatal Death Charity). The study was also supported by GE Healthcare (donation of two Voluson i ultrasound systems for this study) and by the NIHR Cambridge Clinical Research Facility, where all research visits took place.This is the author accepted manuscript. The final version is available from Nature Publishing Group via https://doi.org/10.1038/ng.369
    corecore