26 research outputs found

    Performance evaluation of several well-known and new scintillators for MeV X-ray imaging

    Get PDF
    International audienceDigital X-ray imaging systems for MeV range photon beams are based on a combination of a scintillator screen and either a camera or an amorphous silicon array. To limit dose rate on electronics and enhance imaging device lifetime, the scintillator screen is mirror-coupled to the camera. Performances of such devices are a compromise between exposure time and spatial resolution. These technical characteristics are especially scintillator dependent. In this paper, we present a performance evaluation of six different scintillators with a 9 MeV Bremsstrahlung X-ray source. The tested scintillators are composed of one micro-structured CsI(Tl) scintillator, two phosphor (GOS) screens and three transparent scintillators. These scintillators present a wide range of density, thickness and conversion efficiency. Each scintillator's performance is assessed based on the combination of light output (ADU number) and modulation transfer function (spatial resolution) obtained. The results are helpful to guide design and engineering of high energy imaging devices adapted to specific requirements

    Performance assessment of amplification and discrimination electronic devices for passive neutron measurements

    No full text
    The knowledge of the fissile material mass is a key challenge to enhance radioactive waste management and to ensure a high level of safety in nuclear industry. Data is analyzed according to the principles of the neutron measurement techniques. As proportional counters filled with 3He gas display high neutron detection efficiency and a good gamma-ray discrimination, they are the reference detector for passive neutron coincidence counting. A charge preamplifier or a current amplifier, depending on applications, collects the electric pulse produced by neutron interaction in the 3He gas and a threshold discriminator produces a logic pulse used for neutron counting. This paper describes the performance assessment of different commercially available electronics from Mirion Technologies, Precision Data Technology (PDT), Mesytec, as well as MONACO electronics originally developed by CEA LIST for fission chamber measurements in experimental reactors. Comparative passive neutron measurements are carried out with these electronics at CEA/DEN Nuclear Measurement Laboratory in Cadarache. Overall, PDT and Mesytec electronics show similar detection efficiency as the ACH-NA98 charge amplifier, which is commonly used in our laboratory for such applications. However, MONACO electronics have a lower detection efficiency, similar to Mirion 7820 current amplifier used in specific high-count rate applications. An optimisation of MONACO settings would probably be necessary to adapt to 3He counters instead of fission chambers

    Study of gamma-ray background noise for radioactive waste drum characterization with plastic scintillators

    No full text
    In the framework of the radioactive waste drum characterization using neutron coincidence counting, the Nuclear Measurement Laboratory of CEA Cadarache is studying plastic scintillators as an alternative to ideal but costly 3He gas proportional counters. Plastic scintillators are at least 5 times cheaper for the same detection efficiency, and in addition, they detect fast neutrons about three orders of magnitude faster than 3He detectors. However, they are sensitive to gamma rays, which implies the necessity to identify precisely gamma background sources that may affect the useful signal. This paper presents a detailed analysis of the gamma-ray spectrum of a radioactive waste drum containing glove box filters contaminated by plutonium dioxide. Gamma emissions accompanying inelastic scattering (n,n’) and (α,n) reactions that can lead to neutron-gamma coincidences parasitizing useful coincidences from plutonium spontaneous fissions are identified. Some of these parasitic gamma rays having energies up to several MeV, we plan to reject high-energy scintillator pulses with an electronics rejection threshold above 1 MeV, which should preserve the major part of useful fission neutron pulses

    Study of gamma-ray background noise for radioactive waste drum characterization with plastic scintillators

    Get PDF
    In the framework of the radioactive waste drum characterization using neutron coincidence counting, the Nuclear Measurement Laboratory of CEA Cadarache is studying plastic scintillators as an alternative to ideal but costly 3He gas proportional counters. Plastic scintillators are at least 5 times cheaper for the same detection efficiency, and in addition, they detect fast neutrons about three orders of magnitude faster than 3He detectors. However, they are sensitive to gamma rays, which implies the necessity to identify precisely gamma background sources that may affect the useful signal. This paper presents a detailed analysis of the gamma-ray spectrum of a radioactive waste drum containing glove box filters contaminated by plutonium dioxide. Gamma emissions accompanying inelastic scattering (n,n’) and (α,n) reactions that can lead to neutron-gamma coincidences parasitizing useful coincidences from plutonium spontaneous fissions are identified. Some of these parasitic gamma rays having energies up to several MeV, we plan to reject high-energy scintillator pulses with an electronics rejection threshold above 1 MeV, which should preserve the major part of useful fission neutron pulses

    Sorting fission from parasitic coincidences of neutrons and gamma rays in plastic scintillators using particle times of flight

    No full text
    This work addresses the use of plastic scintillators as an alternative to 3He detectors for radioactive waste drum characterization. The time response of scintillators is three orders of magnitude faster than that of gas proportional counters and they offer similar neutron detection efficiency at lower cost. However, they are sensitive to gamma rays and the commonly used Pulse Shape Discrimination technique is not possible with basic PVT scintillators. This paper reports on an innovative data processing technique allowing to extract spontaneous fission events from parasitic coincidences, such as those from the (α,n) reactions accompanied by correlated gamma rays or from pure gamma-ray sources emitting correlated radiations. The proposed approach makes advantage of differences in the pulse detection times recorded in measurements with the 252Cf, AmBe and 60Co sources. More precisely, a 2D histogram of time delays between the detected 2nd and 1st pulses, on the x-axis, and between the 3rd and 2nd pulses, on the y-axis, is found to allow for selection of a region of interest most relevant to spontaneous fission events.</jats:p
    corecore