1,220 research outputs found

    A survey of the accuracy and use of three milk meters

    Get PDF
    Milk yields of 59, 15 and 31 cows were measured with the Milky Weigh, Bodmin and Johnson milk meters respectively, and comparisons were made with scale weights. Meters were accurate in one-third of readings. Most readings with the Milk Weigh meter were higher than weights (positive). Both high and low readings were noted on the Bodmin While most readings were lower than weights (negative) in the case of the Johnson. Of all readings, 83% (Milky Weigh), 74% (Bodmin) and 75% (Johnson) did not deviate more than +- 5 % from weights. Correlation coefficients of 0·9 were derived in the case of each meter. Regression coefficients were calculated and equations for regression lines prepared

    Nodes of the Gap Function and Anomalies in Thermodynamic Properties of Superfluid 3^3He

    Full text link
    Departures of thermodynamic properties of three-dimensional superfluid 3^3He from the predictions of BCS theory are analyzed. Attention is focused on deviations of the ratios Δ(T=0)/Tc\Delta(T=0)/T_c and [Cs(Tc)Cn(Tc)]/Cn(Tc)[C_s(T_c)-C_n(T_c)]/C_n(T_c) from their BCS values, where Δ(T=0)\Delta(T=0) is the pairing gap at zero temperature, TcT_c is the critical temperature, and CsC_s and CnC_n are the superfluid and normal specific heats. We attribute these deviations to the momentum dependence of the gap function Δ(p)\Delta(p), which becomes well pronounced when this function has a pair of nodes lying on either side of the Fermi surface. We demonstrate that such a situation arises if the P-wave pairing interaction V(p1,p2)V(p_1,p_2), evaluated at the Fermi surface, has a sign opposite to that anticipated in BCS theory. Taking account of the momentum structure of the gap function, we derive a closed relation between the two ratios that contains no adjustable parameters and agrees with the experimental data. Some important features of the effective pairing interaction are inferred from the analysis.Comment: 17 pages, 4 figure

    Generalized measurements by linear elements

    Get PDF
    I give a first characterization of the class of generalized measurements that can be exactly realized on a pair of qudits encoded in indistinguishable particles, by using only linear elements and particle detectors. Two immediate results follow from this characterization. (i) The Schmidt number of each POVM element cannot exceed the number of initial particles. This rules out any possibility of performing perfect Bell-measurements for qudits. (ii) The maximum probability of performing a generalized incomplete Bell-measurement is 1/2.Comment: 4 pages. Submitted to Phys. Rev.

    Geometric entangling gates for coupled cavity system in decoherence-free subspaces

    Full text link
    We propose a scheme to implement geometric entangling gates for two logical qubits in a coupled cavity system in decoherence-free subspaces. Each logical qubit is encoded with two atoms trapped in a single cavity and the geometric entangling gates are achieved by cavity coupling and controlling the external classical laser fields. Based on the coupled cavity system, the scheme allows the scalability for quantum computing and relaxes the requirement for individually addressing atoms.Comment: 6 pages, 1 figur

    Teleportation of a quantum state of a spatial mode with a single massive particle

    Full text link
    Mode entanglement exists naturally between regions of space in ultra-cold atomic gases. It has, however, been debated whether this type of entanglement is useful for quantum protocols. This is due to a particle number superselection rule that restricts the operations that can be performed on the modes. In this paper, we show how to exploit the mode entanglement of just a single particle for the teleportation of an unknown quantum state of a spatial mode. We detail how to overcome the superselection rule to create any initial quantum state and how to perform Bell state analysis on two of the modes. We show that two of the four Bell states can always be reliably distinguished, while the other two have to be grouped together due to an unsatisfied phase matching condition. The teleportation of an unknown state of a quantum mode thus only succeeds half of the time.Comment: 12 pages, 1 figure, this paper was presented at TQC 2010 and extends the work of Phys. Rev. Lett. 103, 200502 (2009

    IAEA methodology for on-site end-to-end IMRT/VMAT audits : an international pilot study

    Get PDF
    The IAEA has developed and tested an on-site, end-to-end IMRT/VMAT dosimetry audit methodology for head and neck cases using an anthropomorphic phantom. The audit methodology is described, and the results of the international pilot testing are presented. The audit utilizes a specially designed, commercially available anthropomorphic phantom capable of accommodating a small volume ion chamber (IC) in four locations (three in planning target volumes (PTVs) and one in an organ at risk (OAR)) and a Gafchromic film in a coronal plane for the absorbed dose to water and two-dimensional dose distribution measurements, respectively. The audit consists of a pre-visit and on-site phases. The pre-visit phase is carried out remotely and includes a treatment planning task and a set of computational exercises. The on-site phase aims at comparing the treatment planning system (TPS) calculations with measurements in the anthropomorphic phantom following an end-to-end approach. Two main aspects were tested in the pilot study: feasibility of the planning constraints and the accuracy of IC and film results in comparison with TPS calculations. Treatment plan quality was scored from 0 to 100. Results: Forty-two treatment plans were submitted by 14 institutions from 10 countries, with 79% of them having a plan quality score over 90. Seventeen sets of IC measurement results were collected, and the average measured to calculated dose ratio was 0.988 ± 0.016 for PTVs and 1.020 ± 0.029 for OAR. For 13 film measurement results, the average gamma passing rate was 94.1% using criteria of 3%/3 mm, 20% threshold and global gamma. The audit methodology was proved to be feasible and ready to be adopted by national dosimetry audit networks for local implementation
    corecore