4,074 research outputs found

    Straining Their Brains: Why the Case Against Enhancement is Not Persuasive.

    Get PDF
    Your kid’s schoolwork not up to par? Looking for Mr. or Ms. Right? Any other problems caused by a mind’s eye seemingly not quite on the ball? Answers might lie in a brain-enhancing pill. Some argue this is merely better living through chemistry and in line with humanity’s self-improving actions throughout history, but others suggest that quick-fix medications could well distort the very things that make us human. Here a leading bioethicist squares off with a member of the President’s Council on Bioethics on the controversy about pursuing better brains with a little help from biotechnology

    Implementation and validation of a CubeSat laser transmitter

    Get PDF
    The paper presents implementation and validation results for a CubeSat-scale laser transmitter. The master oscillator power amplifier (MOPA) design produces a 1550 nm, 200mW average power optical signal through the use of a directly modulated laser diode and a commercial fiber amplifier. The prototype design produces high-fidelity M-ary pulse position modulated (PPM) waveforms (M=8 to 128), targeting data rates > 10 Mbit/s while meeting a constraining 8W power allocation. We also present the implementation of an avalanche photodiode (APD) receiver with measured transmitter-to-receiver performance within 3 dB of theory. Via loopback, the compact receiver design can provide built-in self-test and calibration capabilities, and supports incremental on-orbit testing of the design

    Feasiblity study for a 34 GHz (Ka band) gyroamplifier

    Get PDF
    The feasibility of using a gyroklystron power tube as the final amplifier in a 400 kW CW 34 GHz transmitter on the Goldstone Antenna is investigated. A conceptual design of the gyroklystron and the transmission line connecting it with the antenna feed horn is presented. The performance characteristics of the tube and transmission line are compared to the transmitter requirements for a deep space radar system. Areas of technical risk for a follow-on hardware development program for the gyroklystron amplifier and overmoded transmission line components are discussed

    Bioethics and the Brain

    Get PDF
    Microelectronics and medical imaging are bringing us closer to a world where mind reading is possible and blindness banished - but we may not want to live there. New ways of imaging the human brain and new developments in microelectronics are providing unprecedented capabilities for monitoring the brain in real time and even for controlling brain function. The technologies are novel, but some of the questions that they will raise are not. Electrical activity in the brain can reveal the contents of a person\u27s memory. New imaging techniques might allow physician to detect devastating diseases long before those diseases become clinically apparent. And researchers may one day find brain activity that correlates with behavior patterns such as tendencies toward alcoholism, aggression, pedophilia, or racism. But how reliable will the information be, how should it be used, and what will it do to our notion of privacy? Meanwhile, microelectronics is making access to the brain a two-way street. The same electrical stimulation technologies that allow some deaf people to hear could be fashioned to control behavior as well. What are the appropriate limits to the use of this technology? Ethicists are only now beginning to take note of these developments in neuroscience

    Current Concepts of Cerebrovascular Disease - Stroke: Stroke and Drug Abuse

    Get PDF
    This Review Summarizes Available Information Concerning Cerebral Vascular Complications of the Most Commonly Abused Substances and Discusses Possible Mechanisms of Vascular Injury and Cerebral Damage. Although Alcohol is Frequently Abused and May Have Important Cerebrovascular Effects, its Consideration is Beyond the Scope of This Review

    Cerebral Embolism in the Michael Reese Stroke Registry

    Get PDF
    Infarction Secondary to Cerebral Embolism Was Diagnosed in 127 (23.5%) of 540 Patients in the Michael Reese Stroke Registry. Coronary Artery Disease, Atrial Fibrillation, Valvular Heart Disease, Mitral Annulus Calcification, and Cardiomyopathy Were the Commonest Etiologies. Echocardiography Documented a Potential Embolic Source in 7 Patients Without Previously Known Heart Disease and Clarified the Cardiac Pathology in Many of the Patients with Known Heart Disease. the Left Anterior Circulation Was Affected in 48%, Right Anterior in 37%, and Posterior Circulation in 15% of patients. CT Was Abnormal in 71% of the Patients and Was Approximately Equally Helpful in All Locations. Nineteen Percent of Emboli Presented with a Deficit that Was Other Than Maximal at Onset. Concurrent Systemic Embolism Was Unusual (2.3%). Prognosis Was Somewhat Worse Than in Thrombotic Stroke. Grouping of Patients According to Embolic Source (Intra-Arterial, Cardiac, and Uncertain Source) Showed No Differences in Activity at Onset, Early Course, or in Subsequent Course of the Illness
    • …
    corecore