1,399 research outputs found

    Transparent and Flexible Thin Film Electroluminescent Devices Using HiTUS Deposition and Laser Processing Fabrication

    Get PDF
    Highly transparent thin film electroluminescent structures offering excellent switch on characteristics, high luminance and large break-down voltages have been deposited onto glass and flexible polymeric materials with no substrate heating using high target utilization sputtering. Deposition of ZnS:Mn as the active light emitting layer and Y2O3,Al2O3,Ta2O5, and HfO2 as dielectric materials arranged in single and multiple layer configurations were investigated. Devices incorporating Al2O3,HfO2 quadruple layers demonstrate the highest attainable luminance at low threshold voltage. Single pulse excimer laser irradiation of the phosphor layer prior to deposition of the top dielectric layer enhanced the luminance of the devices. The devices fabricated on glass and polymeric substrates exhibited a maximum luminance of 500 and 450 cdm−2 when driven at 270 VRMS and 220 VRMS, respectively, with a 1.0 kHz sine wave

    Low temperature remote plasma sputtering of indium tin oxide for flexible display applications

    Get PDF
    Tin doped indium oxide (ITO) has been directly deposited onto a variety of flexible materials by a reactive sputtering technique that utilises a remotely generated, high density plasma. This technique, known as high target utilisation sputtering (HiTUS), allows for the high rate deposition of good quality ITO films onto polymeric materials with no substrate heating or post deposition annealing. Coatings with a resistivity of 3.8 ×10−4 Ωcm and an average visible transmission of greater than 90% have been deposited onto PEN and PET substrate materials at a deposition rate of 70 nm/min. The electrical and optical properties are retained when the coatings are flexed through a 1.0 cm bend radius, making them of interest for flexible display applications

    The management of tetanus in adults in an intensive care unit in Southern Vietnam

    Get PDF
    Background: Tetanus remains common in many low- and middle-income countries (LMICs) yet the evidence base guiding management of this disease is extremely limited, particularly with respect to contemporary management options. Sharing knowledge about practice may facilitate improvement in outcomes elsewhere. Methods: We describe clinical interventions and outcomes of 180 adult patients ≥16 years-old with tetanus enrolled in prospective observational studies at a specialist infectious diseases hospital in Southern Vietnam. Patients were treated according to a holistic management protocol encompassing wound-care, antitoxin, antibiotics, symptom control, airway management, nutrition and de-escalation criteria. Results: Mortality rate in our cohort was 2.8%, with 90 (50%) patients requiring mechanical ventilation for a median 16 [IQR 12-24] days. Median [IQR] duration of ICU stay was 15 [8-23] days. Autonomic nervous system dysfunction occurred in 45 (25%) patients. Hospital acquired infections occurred in 77 (43%) of patients. Conclusion: We report favourable outcomes for patients with tetanus in a single centre LMIC ICU, treated according to a holistic protocol. Nevertheless, many patients required prolonged intensive care support and hospital acquired infections were common

    Evaluation of the MODS Culture Technique for the Diagnosis of Tuberculous Meningitis

    Get PDF
    Tuberculous meningitis (TBM) is a devastating condition. The rapid instigation of appropraite chemotherapy is vital to reduce morbidity and mortality. However rapid diagnosis remains elusive; smear microscopy has extremely low sensitivity on cerebrospinal fluid (CSF) in most laboratories and PCR requires expertise with advanced infrastructure and has sensitivity of only around 60% under optimal conditions. Neither technique allows for the microbiological isolation of M. tuberculosis and subsequent drug susceptibility testing. We evaluated the recently developed microscopic observation drug susceptibility (MODS) assay format for speed and accuracy in diagnosing TBM.Two hundred and thirty consecutive CSF samples collected from 156 patients clinically suspected of TBM on presentation at a tertiary referal hospital in Vietnam were enrolled into the study over a five month period and tested by Ziehl-Neelsen (ZN) smear, MODS, Mycobacterial growth Indicator tube (MGIT) and Lowenstein-Jensen (LJ) culture. Sixty-one samples were from patients already on TB therapy for >1day and 19 samples were excluded due to untraceable patient records. One hundred and fifty samples from 137 newly presenting patients remained. Forty-two percent (n = 57/137) of patients were deemed to have TBM by clinical diagnostic and microbiological criteria (excluding MODS). Sensitivity by patient against clinical gold standard for ZN smear, MODS MGIT and LJ were 52.6%, 64.9%, 70.2% and 70.2%, respectively. Specificity of all microbiological techniques was 100%. Positive and negative predictive values for MODS were 100% and 78.7%, respectively for HIV infected patients and 100% and 82.1% for HIV negative patients. The median time to positive was 6 days (interquartile range 5-7), significantly faster than MGIT at 15.5 days (interquartile range 12-24), and LJ at 24 days (interquartile range 18-35 days) (P<0.01).We have shown MODS to be a sensitive, rapid technique for the diagnosis of TBM with high sensitivity, ease of performance and low cost (0.53 USD/sample)

    Effect of dynamic stall on the aerodynamics of vertical-axis wind turbines

    Get PDF
    Accurate simulations of the aerodynamic performance of vertical-axis wind turbines pose a significant challenge for computational fluid dynamics methods. The aerodynamic interaction between the blades of the rotor and the wake that is produced by the blades requires a high-fidelity representation of the convection of vorticity within the wake. In addition, the cyclic motion of the blades induces large variations in the angle of attack on the blades that can manifest as dynamic stall. The present paper describes the application of a numerical model that is based on the vorticity transport formulation of the Navier–Stokes equations, to the prediction of the aerodynamics of a verticalaxis wind turbine that consists of three curved rotor blades that are twisted helically around the rotational axis of the rotor. The predicted variation of the power coefficient with tip speed ratio compares very favorably with experimental measurements. It is demonstrated that helical blade twist reduces the oscillation of the power coefficient that is an inherent feature of turbines with non-twisted blade configurations

    Evaluation of the ability of a 2D ionisation chamber array and an EPID to detect systematic delivery errors in IMRT plans

    Get PDF
    Two clinical intensity modulated radiotherapy plans were selected. Eleven plan variations were created with systematic errors introduced: Multi-Leaf Collimator (MLC) positional errors with all leaf pairs shifted in the same or the opposite direction, and collimator rotation offsets. Plans were measured using an Electronic Portal Imaging Device (EPID) and an ionisation chamber array. The plans were evaluated using gamma analysis with different criteria. The gamma pass rates remained around 95% or higher for most cases with MLC positional errors of 1 mm and 2 mm with 3%/3mm criteria. The ability of both devices to detect delivery errors was similar

    Freezing of Ram Semen Using Glycerol-Free Extenders

    Get PDF
    A series of five major experiments was conducted to determine the possibility of freezing ram semen using extenders excluding glycerol which has been found to have adverse effects on the acrosome membrane of ram spermatozoa and to result in reduced fertility. Semen samples were obtained from 6 rams (3 Merinos: M and 3 Coopworths: C) by AV. Two criteria were used to determine semen quality after freezing namely, percentage of sperm motility and acrosome integrity. Sperm motility was determined by the conventional microscopic method and acrosome integrity was determined by a 'sperm bound amidase assay'
    corecore