70 research outputs found

    Recurrent Hepatitis C in Liver Allografts: Prospective Assessment of Diagnostic Accuracy, Identification of Pitfalls, and Observations about Pathogenesis

    Get PDF
    Rationale and Design: The accuracy of a prospective histopathologic diagnosis of rejection and recurrent hepatitis C (HCV) was determined in 48 HCV RNA-positive liver allograft recipients enrolled in an "immunosuppression minimization protocol" between July 29, 2001 and January 24, 2003. Prospective entry of all pertinent treatment, laboratory, and histopathology results into an electronic data-base enabled a retrospective analysis of the accuracy of histopathologic diagnoses and the pathophysiologic relationship between recurrent HCV and rejection. Results: Time to first onset of acute rejection (AR) (mean, 107 days; median, 83 days; range, 7-329 days) overlapped with the time to first onset of recurrent HCV (mean, 115 days; median, 123 days; range, 22-315 days), making distinction between the two difficult. AR and chronic rejection (CR) with and without co-existent HCV showed overlapping but significantly different liver injury test profiles. One major and two minor errors occurred (positive predictive values for AR = 91%; recurrent HCV = 100%) ; all involved an overdiagnosis of AR in the context of recurrent HCV. Retrospective analysis of the mistakes showed that major errors can be avoided altogether and the impact of unavoidable minor errors can be minimized by strict adherence to specific histopathologic criteria, close clinicopathologic correlation including examination of HCV RNA levels, and a conservative approach to the use of additional immunosuppression. In addition, histopathologic diagnoses of moderate and severe AR and CR were associated with relatively low HCV RNA levels, whereas relatively high HCV RNA levels were associated with a histopathologic diagnosis of hepatitis alone, particularly the cholestatic variant of HCV. Conclusions: Liver allograft biopsy interpretation can rapidly and accurately distinguish between recurrent HCV and AR/CR. In addition, the histopathologic observations suggest that the immune mechanism responsible for HCV clearance overlap with those leading to significant rejection

    DCs Pulsed with Novel HLA-A2-Restricted CTL Epitopes against Hepatitis C Virus Induced a Broadly Reactive Anti-HCV-Specific T Lymphocyte Response

    Get PDF
    OBJECTIVE: To determine the capacity of dendritic cells (DCs) loaded with single or multiple-peptide mixtures of novel hepatitis C virus (HCV) epitopes to stimulate HCV-specific cytotoxic T lymphocyte (CTL) effector functions. METHODS: A bioinformatics approach was used to predict HLA-A2-restricted HCV-specific CTL epitopes, and the predicted peptides identified from this screen were synthesized. Subsequent IFN-Îł ELISPOT analysis detected the stimulating function of these peptides in peripheral blood mononuclear cells (PBMCs) from both chronic and self-limited HCV infected subjects (subjects exhibiting spontaneous HCV clearance). Mature DCs, derived in vitro from CD14(+) monocytes harvested from the study subjects by incubation with appropriate cytokine cocktails, were loaded with novel peptide or epitope peptide mixtures and co-cultured with autologous T lymphocytes. Granzyme B (GrB) and IFN-Îł ELISPOT analysis was used to test for epitope-specific CTL responses. T-cell-derived cytokines contained in the co-cultured supernatant were detected by flow cytometry. RESULTS: We identified 7 novel HLA-A2-restricted HCV-specific CTL epitopes that increased the frequency of IFN-Îł-producing T cells compared to other epitopes, as assayed by measuring spot forming cells (SFCs). Two epitopes had the strongest stimulating capability in the self-limited subjects, one found in the E2 and one in the NS2 region of HCV; five epitopes had a strong stimulating capacity in both chronic and self-limited HCV infection, but were stronger in the self-limited subjects. They were distributed in E2, NS2, NS3, NS4, and NS5 regions of HCV, respectively. We also found that mDCs loaded with novel peptide mixtures could significantly increase GrB and IFN-Îł SFCs as compared to single peptides, especially in chronic HCV infection subjects. Additionally, we found that DCs pulsed with multiple epitope peptide mixtures induced a Th1-biased immune response. CONCLUSIONS: Seven novel and strongly stimulating HLA-A2-restricted HCV-specific CTL epitopes were identified. Furthermore, DCs loaded with multiple-epitope peptide mixtures induced epitope-specific CTLs responses

    Consequences of Cold-Ischemia Time on Primary Nonfunction and Patient and Graft Survival in Liver Transplantation: A Meta-Analysis

    Get PDF
    Introduction: The ability to preserve organs prior to transplant is essential to the organ allocation process. Objective: The purpose of this study is to describe the functional relationship between cold-ischemia time (CIT) and primary nonfunction (PNF), patient and graft survival in liver transplant. Methods: To identify relevant articles Medline, EMBASE and the Cochrane database, including the non-English literature identified in these databases, was searched from 1966 to April 2008. Two independent reviewers screened and extracted the data. CIT was analyzed both as a continuous variable and stratified by clinically relevant intervals. Nondichotomous variables were weighted by sample size. Percent variables were weighted by the inverse of the binomial variance. Results: Twenty-six studies met criteria. Functionally, PNF%=-6.678281+0.9134701*CIT Mean+0.1250879*(CIT Mean-9.89535) 2 - 0.0067663*(CIT Mean-9.89535) 3, r2=.625, p<.0001. Mean patient survival: 93 % (1 month), 88 % (3 months), 83 % (6 months) and 83 % (12 months). Mean graft survival: 85.9 % (1 month), 80.5 % (3 months), 78.1 % (6 months) and 76.8 % (12 months). Maximum patient and graft survival occurred with CITs between 7.5-12.5 hrs at each survival interval. PNF was also significantly correlated with ICU time, % first time grafts and % immunologic mismatches. Conclusion: The results of this work imply that CIT may be the most important pre-transplant information needed in the decision to accept an organ. © 2008 Stahl et al

    Three-part humeral head fractures treated with a definite construct of blocked threaded wires: finite element and parametric optimization analysis

    No full text
    Background: Mini open reduction and percutaneous fixation of three-part humeral head fracture with blocked threaded wires has demonstrated functional results similar to locking plates or intramedullary nails but with significantly lower major complication rate. In the context of three-part humeral head fractures, we performed a parametric optimization through a finite element analysis of a recently published construct to verify if the encouraging clinical results can be supported by a more rigorous investigation from a mechanical viewpoint. Materials and Methods: The 2-dimensional geometry of a three-part proximal humerus fracture synthetized with a system of blocked threaded wires was created. Tension/bending/shear and compression load tests were simulated. A parametric optimization analysis was performed considering four design parameters (height of wire couples; wire material; interdistance between two wires). Eighteen simulations were carried out. Additional analyses were performed also considering a varying diameter of the external rod. Results: Four points where the largest gap occurs and three points associated with the highest stress concentration were considered. As per the tension/bending/shear loading, a slight gap increase was observed in two different points (8.494 ÎĽm; 7.540 ÎĽm), while a slight decrease was detected along the greater tuberosity fracture line (1.445 ÎĽm). The maximum von Mises stress up to 64.4 MPa was achieved in the humeral head. As per the compression loading, the gap increased along the greater tuberosity fracture line (1.445 ÎĽm; 7.545ÎĽm); the maximum von Mises stress attains the value of 64.42 MPa. The smallest gap distance (15.37ÎĽm) and the lowest von Mises stress (51.51 MPa) were obtained in two different alternative constructs. The diameter of the external rod had no significant effect. Conclusions: The studied construct is biomechanically valid; it only allows micromovements (one-thousandth of the characteristic humerus size) that are not able to cause humeral head rotation and translation. Furthermore, the construct generates acceptable pressure stresses on sensible areas of the fractured humeral head. Compared to the original construct, we propose to space the pair of horizontal wires for the great tuberosity by at least 1 cm
    • …
    corecore