151 research outputs found

    Modeling early recovery of physical function following hip and knee arthroplasty

    Get PDF
    BACKGROUND: Information on early recovery after arthroplasty is needed to help benchmark progress and make appropriate decisions concerning patient rehabilitation needs. The purpose of this study was to model early recovery of physical function in patients undergoing total hip (THA) and knee (TKA) arthroplasty, using physical performance and self-report measures. METHODS: A sample of convenience of 152 subjects completed testing, of which 69 (mean age: 66.77 ± 8.23 years) underwent THA and 83 (mean age: 60.25 ± 11.19 years) TKA. Postoperatively, patients were treated using standardized care pathways and rehabilitation protocols. Using a repeated measures design, patients were assessed at multiple time points over the first four postoperative months. Outcome measures included the Lower Extremity Function Scale (LEFS), the physical function subscale of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC PF), the 6 minute walk test (6 MWT), timed up and go test (TUG) and a timed stair test (ST). Average recovery curves for each of the measures were characterized using hierarchical linear modeling. Predictors of recovery were sequentially modeled after validation of the basic developmental models. RESULTS: Slopes of recovery were greater in the first 6 to 9 weeks with a second-degree polynomial growth term (weeks squared) providing a reasonable fit for the data over the study interval. Different patterns of recovery were observed between the self-report measures of physical function and the performance measures. In contrast to the models for the WOMAC PF and the LEFS, site of arthroplasty was a significant predictor (p = 0.001) in all of the physical performance measure models with the patients post TKA initially demonstrating higher function. Site of arthroplasty (p = 0.025) also predicted the rate of change for patients post THA and between 9 to 11 weeks after surgery, the THA group surpassed the function of the patients post TKA. CONCLUSION: Knowledge about the predicted growth curves will assist clinicians in referencing patient progress, and determining the critical time points for measuring change. The study has contributed further evidence to highlight the benefit of using physical performance measures to learn about the patients' actual level of disability

    Investigating Sodium Storage Mechanisms in Tin Anodes: A Combined Pair Distribution Function Analysis, Density Functional Theory and Solid-State NMR Approach

    Get PDF
    The alloying mechanism of high-capacity tin anodes for sodium-ion batteries is investigated using a combined theoretical and experimental approach. Ab initio random structure searching (AIRSS) and high-throughput screening using a species-swap method provide insights into a range of possible sodium-tin structures. These structures are linked to experiments using both average and local structure probes in the form of operando pair distribution function analysis, X-ray diffraction, and 23Na solid-state nuclear magnetic resonance (ssNMR), and ex situ 119Sn ssNMR. Through this approach, we propose structures for the previously unidentified crystalline and amorphous intermediates. The first electrochemical process of sodium insertion into tin results in the conversion of crystalline tin into a layered structure consisting of mixed Na/Sn occupancy sites intercalated between planar hexagonal layers of Sn atoms (approximate stoichiometry NaSn3). Following this, NaSn2, which is predicted to be thermodynamically stable by AIRSS, forms; this contains hexagonal layers closely related to NaSn3, but has no tin atoms between the layers. NaSn2 is broken down into an amorphous phase of approximate composition Na1.2Sn. Reverse Monte Carlo refinements of an ab initio molecular dynamics model of this phase show that the predominant tin connectivity is chains. Further reaction with sodium results in the formation of structures containing Sn-Sn dumbbells, which interconvert through a solid-solution mechanism. These structures are based upon Na5-xSn2, with increasing occupancy of one of its sodium sites commensurate with the amount of sodium added. ssNMR results indicate that the final product, Na15Sn4, can store additional sodium atoms as an off-stoichiometry compound (Na15+xSn4) in a manner similar to Li15Si4.This work was supported by STFCBatteries.org through the STFC Futures Early Career Award (J.M.S.). J.M.S. acknowledges funding from the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Vehicle Technologies, of the U.S. DOE under Contract no. DE-AC02-05CH11231, under the Batteries for Advanced Transportation Technologies (BATT) Program subcontract no. 7057154, and the European Commission under grant agreement no. 696656 (Graphene Flagship). P.K.A. acknowledges the School of the Physical Sciences of the University of Cambridge for funding through an Oppenheimer Research Fellowship and a Junior Research Fellowship from Gonville and Caius College, Cambridge. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement no. 655444 (O.P.). M.M. and A.J.M. acknowledge the support from the Winton Programme for the Physics of Sustainability. A.J.M. and C.J.P. were supported by Engineering and Physical Sciences Research Council (EPSRC) of the United Kingdom (Grant no. EP/G007489/2). C.J.P. is also supported by the Royal Society through a Royal Society Wolfson Research Merit award. Calculations were performed using the Archer facility of the UK national high performance computing service, for which access was obtained via the UKCP consortium and funded by EPSRC grant no. EP/K014560/1

    Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty

    Get PDF
    BACKGROUND: Physical performance measures play an important role in the measurement of outcome in patients undergoing hip and knee arthroplasty. However, many of the commonly used measures lack information on their psychometric properties in this population. The purposes of this study were to examine the reliability and sensitivity to change of the six minute walk test (6MWT), timed up and go test (TUG), stair measure (ST), and a fast self-paced walk test (SPWT) in patients with hip or knee osteoarthritis (OA) who subsequently underwent total joint arthroplasty. METHODS: A sample of convenience of 150 eligible patients, part of an ongoing, larger observational study, was selected. This included 69 subjects who had a diagnosis of hip OA and 81 diagnosed with knee OA with an overall mean age of 63.7 ± 10.7 years. Test-retest reliability, using Shrout and Fleiss Type 2,1 intraclass correlations (ICCs), was assessed preoperatively in a sub-sample of 21 patients at 3 time points during the waiting period prior to surgery. Error associated with the measures' scores and the minimal detectable change at the 90% confidence level was determined. A construct validation process was applied to evaluate the measures' abilities to detect deterioration and improvement at two different time points post-operatively. The standardized response mean (SRM) was used to quantify change for all measures for the two change intervals. Bootstrapping was used to estimate the 95% confidence intervals (CI) for the SRMs. RESULTS: The ICCs (95% CI) were as follows: 6MWT 0.94 (0.88,0.98), TUG 0.75 (0.51, 0.89), ST 0.90 (0.79, 0.96), and the SPWT 0.91 (0.81, 0.97). Standardized response means varied from .79 to 1.98, being greatest for the ST and 6MWT over the studied time intervals. CONCLUSIONS: The test-retest estimates of the 6MWT, ST, and the SPWT met the requisite standards for making decisions at the individual patient level. All measures were responsive to detecting deterioration and improvement in the early postoperative period

    Validity and reliability of telephone administration of the patient-specific functional scale for the assessment of recovery from snakebite envenomation

    Get PDF
    Objectives: Although more than 1.8 million people survive snakebite envenomation each year, their recovery is understudied. Obtaining long-term follow-up is challenging in both high- and low-resource settings. The Patient-Specific Functional Scale (PSFS) is an easily administered, well-accepted patient-reported outcome that is validated for assessing limb recovery from snakebite envenomation. We studied whether the PSFS is valid and reliable when administered by telephone. Methods: This is a secondary analysis of data from a randomized clinical trial. We analyzed the results of PSFS collected in-person on days 3, 7, 14, 21, and 28 and by telephone on days 10, 17, and 24. We assessed the following scale psychometric properties: (a) content validity (ceiling and floor effects), (b) internal structure and consistency (Cronbach’s alpha), and (c) temporal and external validity using Intraclass Correlation Coefficient (ICC). Temporal stability was assessed using Spearman’s correlation coefficient and agreement between adjacent in-person and telephonic assessments with Cohen’s kappa. Bland Altman analysis was used to assess differential bias in low and high score results. Results: Data from 74 patients were available for analysis. Floor effects were seen in the early post-injury time points (median: 3 (IQR: 0, 5) at 3 days post-enrollment) and ceiling effects in the late time points (median: 9 (IQR: 8, 10). Internal consistency was good to excellent with both in-person (Cronbach α: 0.91 (95%CI 0.88, 0.95)) and telephone administration (0.81 (0.73, 0.89). Temporal stability was also good (ICC: 0.83 (0.72, 0.89) in-person, 0.80 (0.68, 0.88) telephone). A strong linear correlation was found between in-person and telephone administration (Spearman’s �: 0.83 (CI: 0.78, 0.84), consistency was assessed as excellent (Cohen’s κ 0.81 (CI: 0.78, 0.84), and Bland Altman analysis showed no systematic bias. Conclusions: Telephone administration of the PSFS provides valid, reliable, and consistent data for the assessment of recovery from snakebite envenomation

    Minimum detectable and minimal clinically important changes for pain in patients with nonspecific neck pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The minimal detectable change (MDC) and the minimal clinically important changes (MCIC) have been explored for nonspecific low back pain patients and are similar across different cultural settings. No data on MDC and MCIC for pain severity are available for neck pain patients. The objectives of this study were to estimate MDC and MCIC for pain severity in subacute and chronic neck pain (NP) patients, to assess if MDC and MCIC values are influenced by baseline values and to explore if they are different in the subset of patients reporting referred pain, and in subacute versus chronic patients.</p> <p>Methods</p> <p>Subacute and chronic patients treated in routine clinical practice of the Spanish National Health Service for neck pain, with or without pain referred to the arm, and a pain severity ≥ 3 points on a pain intensity number rating scale (PI-NRS), were included in this study. Patients' own "global perceived effect" over a 3 month period was used as the external criterion. The minimal detectable change (MDC) was estimated by means of the standard error of measurement in patients who self-assess as unchanged. MCIC were estimated by the mean value of change score in patients who self-assess as improved (mean change score, MCS), and by the optimal cutoff point in receiver operating characteristics curves (ROC). The effect on MDC and MCIC of initial scores, duration of pain, and existence of referred pain were assessed.</p> <p>Results</p> <p>658 patients were included, 487 of them with referred pain. MDC was 4.0 PI-NRS points for neck pain in the entire sample, 4.2 for neck pain in patients who also had referred pain, and 6.2 for referred pain. MCS was 4.1 and ROC was 1.5 for referred and for neck pain, both in the entire sample and in patients who also complained of referred pain. ROC was lower (0.5 PI-NRS points) for subacute than for chronic patients (1.5 points). MCS was higher for patients with more intense baseline pain, ranging from 2.4 to 4.9 PI-NRS for neck pain and from 2.4 to 5.3 for referred pain.</p> <p>Conclusion</p> <p>In general, improvements ≤ 1.5 PI-NRS points could be seen as irrelevant. Above that value, the cutoff point for clinical relevance depends on the methods used to estimate MCIC and on the patient's baseline severity of pain. MDC and MCIC values in neck pain patients are similar to those for low back pain and other painful conditions.</p

    The Extended Learning Curve for Laparoscopic Fundoplication: A Cohort Analysis Of 400 Consecutive Cases

    Get PDF
    Many studies have looked at the learning curve associated with laparoscopic Nissen fundoplication (LNF) in a given institution. This study looks at the learning curve of a single surgeon with a large cohort of patients over a 10-year period. Prospective data were collected on 400 patients undergoing laparoscopic fundoplication for over 10 years. The patients were grouped consecutively into cohorts of 50 patients. The operating time, the length of postoperative hospital stay, the conversion rate to open operation, the postoperative dilatation rate, and the reoperation rate were analyzed. Results showed that the mean length of operative time decreased from 143 min in the first 50 patients to 86 min in the last 50 patients. The mean postoperative length of hospital stay decreased from 3.7 days initially to 1.2 days latterly. There was a 14% conversion to open operation rate in the first cohort compared with a 2% rate in the last cohort. Fourteen percent of patients required reoperation in the first cohort and 6% in the last cohort. Sixteen percent required postoperative dilatation in the first cohort. None of the last 150 patients required dilatation. In conclusion, laparoscopic fundoplication is a safe and effective operation for patients with gastroesophageal reflux disease. New techniques and better instrumentation were introduced in the early era of LNF. The learning curve, however, continues well beyond the first 20 patients

    Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?

    Get PDF
    BACKGROUND: Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to detect valid change when pain and function display different profiles of change. This study examined the etiology of the WOMAC's physical function subscale's limited ability to detect change in the presence of discordant changes for pain and function. We hypothesized that the duplication of some items on the WOMAC's pain and function subscales contributed to this shortcoming. METHODS: Two eight-item physical function scales were abstracted from the WOMAC's 17-item physical function subscale: one contained activities and themes that were duplicated on the pain subscale (SIMILAR-8); the other version avoided overlapping activities (DISSIMILAR-8). Factorial validity of the shortened measures was assessed on 310 patients awaiting hip or knee arthroplasty. The shortened measures' abilities to detect change were examined on a sample of 104 patients following primary hip or knee arthroplasty. The WOMAC and three performance measures that included activity specific pain assessments – 40 m walk test, stair test, and timed-up-and-go test – were administered preoperatively, within 16 days of hip or knee arthroplasty, and at an interval of greater than 20 days following the first post-surgical assessment. Standardized response means were used to quantify change. RESULTS: The SIMILAR-8 did not demonstrate factorial validity; however, the factorial structure of the DISSIMILAR-8 was supported. The time to complete the performance measures more than doubled between the preoperative and first postoperative assessments supporting the theory that lower extremity functional status diminished over this interval. The DISSIMILAR-8 detected this deterioration in functional status; however, no significant change was noted for the SIMILAR-8. The WOMAC pain scale demonstrated a slight reduction in pain and the performance specific pain measures did not reflect a change in pain. All measures showed substantial improvement over the second assessment interval. CONCLUSIONS: These findings support the hypothesis that activity overlap on the pain and function subscales plays a causal role in limiting the WOMAC physical function subscale's ability to detect change

    Does reductive metabolism predict response to tirapazamine (SR 4233) in human non-small-cell lung cancer cell lines?

    Get PDF
    The bioreductive drug tirapazamine (TPZ, SR 4233, WIN 59075) is a lead compound in a series of potent cytotoxins that selectively kill hypoxic rodent and human solid tumour cells in vitro and in vivo. Phases II and III trials have demonstrated its efficacy in combination with both fractionated radiotherapy and some chemotherapy. We have evaluated the generality of an enzyme-directed approach to TPZ toxicity by examining the importance of the one-electron reducing enzyme NADPH:cytochrome P450 reductase (P450R) in the metabolism and toxicity of this lead prodrug in a panel of seven human non-small-cell lung cancer cell lines. We relate our findings on TPZ sensitivity in these lung lines with our previously published results on TPZ sensitivity in six human breast cancer cell lines (Patterson et al (1995) Br J Cancer 72: 1144–1150) and with the sensitivity of all these cell types to eight unrelated cancer chemotherapeutic agents with diverse modes of action. Our results demonstrate that P450R plays a significant role in the activation of TPZ in this panel of lung lines, which is consistent with previous observations in a panel of breast cancer cell lines (Patterson et al (1995) Br J Cancer 72: 1144–1150; Patterson et al (1997) Br J Cancer 76: 1338–1347). However, in the lung lines it is likely that it is the inherent ability of these cells to respond to multiple forms of DNA damage, including that arising from P450R-dependent TPZ metabolism, that underlies the ultimate expression of toxicity. © 1999 Cancer Research Campaig

    The reliability of side to side measurements of upper extremity activity levels in healthy subjects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In both clinical and occupational settings, ambulatory sensors are becoming common for assessing all day measurements of arm motion. In order for the motion of a healthy, contralateral side to be used as a control for the involved side, the inherent side to side differences in arm usage must be minimal. The goal of the present study was to determine the reliability of side to side measurements of upper extremity activity levels in healthy subjects.</p> <p>Methods</p> <p>Thirty two subjects with no upper extremity pathologies were studied. Each subject wore a triaxial accelerometer on both arms for three and a half hours. Motion was assessed using parameters previously reported in the literature. Side to side differences were compared with the intraclass correlation coefficient, standard error of the mean, minimal detectable change scores and a projected sample size analysis.</p> <p>Results</p> <p>The variables were ranked based on their percentage of minimal detectable change scores and sample sizes needed for paired t-tests. The order of these rankings was found to be identical and the top ranked parameters were activity counts per hour (MDC% = 9.5, n = 5), jerk time (MDC% = 15.8, n = 8) and percent time above 30 degrees (MDC% = 34.7, n = 9).</p> <p>Conclusions</p> <p>In general, the mean activity levels during daily activities were very similar between dominant and non-dominant arms. Specifically, activity counts per hour, jerk time, and percent time above 30 degrees were found to be the variables most likely to reveal significant difference or changes in both individuals and groups of subjects. The use of ambulatory measurements of upper extremity activity has very broad uses for occupational assessments, musculoskeletal injuries of the shoulder, elbow, wrist and hand as well as neurological pathologies.</p
    corecore