2,546 research outputs found

    Pseudospin-1 Physics of Photonic Crystals.

    Get PDF
    We review some recent progress in the exploration of pseudospin-1 physics using dielectric photonic crystals (PCs). We show some physical implications of the PCs exhibiting an accidental degeneracy induced conical dispersion at the Γ point, such as the realization of zero refractive index medium and the zero Berry phase of a loop around the nodal point. The photonic states of such PCs near the Dirac-like point can be described by an effective spin-orbit Hamiltonian of pseudospin-1. The wave propagation in the positive, negative, and zero index media can be unified within a framework of pseudospin-1 description. A scale change in PCs results in a rigid band shift of the Dirac-like cone, allowing for the manipulation of waves in pseudospin-1 systems in much the same way as applying a gate voltage in pseudospin-1/2 graphene. The transport of waves in pseudospin-1 systems exhibits many interesting phenomena, including super Klein tunneling, robust supercollimation, and unconventional Anderson localization. The transport properties of pseudospin-1 systems are distinct from their counterparts in pseudospin-1/2 systems, which will also be presented for comparison

    Is vocal cord asymmetry seen on transcutaneous laryngeal ultrasonography a significant predictor of voice quality changes after thyroidectomy?

    Get PDF
    Background: Vocal cord asymmetry (VCA) on laryngoscopic examination (LE) may suggest voice impairment after thyroidectomy, but LE may cause patient discomfort. We aimed to correlate the presence of postoperative VCA assessed by noninvasive transcutaneous laryngeal ultrasonography (TLUSG) with voice quality changes after thyroidectomy. Methods: A total of 169 patients scheduled for thyroidectomy completed two validated voice symptoms questionnaires - the GRBAS (grade, roughness, breathiness, asthenia, strain) scale and the voice impairment score (VIS) - and underwent TLUSG and LE at 1 day before and 7-10 days after thyroidectomy. Postoperative VCA was apparent in 51 patients on TLUSG (group I), whereas there was no VCA in the other 118 patients (group II, controls). The GRBAS scale and VIS results were compared between the groups. Results: Before operation, the two groups had comparable preoperative GRBAS and VIS status. After operation, the "grade" and "roughness" components on the GRBAS scale were significantly worse in group I than in group II: 0.24 versus 0.07 (p = 0.016) and 0.33 versus 0.14 (p = 0.022), respectively. "Grade" and "roughness" in the GRBAS scale significantly worsened after the operation in group I: from 0.04 to 0.24 (p = 0.008) and from 0.02 to 0.33 (p = 0.001), respectively. They did not change in group II. Also, the overall VIS was significantly worse after thyroidectomy in group I: 4.97 versus 12.97 (p < 0.001). Conclusions: VCA seen on TLUSG significantly correlated with "grade" and "roughness" components on the GRBAS scale and the overall VIS. Thus, VCA might be used as a surrogate of postoperative voice changes. © 2013 Société Internationale de Chirurgie.postprin

    Development of metal-containing polymers for optoelectronic applications

    Get PDF
    Most of the work in organic electroluminescent polymers has been focused on organic conjugated polymers. However, polymers attached with transition metal complex have received relatively less attention. We have synthesized and studied the light emitting properties of some metal containing polymers based on the polypyridine complexes of rhenium and ruthenium. These complexes exhibit long-lived excited states caused by the metal to ligand charge transfer transitions. By varying the structure of the ligand and/or the transition metal, we are able to fine-tune the electronic properties of the resulting metal complexes.We have synthesized a series of poly(phenylenevinylene) (PPV) derivatives which are functionalized with ruthenium polypyridine complexes at the polymer mainchain or side chain. These complexes are able to act as photosensitizers which enhance the photoconductivity of these polymers at longer wavelength. Both the conjugatedbackbone and the metal complex can emit light upon excitation. As a result, it is possible to tune the color by loading different amount of ruthenium complex to the polymer. Luminescence studies showed that the ruthenium complex could quench the emission of the conjugated backbone in some polymers, which suggests an energy transfer processbetween the backbone and the metal complexes. It was also found that the presence of metal complexes could enhance the charge carrier mobilities of the polymers, as the metal and/or ligands can act as extra charge carriers in the charge transport process.published_or_final_versio

    Dye-sensitized solar cells using ZnO tetrapods

    Get PDF
    One dimensional (1D) ZnO nanostructures are of interest for applications in dye-sensitized solar cells (DSSCs) since they exhibit significantly improved electron transport compared to that in porous films. However, 1D nanostructures also have a significantly lower surface area than the porous films. Thus, the achieved solar cell efficiencies are typically much lower in spite of the improved charge transport. In this work, we investigated DSSCs based on ZnO tetrapods to achieve an increased surface area compared to that of 1D nanostructures. The cell performance as a function of the tetrapod film thickness and the dye used was studied. To further increase the surface area, mixed morphologies (tetrapods with nanoparticles) were also investigated. Under optimal conditions, an AM 1.5 power conversion efficiency of ∼1.2% was achieved. © 2008 American Institute of Physics.published_or_final_versio

    One-by-one trap activation in silicon nanowire transistors

    Full text link
    Flicker or 1/f noise in metal-oxide-semiconductor field-effect transistors (MOSFETs) has been identified as the main source of noise at low frequency. It often originates from an ensemble of a huge number of charges trapping and detrapping. However, a deviation from the well-known model of 1/f noise is observed for nanoscale MOSFETs and a new model is required. Here, we report the observation of one-by-one trap activation controlled by the gate voltage in a nanowire MOSFET and we propose a new low-frequency-noise theory for nanoscale FETs. We demonstrate that the Coulomb repulsion between electronically charged trap sites avoids the activation of several traps simultaneously. This effect induces a noise reduction by more than one order of magnitude. It decreases when increasing the electron density in the channel due to the electrical screening of traps. These findings are technologically useful for any FETs with a short and narrow channel.Comment: One file with paper and supplementary informatio

    Cerebral involvement in neuromyelitis optica spectrum disorders among Hong Kong Chinese

    Get PDF
    published_or_final_versionThe 16th Medical Resarch Conference (MRC), The University of Hong Kong, Hong Kong, China, 22 January 2011. In Hong Kong Medical Journal, 2011, v. 17, suppl. 1, p. 55, abstract no. 8

    Predictive value of high-sensitivity troponin-I for future adverse cardiovascular outcome in stable patients with type 2 diabetes mellitus

    Get PDF
    INTRODUCTION: High-sensitivity cardiac troponin I(hs-TnI) and T levels(hs-TnT) are sensitive biomarkers of cardiomyocyte turnover or necrosis. Prior studies of the predictive role of hs-TnT in type 2 diabetes mellitus(T2DM) patients have yielded conflicting results. This study aimed to determine whether hs-TnI, which is detectable in a higher proportion of normal subjects than hsTnT, is associated with a major adverse cardiovascular event(MACE) in T2DM patients. METHODS AND RESULTS: We compared hs-TnI level in stored serum samples from 276 consecutive patients (mean age 65 +/- 10 years; 57% male) with T2DM with that of 115 age-and sex-matched controls. All T2DM patients were prospectively followed up for at least 4 years for incidence of MACE including heart failure(HF), myocardial infarction(MI) and cardiovascular mortality. At baseline, 274(99%) patients with T2DM had detectable hs-TnI, and 57(21%) had elevated hs-TnI (male: 8.5 ng/L, female: 7.6 ng/L, above the 99th percentile in healthy controls). A total of 43 MACE occurred: HF(n = 18), MI(n = 11) and cardiovascular mortality(n = 14). Kaplan-Meier analysis showed that an elevated hs-TnI was associated with MACE, HF, MI and cardiovascular mortality. Although multivariate analysis revealed that an elevated hs-TnI independently predicted MACE, it had limited sensitivity(62.7%) and positive predictive value(38.5%). Contrary to this, a normal hs-TnI level had an excellent negative predictive value(92.2%) for future MACE in patients with T2DM. CONCLUSION: The present study demonstrates that elevated hs-TnI in patients with T2DM is associated with increased MACE, HF, MI and cardiovascular mortality. Importantly, a normal hs-TnI level has an excellent negative predictive value for future adverse cardiovascular events during long-term follow-up.published_or_final_versio

    Surface reconstructions and stability of X-shaped carbon nanotube junction

    Get PDF
    Author name used in this publication: S. Q. Shi2005-2006 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe

    Casimir-induced instabilities at metallic surfaces and interfaces

    Get PDF
    Surface distortion splits surface plasmons asymmetrically in energy with a net lowering of zero-point energy. We contrast this with the symmetrical distortion of electronic energy levels. We use conformal mapping to demonstrate this splitting and find that surface corrugation always leads to a decrease in the zero-point energy of a metallic surface, but the decrease is not strong enough to drive a surface reconstruction on its own. A second metallic surface in proximity to the first gives a more significant lowering of energy, sufficient to drive the instability of a mercury thin film. This mechanism provides a fundamental length scale limit to planar nanostructures

    Early detection of neurodegeneration in brain ischemia by manganese-enhanced MRI

    Get PDF
    This study aims to employ in vivo manganese-enhanced MRI (MEMRI) to detect neurodegenerative changes in two models of brain ischemia, photothrombotic cortical injury (PCI) and transient middle cerebral artery occlusion (MCAO) in rodents. After systemic Mn 2+ injection to both ischemic models, a close pattern of Tl-weighted hyperintensity was observed throughout different brain regions in comparison to the distribution of GFAP, MnSOD and GS immunoreactivities, whereby conventional MRI could hardly detect such. In addition, the infarct volumes in the posterior parts of the brain had significantly reduced after Mn 2+ injection to the MCAO model. It is suggested that exogenous Mn 2+ injection may provide enhanced MEMRI detection of oxidative stress and gliosis early after brain ischemia. Manganese may also mediate infarctions at remote brain regions in transient focal cerebral ischemia before delayed secondary damage takes place. © 2008 IEEE.published_or_final_versionThe 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS) 2008, Vancouver, BC., 20-25 August 2008. in Proceedings of the 30th EMBS, 2008, p. 3884-388
    corecore