    Post space debridement in oval-shaped canals: The use of a new ultrasonic tip with oval section

    No full text
    This study evaluates the effect on post space debridement in oval-shaped canals of an experimental ultrasonic tip with oval section (Satelec) compared with a circular ultrasonic tip (KaVo). Thirty teeth with an oval-shaped canal were endodontically treated and obturated and then randomly divided into 3 groups (n = 10) according to the procedure used for post space debridement: Satelec tip, Largo #2 drill + KaVo file, and Largo #2 drill + water. Debris and dentin tubules were evaluated by assigning scores to scanning electron microscope post spaces images; lower scores corresponded to fewer debris and higher number of open tubules. The Satelec group showed significantly lower debris and open tubules scores than KaVo group (p < .05) and control group (p < .05), which differed significantly between each other (p < .05). Also the debris and open tubules scores in different post space regions differed significantly among the experimental groups (p < .001). The oval ultrasonic tip resulted in a better post space debridement than a circular ultrasonic tip in oval-shaped canals

    Influence of ultrasound application on inlays luting with self-adhesive resin cements

    No full text
    The study was aimed at assessing the influence of the cement manipulation and ultrasounds application on the bonding potential of self-adhesive resin cements to dentin by microtensile bond strength testing and microscopic observations of the interface. Fifty-six standardized mesio-occlusal class II cavities were prepared in extracted third molars. Class II inlays were made using the nano-hybrid resin composite Gradia Forte (GC Corp, Tokyo, Japan), following the manufacturer's instruction. The sample was randomly divided into two groups (n = 28) according to the luting technique. Half of the specimens were luted under a static seating pressure (P), while the other ones were cemented under vibration (V). The inlays were luted using the following self-adhesive resin cements: G-Cem (G, GC Corp., Tokyo, Japan) Automix (GA) and Capsule (GC); RelyX Unicem (RU, 3 M ESPE, Seefeld, Germany) Clicker (RUC) and Aplicap (RUA). Microtensile sticks and specimens for scanning electron microscope (SEM) observations were obtained from the luted teeth. The interfacial strengths measured for the cements under static pressure or ultrasonic vibration were [median (interquartile range)]: GC/V 4 (2.3-7.9); GC/P 6.8 (4.1-10.1); GA/V 3 (1.9-6.7); GA/P 1.9 (0-5.1); RUC/V 6.6 (4.6-9.8); RUC/P 4.1 (1.8-6.4); RUA/V 6.2 (2.4-10.4); RUA/P 3.4 (0-5.4). The cement formulation influenced dentin bond strength of G. RU bond strength was affected by the luting technique. SEM analysis revealed a homogeneous structure and reduced porosities for both cements as a result of ultrasonic vibration. RU benefited from the application of ultrasounds, while GC achieved higher bond strengths than GA

    Push-out Bond Strength of Fiber Posts Luted with Unfilled Resin Cement

    No full text
    Purpose: The study evaluates the behavior of different adhesive systems and resin cements in fiber post placement, with the intent to clarify the possible role of unfilled resin as a luting material for fiber posts. Materials and Methods: Two luting agents (Dual-Link and Unfilled Resin) for cementing fiber posts into root canals were applied either with All-Bond 2 or One-Step Plus, or without an adhesive system, and challenged with the push-out test. Slices of roots restored with posts were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under SEM. Results: Push-out strength was significantly influenced by the luting agent (p < 0.05), but not by the bonding strategy (p > 0.05). The best results were obtained in combination with Unfilled Resin with One-Step Plus. Dual-Link groups failed mainly cohesively within the cement, while Unfilled Resin demonstrated more adhesive fracture at the post interface. Conclusion: The results of this study support the hypothesis that adhesive unfilled resin application is essential for achieving high bond strength to radicular dentin
    corecore