391 research outputs found
Laue Lens Development for Hard X-rays (>60 keV)
Results of reflectivity measurements of mosaic crystal samples of Cu (111)
are reported. These tests were performed in the context of a feasibility study
of a hard X-ray focusing telescope for space astronomy with energy passband
from 60 to 600 keV. The technique envisaged is that of using mosaic crystals in
transmission configuration that diffract X-rays for Bragg diffraction (Laue
lens). The Laue lens assumed has a spherical shape with focal length . It is
made of flat mosaic crystal tiles suitably positioned in the lens. The samples
were grown and worked for this project at the Institute Laue-Langevin (ILL) in
Grenoble (France), while the reflectivity tests were performed at the X-ray
facility of the Physics Department of the University of Ferrara.Comment: 6 pages, 12 figures, accepted for publication in IEEE Transactions on
Nuclear Scienc
The OLYMPUS Internal Hydrogen Target
An internal hydrogen target system was developed for the OLYMPUS experiment
at DESY, in Hamburg, Germany. The target consisted of a long, thin-walled,
tubular cell within an aluminum scattering chamber. Hydrogen entered at the
center of the cell and exited through the ends, where it was removed from the
beamline by a multistage pumping system. A cryogenic coldhead cooled the target
cell to counteract heating from the beam and increase the density of hydrogen
in the target. A fixed collimator protected the cell from synchrotron radiation
and the beam halo. A series of wakefield suppressors reduced heating from beam
wakefields. The target system was installed within the DORIS storage ring and
was successfully operated during the course of the OLYMPUS experiment in 2012.
Information on the design, fabrication, and performance of the target system is
reported.Comment: 9 pages, 13 figure
Development status of the LAUE project
We present the status of LAUE, a project supported by the Italian Space
Agency (ASI), and devoted to develop Laue lenses with long focal length (up to
100 meters), for hard X--/soft gamma--ray astronomy (80-600 keV). Thanks to
their focusing capability, the design goal is to improve the sensitivity of the
current instrumention in the above energy band by 2 orders of magnitude, down
to a few times photons/(cm s keV).Comment: 9 pages, 9 figures, presented at the Space Telescopes and
Instrumentation Symposium in Amsterdam, 2012: Ultraviolet to Gamma Ray
Conference. Published in the Proceedings of the SPIE, Volume 8443, id.
84430B-84430B-9 (2012
Development status of a Laue lens project for gamma-ray astronomy
We report the status of the HAXTEL project, devoted to perform a design study
and the development of a Laue lens prototype. After a summary of the major
results of the design study, the approach adopted to develop a Demonstration
Model of a Laue lens is discussed, the set up described, and some results
presented.Comment: 11 pages, 11 figures, 2007 SPIE Conference on Optics for EUV, X-Ray,
and Gamma-Ray Astronomy II
Exploring the Hard X-/soft gamma-ray Continuum Spectra with Laue Lenses
The history of X-ray astronomy has shown that any advancement in our
knowledge of the X-ray sky is strictly related to an increase in instrument
sensitivity. At energies above 60 keV, there are interesting prospects for
greatly improving the limiting sensitivity of the current generation of direct
viewing telescopes (with or without coded masks), offered by the use of Laue
lenses. We will discuss below the development status of a Hard X-Ray focusing
Telescope (HAXTEL) based on Laue lenses with a broad bandpass (from 60 to 600
keV) for the study of the X-ray continuum of celestial sources. We show two
examplesof multi-lens configurations with expected sensitivity orders of
magnitude better ( photons cm s keV
at 200 keV) than that achieved so far. With this unprecedented sensitivity,
very exciting astrophysical prospects are opened.Comment: 4 pages, 10 figures, to be published in the Proc. of the 39th ESLAB
Symosium, 19-21 April 200
A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector
that collects data provided by the collision in the Beijing Electron Positron
Collider II (BEPCII), hosted at the Institute of High Energy Physics of
Beijing. Since the beginning of its operation, BESIII has collected the world
largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the
luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC
decreases its efficiency in the first layers up to 35% with respect to the
value in 2014. Since BESIII has to take data up to 2022 with the chance to
continue up to 2027, the Italian collaboration proposed to replace the inner
part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM).
The CGEM-IT project will deploy several new features and innovation with
respect the other current GEM based detector: the {\mu}TPC and analog readout,
with time and charge measurements will allow to reach the 130 {\mu}m spatial
resolution in 1 T magnetic field requested by the BESIII collaboration. In this
proceeding, an update of the status of the project will be presented, with a
particular focus on the results with planar and cylindrical prototypes with
test beams data. These results are beyond the state of the art for GEM
technology in magnetic field
Scientific prospects in soft gamma-ray astronomy enabled by the LAUE project
This paper summarizes the development of a successful project, LAUE,
supported by the Italian Space Agency (ASI) and devoted to the development of
long focal length (up to 100 m) Laue lenses for hard X--/soft gamma--ray
astronomy (80-600 keV). The apparatus is ready and the assembling of a
prototype lens petal is ongoing. The great achievement of this project is the
use of bent crystals. From measurements obtained on single crystals and from
simulations, we have estimated the expected Point Spread Function and thus the
sensitivity of a lens made of petals. The expected sensitivity is a few
photons cm s keV. We discuss a number of
open astrophysical questions that can settled with such an instrument aboard a
free-flying satellite.Comment: 17 pages, 18 figures, published in Proceedings of the SPIE, Volume
8861, id. 886106 17 pp. (2013
Mirror system of the RICH detector of the NA62 experiment
A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion selection by a factor 100 in the momentum range between 15 and 35 GeV/c. The detector consists of a 17 m long tank (vessel), filled with neon gas at atmospheric pressure. Cherenkov light is reflected by a mosaic of 20 spherical mirrors with 17 m focal length, placed at the downstream end, and collected by 1952 photomultipliers (PMTs) placed at the upstream end. In this paper the characterization of the mirrors before installation and the mirror support system are described. The mirror installation procedure and the laser alignment are also illustrated
Hard Two-Photon Contribution to Elastic Lepton-Proton Scattering: Determined by the OLYMPUS Experiment
The OLYMPUS collaboration reports on a precision measurement of the
positron-proton to electron-proton elastic cross section ratio, ,
a direct measure of the contribution of hard two-photon exchange to the elastic
cross section. In the OLYMPUS measurement, 2.01~GeV electron and positron beams
were directed through a hydrogen gas target internal to the DORIS storage ring
at DESY. A toroidal magnetic spectrometer instrumented with drift chambers and
time-of-flight scintillators detected elastically scattered leptons in
coincidence with recoiling protons over a scattering angle range of to . The relative luminosity between the two beam species
was monitored using tracking telescopes of interleaved GEM and MWPC detectors
at , as well as symmetric M{\o}ller/Bhabha calorimeters at
. A total integrated luminosity of 4.5~fb was collected. In
the extraction of , radiative effects were taken into account
using a Monte Carlo generator to simulate the convolutions of internal
bremsstrahlung with experiment-specific conditions such as detector acceptance
and reconstruction efficiency. The resulting values of , presented
here for a wide range of virtual photon polarization ,
are smaller than some hadronic two-photon exchange calculations predict, but
are in reasonable agreement with a subtracted dispersion model and a
phenomenological fit to the form factor data.Comment: 5 pages, 3 figures, 2 table
- âŠ