112,575 research outputs found
How Well Do We Know the Beta-Decay of 16N and Oxygen Formation in Helium Burning
We review the status of the 12C(a,g)16O reaction rate, of importance for
stellar processes in a progenitor star prior to a super-nova collapse. Several
attempts to constrain the p-wave S-factor of the 12C(a,g)16O reaction at Helium
burning temperatures (200 MK) using the beta-delayed alpha-particle emission of
16N have been made, and it is claimed that this S-factor is known, as quoted by
the TRIUMF collaboration. In contrast reanalyses (by G.M. hale) of all thus far
available data (including the 16N data) does not rule out a small S-factor
solution. Furthermore, we improved our previous Yale-UConn study of the beta-
delayed alpha-particle emission of \n16 by improving our statistical sample (by
more than a factor of 5), improving the energy resolution of the experiment (by
20%), and in understanding our line shape, deduced from measured quantities.
Our newly measured spectrum of the beta-delayed alpha-particle emission of 16N
is not consistent with the TRIUMF('94) data, but is consistent with the
Seattle('95) data, as well as the earlier (unaltered !) data of Mainz('71). The
implication of this discrepancies for the extracted astrophysical p-wave
s-factor is briefly discussed.Comment: 6 pages, 4 figures, Invited Talk, Physics With Radioactive Beams,
Puri, India, Jan. 12-17, 1998, Work Supported by USDOE Grant No.
DE-FG02-94ER4087
Inclusion agglomeration in electrified molten metal: thermodynamic consideration
The effect of electric current on inclusion agglomeration in molten metal has been investigated. It is found that the agglomeration is dependent on the electric current density, distance between inclusions and orientation of electric field. Electric current retards the agglomeration unless two inclusions are aligned along or closely to the current flow streamlines and the distance between inclusions is less than a critical value. The mechanism is also validated in the computation of cluster agglomeration. The numerical results provide a comprehensive indication for the current-induced inclusion removal and current-induced inclusion elongation. When the inclusions are in long-thin shape, the calculation predicts the current-induced microstructure alignment and current-induced microstructure refinement phenomena
On several families of elliptic curves with arbitrary large Selmer groups
In this paper, we calculate the Selmer groups
S^{(\phi)} (E / \Q) and S^{(\hat{\varphi})} (E^{\prime} / \Q) of elliptic
curves via descent theory
(see [S, Chapter X]), in particular, we obtain that the Selmer groups of
several families of such elliptic curves can be arbitrary large.Comment: 22 page
Recommended from our members
Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China
Increasing roof albedo (using a “cool” roof) and night ventilation are passive cooling technologies that can reduce the cooling loads in buildings, but existing studies have not comprehensively explored the potential benefits of integrating these two technologies. This study combines an experiment in the summer and transition seasons with an annual simulation so as to evaluate the thermal performance, energy savings and thermal comfort improvement that could be obtained by coupling a cool roof with night ventilation. A holistic approach integrating sensitivity analysis and multi-objective optimization is developed to explore key design parameters (roof albedo, night ventilation air change rate, roof insulation level and internal thermal mass level) and optimal design options for the combined application of the cool roof and night ventilation. The proposed approach is validated and demonstrated through studies on a six-storey office building in Xiamen, a cooling-dominated city in southeast China. Simulations show that combining a cool roof with night ventilation can significantly decrease the annual cooling energy consumption by 27% compared to using a black roof without night ventilation and by 13% compared to using a cool roof without night ventilation. Roof albedo is the most influential parameter for both building energy performance and indoor thermal comfort. Optimal use of the cool roof and night ventilation can reduce the annual cooling energy use by 28% during occupied hours when air-conditioners are on and reduce the uncomfortable time slightly during occupied hours when air-conditioners are off
Recommended from our members
Effects of natural soiling and weathering on cool roof energy savings for dormitory buildings in Chinese cities with hot summers
Roofs with high-reflectance (solar reflectance) coating, commonly known as cool roofs, can stay cool in the sun, thereby reducing building energy consumption and mitigating the urban heat island. However, chemical-physical degradation and biological growth can decrease their solar reflectance and the ability to save energy. In this study, the solar spectral reflectance of 12 different roofing products with an initial albedo of 0.56–0.90 was measured before exposure and once every three months over 32 months. Specimens were exposed on the roofs of dormitory buildings in Xiamen and Chengdu, each major urban areas with hot summers. The albedos of high and medium-lightness coatings stabilized in the ranges 0.45–0.62 and 0.36–0.59 in both cities, respectively. This study yielded albedo loss exceeded those reported in the latest Chinese standard by 0.08–0.15. Finally, DesignBuilder (EnergyPlus) simulations estimate that a new cool roof with albedo 0.78 on a six-story dormitory building will yield annual site energy savings (heating and cooling) for the top floor, which are 8.01 kWh/m2 (24.2%) and 9.12 kWh/m2 (26.3%) per unit floor area in Xiamen and Chengdu, respectively; while an aged cool roof with albedo 0.45 and 0.56 will yield the annual savings by 5.12 kWh/m2 (15.4%) and 2.47 kWh/m2 (10.5%) in these two cities
- …