42 research outputs found

    Transapical aortic valve implantation in humans

    Get PDF

    Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN XT transcatheter heart valve system

    Get PDF
    BACKGROUND: Patients with congenital or acquired heart defects affecting the pulmonary valve and right ventricular outflow tract (RVOT) commonly require multiple surgical interventions, resulting in significant morbidity. A less invasive alternative is percutaneous pulmonary valve implantation (PPVI). Though studies have previously reported the safety and efficacy of the early generation transcatheter heart valves (THVs), data on more recent devices are severely lacking. METHODS AND RESULTS: We performed a multinational, multicentre, retrospective, observational registry analysis of patients who underwent PPVI using the Edwards SAPIEN XT THV. Of the 46 patients that were enrolled, the majority had tetralogy of Fallot as the underlying diagnosis (58.7%), and stentless xenograft as the most common RVOT anatomy (34.8%). Procedural success rate was high (93.5%), with a low frequency of periprocedural complications and adverse events (6.5% and 10.9%, respectively). At 30days post-procedure, NYHA class had improved significantly (90.6% were at NYHA I or II). The rate of moderate/severe pulmonary regurgitation had decreased from 76.1% at baseline to 5.0% at 30days, and the calculated peak systolic gradient had decreased from 45.2 (SD±21.3) mmHg to 16.4 (SD±8.0) mmHg, with these values remaining low up to 2years. CONCLUSIONS: The data suggest the efficacy and safety of the SAPIEN XT THV in PPVI in common anatomies in patients with conduits, as well as those with native pulmonary valves or transannular patches. Continued data collection is necessary to verify long-term findings

    Outcome of Patients After Transcatheter Aortic Valve Embolization

    Get PDF
    ObjectivesThis study aims to assess the mid- to long-term follow-up of patients after valve embolization at the time of transcatheter aortic valve implantation (TAVI).BackgroundTranscatheter heart valve (THV) embolization is a rare but serious complication during TAVI. Although various techniques have been developed to manage acute complications and reduce periprocedural morbidity/mortality, long-term clinical and hemodynamic consequences after these events are unknown.MethodsPatients who developed THV embolization after TAVI were prospectively assessed. Clinical and echocardiographic characteristics were recorded at baseline and after successful TAVI/surgical aortic valve replacement. The THV migration and strut fractures/degeneration were assessed by computed tomography.ResultsA total of 7 patients had THV embolization, all of which occurred immediately after valve deployment. The embolized THV was repositioned in the aortic arch proximal to the left subclavian artery (n = 2), immediately distal to the left subclavian artery (n = 2), and in the abdominal aorta (n = 3). A second THV was implanted successfully at the same sitting in 4 patients and at the time of a second procedure in 2 patients. Elective conventional aortic valve replacement was performed in 1 patient. Median follow-up was 1,085 days. One patient died during follow-up from an unrelated cause. The remaining 6 survivors were in New York Heart Association functional class I or II at final follow-up. Mid-term computed tomography follow-up (n = 4,591 to 1,548 days) showed that the leaflets of the embolized THV remain open in all phases of the cardiac cycle. There was also no strut fracture or migration of these valves.ConclusionsClinical outcomes remain good when THV embolization is managed effectively. There are no apparent hemodynamic consequences of a second valve placed in the series. These embolized valves remain in a stable position with no evidence of strut fractures at mid-term follow-up

    Percutaneous coronary intervention for cardiogenic shock in the SHOCK trial

    Get PDF
    AbstractObjectivesWe examined the clinical, angiographic, and procedural characteristics determining survival after percutaneous coronary intervention (PCI) for cardiogenic shock.BackgroundThe SHOCK (SHould we emergently revascularize Occluded coronaries for Cardiogenic shocK?) trial prospectively enrolled patients with shock complicating acute myocardial infarction (MI). Patients were randomized to a strategy of early revascularization or initial medical stabilization.MethodsPatients randomized to early revascularization underwent PCI or bypass surgery on the basis of predefined clinical criteria. Patients randomized to early revascularization who underwent PCI and had angiographic films available for analysis are the subject of this report (n = 82).ResultsThe median time from MI to PCI was 11 h. The majority of patients had occluded culprit arteries (Thrombolysis In Myocardial Infarction [TIMI] grade 0 or 1 flow in 62%) and multivessel disease (81%). One-year mortality in PCI patients was 50%. Mortality was 39% if PCI was successful but 85% if unsuccessful (p < 0.001). Mortality was 38% if TIMI flow grade 3 was achieved, 55% with TIMI grade 2 flow, and 100% with TIMI grade 0 or 1 flow (p < 0.001). Mortality was 67% if severe mitral regurgitation was documented. Independent correlates of mortality were as follows: increasing age (p < 0.001), lower systolic blood pressure (p = 0.009), increasing time from randomization to PCI (p = 0.019), lower post-PCI TIMI flow (0/1 vs. 2/3) (p < 0.001), and multivessel PCI (p = 0.040).ConclusionsRestoration of coronary blood flow is a major predictor of survival in cardiogenic shock. Benefit appears to extend beyond the generally accepted 12-h post-infarction window. Surgery should be considered in shock patients with severe mitral insufficiency or multivessel disease not amenable to relatively complete percutaneous revascularization

    Customized covered stent graft for percutaneous closure of Fontan baffle leak

    Full text link
    We report the innovation of both a partly-covered and completely-covered, variable-diameter, balloon-expandable stent that was custom-designed by NuMed, Inc for percutaneous closure of a baffle leak after total caval pulmonary connection (TCPC). A 50-year-old patient, born with tricuspid atresia, who had undergone TCPC, developed severe persistent cyanosis due to a right-to-left shunt through a TCPC baffle leak. Re-operation was deemed too high risk. Therefore, considering his complex anatomy, a custom-made, partly-covered, tapered, balloon-expandable stent was designed and successfully deployed. Months later, the shunt recurred at the junction of the covered to uncovered stent cells; subsequently, a second fully-covered, custom-made, tapered stent was implanted with an excellent outcome. The use of covered or partly-covered customized variable-diameter stents for closure of baffle leak after TCPC is feasible and resulted in marked clinical improvement. Customized balloon-expandable stents may be superior to traditional cylindrical stents because of better anchoring and apposition
    corecore